This study aims to compare the results of two methods ,used to determinate arsenic in mixed and aqueous media: proposed potintiometrc titration and referenced atomic absorption and then applied the proposed method to some environmental samples. In this paper, Arsenic)III( has been titrated with iodine in aqueous and mixed media using the direct method and platinum electrode after choosing optimal technical and analytical conditions. The atomic absorption, which is often used to determine the arsenic in many applications, has been chosen as comparison guide, where the reaction take place between sodium borate (NaBH4) and arsenic Acid H3AsO3 to produce the effective compound AsH3 used to determine arsenic by this instrument . Different statistical treatments were used to evaluate the result of the determination of arsenic in desired media. The result of this investigation suggest that , it’s highly recommend to use the proposed method for its high efficiency, ease, simplicity and low cost comparing with atomic absorption technique that requires expensive equipment
This research study the effect of the proportion of the media (water - alcohol ) to determine where the arsenic used alcohol ( methanol _ ethanol _ propanol ) Using a Potentiometric method. It conducted the calibration process for the specific size o f the solution studied a specific size of the standard solution of iodine Using a Potentiometric method , after the application of analytical conditions and technical optimal to determine arsenic , and then we studied the effect of mixing ratio on the detection limit for arsenic in mixed media (water _ Alcohol ) . The study showed that the value of the detection limit of arsenic vary with the type of alcohol used and accounted for in the reaction medium , it reached to (1× 10-7 M) in media (75:25 water _ methanol ) , but when you use a media ( 75:25 water _ ethanol ) arrived to the limit of detection (1×10-4 M ), As for propanol arrived to the limit of detection (1×10-3 M). where the value reached detection limit of arsenic to (1× 10-5 M) in media ( 50:50 water _ methanol ) , but when you use a media ( 50:50 water _ ethanol ) arrived to the limit of detection (1×10-3 M ), As for propanol arrived to the limit of detection (1×10-2 M). The study showed that the use of the ratio ( 75:25 water _ alcohol ) gave a higher value limit of detection and therefore better results . Was calculated as the standard deviation and standard deviation percentile confidence limit in addition to the feedback that indicates the efficiency of the method of determining the concentration of arsenic detection limit for each medium.
This research aims to study the effect of certain analytical conditions to determine the arsenic in in mixed media (water _ alcohol ) where the user either alcohol ( methanol, ethanol , propanol using a Potentiometric, and then selected as conditi ons optimal certified for this determine. The effect of each of the (PH value, type, concentration electrolyte, effect of crippling electrolytes) to determine the arsenic in mixed media ( 50:50 water _ alcohol ) and calibration using a standard solution of iodine.In addition to that, there are technical conditions must be tuned to determine the actual value of the end point calibration and data processing of standard solution (initial velocity and deceleration near the end point calibration). The study showed that the PH value appropriate for calibration of arsenic with iodine (pH=8), also found that the response process of arsenic on the electrode platinum has been excellent when using NaHCO3 as electrolyte with concentration of 1 M, which has been successfully used to quantify arsenic As+3, where the value reached detection limit of arsenic to (1×10-5M) in media (50:50water _ methanol ) , but when you use a media ( 50:50 water _ ethanol ) arrived to the limit of detection (1×10-3 M ), As for propanol arrived to the limit of detection (1×10-2 M). Was calculated as the standard deviation and standard deviation percentile confidence limit in addition to the feedback that indicates the efficiency of the method of determining the concentration of arsenic and detection limit for each medium.
This research aims to study the effect of certain analytical conditions to determine the arsenic in aqueous media using a Potentiometric, and then choose and adopt the optimum conditions for this determinism. We studied the effect of each of the (PH value, type, concentration puffer, effect of crippling electrolytes) to determine the arsenic in aqueous media and calibration using a standard solution of iodine. We also worked on raising the sensitivity of the method detection limit access to the ppm. It should be noted that technical conditions must be tuned to determine the actual value of the end point calibration and data processing of standard solution (initial velocity and deceleration near the end point calibration). The study showed that the PH value appropriate for calibration of arsenic with iodine (8-9), also found that the response process of arsenic on the electrode platinum has been excellent when using Na2SO4 as puffer with concentration of 0.1 M, which has been successfully used to quantify arsenic As+3 up to detect up to 2 × 10-6M. As it turns out during the study, it was not possible to determine the arsenic presence of copper ions in the solution, while the presence of lead and sulfate ions and chloride was not affective.
The research was conducted in order to investigate the metal contaminants (lead Pb،cadmium Cd ، arsenic As), which moves from irrigation water to many types of vegetables which irrigated from it,and compared the extent of pollution by irrigation source (treatment sewage، wells water), and by vegetable type (Vegetables, fruit plants, tuberous), and by the irrigation method used (surface irrigation ، modern irrigation).