Choising the alternative conditions for the continuity of the work of the nitrate-selective electrode

اختيار الشروط البديلة لاستمرارية عمل مسرى النترات الانتقائي

1153   0   7   0 ( 0 )
 Publication date 2017
and research's language is العربية
 Created by Shamra Editor




Ask ChatGPT about the research

Due to the absence of operational requirements and its unidentified solutions ,this study presented definition alternative analytical and technical conditions for the continuation of nitrate-selective electrode working. Many electrolytes were tested (ammonium sulfate, ammonium acetate and ammonium chloride). The technical and analytical conditions shows that the best response which give the Nernst slope of the electrode had been obtained by adding 0.5ml of ammonium sulfate (3mol / l), and the response time was 20sec, by the time that values stabilized for 15sec. The study of pH effect on the electrode response also showed that electrode works within the range (2-8) of pH and that the best response was at pH = 5.5 by using acetic acid-sodium acetate buffer. The effect of temperature on the potential electrode was studied ,it showed that the Nernest electrode response realized within the range (18-37) C0of temperature.While Studying the effect of some interfering ions such as (OH-, HCO3 -, CO3 2-,Cl-,NO2 -) on the work of the electrode showed low values of the coefficient of selectivity, which did not exceed 3×10-2 that the electrode was not affected by the presence of these ions. The chosen conditions were experimented on standard solutions, which showed that the electrode is working within the range (10-4-10-1) mol / l of concentrations. When the concentrations was about 10-5mol/l or less than that, it was necessary to soak the electrode in solution which has low concentration for at least one hour, and diluted the taken volumes ten times . These technical and analytical conditions was applied on standard solutions and environmental samples(water), which showed the accuracy ,correctly and authenticity of the measurements.


Artificial intelligence review:
Research summary
تناولت الدراسة إيجاد شروط بديلة تحليلية وتقنية لاستمرار عمل مسرى النترات الانتقائي، نظراً لغياب الشروط التشغيلية والمحاليل المرفقة بها مجهولة الهوية. جرى العمل على اختبار أكثر من الكتروليت مثل كبريتات الأمونيوم، خلات الأمونيوم وكلوريد الأمونيوم. وتبين من خلال الشروط التقنية والتحليلية أن إضافة كبريتات الأمونيوم بتركيز 3mol/1 أعطت أفضل استجابة وميل نرنستي للمسرى كما أعطت زمن تجاوب 20 ثانية وبقيت القيم ثابتة لمدة 15 ثانية. كما بينت دراسة مجال الـ pH أن المسرى يعمل ضمن مجال (8-2)pH وأن أفضل استجابة كانت عند 5.5 بوجود المحلول المنظم حمض الخل-خلات الصوديوم. دُرس تأثير درجة الحرارة على كمون المسرى ووجد أن الاستجابة نرنستية عند مجال درجة حرارة (37-18) درجة مئوية. أما عند دراسة إعاقة بعض الأيونات مثل (OH، HCO3، CO3، CI، NO2) على عمل المسرى فقد بينت القيم المنخفضة لمعامل الانتقائية الذي لم يتعد 3×10-2 عدم تأثر المسرى بوجود هذه الأيونات. جُربت الشروط المختارة على محاليل عيارية، فلُحظ أن المسرى يعمل ضمن مجال تراكيز (10-4-10)mol/l، أما عند التراكيز من مرتبة (10-5mol/l) فما دون كان لابد من نقع المسرى بمحلول ذي تركيز منخفض لمدة ساعة على الأقل وتمديد الحجوم المأخوذة عشر مرات. طبقت هذه الشروط التقنية والتحليلية على محاليل عيارية وواقعية (عينات مائية)، فأعطت نتائج قياس دقيقة وصحيحة وذات مصداقية.
Critical review
دراسة نقدية: تقدم هذه الدراسة مساهمة هامة في مجال التحليل الكيميائي والبيئي من خلال تحسين شروط عمل مسرى النترات الانتقائي. ومع ذلك، يمكن ملاحظة بعض النقاط التي قد تحتاج إلى مزيد من التوضيح أو التحسين. أولاً، لم يتم التطرق بشكل كافٍ إلى تأثير التداخلات المحتملة من الأيونات الأخرى الموجودة في العينات البيئية الواقعية، والتي قد تؤثر على دقة القياسات. ثانياً، قد يكون من المفيد تقديم مزيد من التفاصيل حول كيفية اختيار التراكيز المثلى للإلكتروليتات المختلفة، بالإضافة إلى تحليل أكثر شمولية للنتائج الإحصائية لضمان موثوقية النتائج. وأخيراً، يمكن أن تكون الدراسة أكثر شمولاً إذا تم تضمين تطبيقات عملية إضافية في مجالات أخرى مثل الزراعة والصناعة، مما يعزز من قيمة البحث ويزيد من نطاق استخدامه.
Questions related to the research
  1. ما هي أفضل الشروط التشغيلية لمسرى النترات الانتقائي التي توصلت إليها الدراسة؟

    أفضل الشروط التشغيلية التي توصلت إليها الدراسة هي استخدام كبريتات الأمونيوم بتركيز 3mol/1، مجال pH بين 2-8 مع أفضل استجابة عند pH=5.5 باستخدام محلول منظم حمض الخل-خلات الصوديوم، ومجال درجة حرارة بين 18-37 درجة مئوية.

  2. ما هو تأثير درجة الحرارة على استجابة مسرى النترات الانتقائي؟

    وجدت الدراسة أن استجابة مسرى النترات الانتقائي نرنستية ضمن مجال درجة حرارة بين 18-37 درجة مئوية، مما يعني أن المسرى يعمل بكفاءة ضمن هذا المجال الحراري.

  3. كيف تؤثر الأيونات المعيقة على عمل مسرى النترات الانتقائي؟

    بينت الدراسة أن الأيونات المعيقة مثل OH، HCO3، CO3، CI، NO2 لها تأثير منخفض على عمل مسرى النترات الانتقائي، حيث لم يتعد معامل الانتقائية 3×10-2، مما يدل على أن المسرى غير متأثر بشكل كبير بوجود هذه الأيونات.

  4. ما هي الإجراءات المتبعة عند قياس تراكيز منخفضة جداً من النترات؟

    عند قياس تراكيز منخفضة جداً من النترات (من مرتبة 10-5mol/l فما دون)، يجب نقع المسرى بمحلول ذي تركيز منخفض لمدة ساعة على الأقل وتمديد الحجوم المأخوذة عشر مرات لضمان دقة القياس.

Keywords

References used
COMELIA.M; PETRU.N;MIHAELA.C; LAVINIA.L;IOAN.U; GIANNIN.M. Studies Regarding the Ground Water Pollution in a Rural Area. Chem.Bull, Romania, 2006, Vol.51(65),1- 2, 75-78
SIMON.V; CAMPEANU.GH; VASILE.G; ARTIMON.M; CATANA.L; NEGOTTA.M. Nitrate and nitrite accumulation in tomatoes and derived products.Bucharest University, Romania, 2008, Vol. 3, No.4, pp. 3785-3790
IARC Working Group .Ingested Nitrate and Nitrite, and Cyanobacterial PeptideToxins. World health organization international agency for research on, France, 2010, Vol94
rate research

Read More

This research studying the effect of the most important analytical and technical conditions on the voltammetric curves of lead and cadmium in order to choose the optimal conditions for the simultaneous determination of these two elements by Different ial pulse anodic stripping voltammetry (DPASV) using Graphite mercury film electrode(GMFE) as a working electrode. The results showed that the optimum analytical conditions were when using Sodium acetate - acetic acid (0.05M) electrolyte, where pH= 4.6, and a concentration (25mg/l) of Hg2+, CCd:CPb ratio up to 1:10 and conversely, and the optimum technical conditions were when applying scanning field from -1200 to -100mV, accumulation potential Eacc= -1200mV, accumulation time tacc= 120sec, speed rate υ= 120mV/sec, and amplitude pulse ΔE= 50mV. The previous conditions gave ideal voltammetric curves, Ip(Cd)= 6.134µA, Ip(Pb)= 4.966µA, Ep(Cd) = -647 mV, Ep(Pb)= -473 mV. The previous conditions were applied on a standard sample and the limit of detection was (Cd) 0.100µg/l, (Pb) 1.000µg/l, retrieval coefficient R%(Cd)= 100.5%, R%(Pb)= 97.2%, standard deviation SD(Cd)= 0.020mg/l, SD(Pb)= 0.021mg/l; Therefore, that shows the accuracy and precision of the method. The validity of the method under its new conditions was examined on a number of environmental samples and showed success and high efficiency.
This research study the effect of the most important conditions on the voltammetric curves of lead and copper to reach the optimal conditions for the simultaneous determination of these elements by Differential pulse anodic stripping voltammetry (DPA SV) using a hanging mercury drop electrode (HMDE) as a working electrode. The results showed that the optimal conditions for the simultaneous determination of lead and copper by using nitric acids electrolyte 3M,were when applying scanning field from -700 mV to +150 mV, accumulation potential -800 mV, the time of the accumulation 80 sec, speed rate 40 mV/sec, and the amplitude pulse 70mV, where the peak currents were IP (Pb) = 274.2 nA, IP (Cu) = 630.5 nA, at peak potentials EP (Pb) = -380 mV, EP (Cu) = +40 mV, by applying the previous conditions, the limits of detection reached 1.05μg/l for lead 2.45 μg/l for copper. The retrieval coefficient calculated to make sure accuracy of the method and it reached 103.90% and copper 101.70% and to indicate the precision of the way by the standard deviation was the value of the standard deviation for lead 0.027 mg/l, and copper 0.013 mg/l. the method applied under its own conditions by examined on some of environmental and samples and showed success and high efficiency
This research includes a set of mathematical models for simulating the financial activities. Worked models are determined to approve the form of inflows to the bank and outflows. We tried to study different types of banks, and performed some condi tions to make sure that the bank is working in stabilized situation. Furthermore, we identified the factors affecting the achievement of stability. These models allow more flexibility in the discussion and analysis of banking operations, helping to discern periods approaching the crisis and draw attention to the overall status of the bank. Analyzing these models gives additional time to control withdrawal and take the necessary decision at the time.
The study investigated the possibility of removing heavy metal ions (Cd, Pb) from aqueous solutions using adsorption method on the citrus peel (orange), which is a solid waste available in abundance especially in the Syrian coast as well as easy to use at low cost. The optimal conditions for the simultaneous adsorption of the ions (Cd 2+, Pb 2+) on the surface of orange peel (dry, soft) were determined.The concetration of ions was determined using (DPASV) method Which is characterized by Sensitivity and high accurawcy. The results showed that the optimum adsorption conditions were at pH = 5 , equleibrium time = 60 min, and the initial concentration is ( C0 = 50-200) ppm,The application of the Langmuir and Frienlish models showed that Frienlish model is best fited for expressing the adsorption of Pb ions on the surface of dry and soft orange peel and for expressing the adsorption of Cd ions on the surface of soft orange peel , Langmuir model is best fited for expressing the adsorption of Cd ions on the surface of dry orange peel. The method applied its selected terms to realistic samples of processed and industrial waste water, which showed a unique response as a purification method for the water media.
This research aims to study the effect of certain analytical conditions to determine the arsenic in aqueous media using a Potentiometric, and then choose and adopt the optimum conditions for this determinism. We studied the effect of each of the (PH value, type, concentration puffer, effect of crippling electrolytes) to determine the arsenic in aqueous media and calibration using a standard solution of iodine. We also worked on raising the sensitivity of the method detection limit access to the ppm. It should be noted that technical conditions must be tuned to determine the actual value of the end point calibration and data processing of standard solution (initial velocity and deceleration near the end point calibration). The study showed that the PH value appropriate for calibration of arsenic with iodine (8-9), also found that the response process of arsenic on the electrode platinum has been excellent when using Na2SO4 as puffer with concentration of 0.1 M, which has been successfully used to quantify arsenic As+3 up to detect up to 2 × 10-6M. As it turns out during the study, it was not possible to determine the arsenic presence of copper ions in the solution, while the presence of lead and sulfate ions and chloride was not affective.
comments
Fetching comments Fetching comments
Sign in to be able to follow your search criteria
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا