Do you want to publish a course? Click here

An analysis spectral study to ditermine the copper bilateral in some Syrian rocks by using the Alizarin Red S

دراسة تحليلية طيفية لتحديد نزر عنصر النحاس في بعض الصخور السورية باستخدام الأليزارين الأحمرAlizarin Red S

1807   0   51   0 ( 0 )
 Publication date 2015
and research's language is العربية
 Created by Shamra Editor




Ask ChatGPT about the research

In this research the development of the conditions of the determine copper duo by spectrophotometric method that based on the formation of a complex with Alizarin Red S was accamplished with the presence of fallow acid when the wavelength(220 nm), that by studying the effect of PH and the impact if the interference caused by the presence of some metal ions (nickel ions, chromiun ions, 2 inc ions, calciom ions, and triple iron ions) which make it difficult for the progress of determine copper by Alizarin Red S. the best PH value for this process is (pH = 9.5) and the relationship of Lambert Bear realized within the range 0.2 – 125 mg/ml the detection limit was 0.OO1µg/ml.


Artificial intelligence review:
Research summary
تتناول هذه الدراسة تحليل طيفي لتحديد نزر عنصر النحاس في بعض الصخور السورية باستخدام الكاشف العضوي الأليزارين الأحمر (Alizarin Red S). تم تحسين شروط التحليل الطيفي الضوئي لتحديد النحاس الثنائي من خلال تشكيل معقد مع الأليزارين الأحمر بوجود حمض البور عند طول موجي 220 نانومتر. تم دراسة تأثير درجة الحموضة (pH) وتأثير التداخلات الناتجة عن وجود بعض الأيونات المعدنية مثل النيكل والكروم والزنك والكالسيوم وأيونات الحديد الثلاثي التي تعيق عملية تحديد النحاس. أظهرت النتائج أن أفضل قيمة pH لتحديد النحاس هي 9.5 وأن مجال التركيز الذي تتحقق عنده العلاقة الخطية حسب قانون بيير-لامبرت هو 0.2 - 125 ميكروغرام/مل، مع حد كشف قدره 0.001 ميكروغرام/مل. تم تطبيق هذه الطريقة على عينات صخرية سورية لتحديد محتوى النحاس فيها، وأظهرت النتائج أن محتوى النحاس في الصخور الساحلية السورية لم يتجاوز 0.235 غرام/كغ. تم استخدام أجهزة تحليلية متعددة مثل مقياس طيفي ضوئي تقائي الحزمة يعمل في المجال المرئي وفوق البنفسجي، وميزان تحليلي، وجهاز قياس حموضة الوسط، وماصات حجمية ميكروية، وأدوات زجاجية مخبرية مختلفة. تم التوصل إلى أن بعض العناصر الكيميائية تشكل تداخلات مع الكاشف العضوي وتؤثر على نتائج تحديد النحاس، حيث كان الحديد هو العنصر الأكثر تداخلاً مع النحاس الثنائي، بينما كان الزنك هو الأقل تداخلاً.
Critical review
دراسة نقدية: تعتبر هذه الدراسة مهمة في مجال التحليل الكيميائي الطيفي لتحديد نزر العناصر المعدنية في الصخور، وقد أظهرت نتائج دقيقة ومفصلة حول تأثير العوامل المختلفة على تحديد النحاس. ومع ذلك، يمكن توجيه بعض النقد البناء لتحسين الدراسة. أولاً، كان من الممكن توسيع نطاق الدراسة لتشمل عينات صخرية من مناطق جغرافية مختلفة في سوريا للحصول على نتائج أكثر شمولية. ثانياً، لم يتم التطرق بشكل كافٍ إلى تأثير العوامل البيئية الأخرى مثل درجة الحرارة والرطوبة على نتائج التحليل. ثالثاً، كان من الممكن استخدام تقنيات تحليلية إضافية مثل مطيافية الامتصاص الذري لتعزيز دقة النتائج. وأخيراً، كان من المفيد تقديم توصيات عملية لتطبيق النتائج في مجالات الصناعة والزراعة بشكل أكثر تفصيلاً.
Questions related to the research
  1. ما هي أفضل قيمة pH لتحديد النحاس باستخدام الأليزارين الأحمر؟

    أفضل قيمة pH لتحديد النحاس باستخدام الأليزارين الأحمر هي 9.5.

  2. ما هو حد الكشف عن النحاس باستخدام هذه الطريقة؟

    حد الكشف عن النحاس باستخدام هذه الطريقة هو 0.001 ميكروغرام/مل.

  3. ما هي العناصر التي تعيق تحديد النحاس باستخدام الأليزارين الأحمر؟

    العناصر التي تعيق تحديد النحاس باستخدام الأليزارين الأحمر تشمل النيكل، الكروم، الزنك، الكالسيوم، وأيونات الحديد الثلاثي.

  4. ما هو محتوى النحاس في الصخور الساحلية السورية حسب الدراسة؟

    محتوى النحاس في الصخور الساحلية السورية حسب الدراسة لم يتجاوز 0.235 غرام/كغ.


References used
WEAST, R.C. Handbook of chemistry and physics. Boca Raton, 61st ed. FL: CRC Press,1980 B13, B97-BlOO
TUDDENHAM, W.M. DOUGALL, P.A. Copper. In: Kirk Othmer encyclopedia of chemical technology, Vol. 6, 3rd ed. New York, NY: John Wiley & Sons, 1978,819-869
COHEN, J.M.; KAMPHAKE, L.J.; HARRIS, E.K. et al. Task threshold concentrations of metals in drinking water. J Am Waterworks Assoc 52,1960,660-670
rate research

Read More

In this research improve the conditions determining zinc(II) using the method of optical spectroscopy based on the formation of a complex with BPT when the wavelength (430nm) and through the study of the impact of degrees pH the middle, and the eff ect of the interference caused by the presence of some of the nickel ions, iron(II) , calcium, copper, chromium, and manganese that hinder the process of identifying zinc-mediated this reagent .
This paper discuss the Laser induced breakdown spectroscopy (LIBS) by using Nd:YAG which is a high energy pulsed Laser . The laser radiation is focused on solid targets which are samples of red Copper (99.5%). Most important Plasma parameters which are electron temperature and density was measured.
The changes in coefficient of distribution of lead and cupper has been studied in system with two phases, liquid water contaminated with lead and copper-solid (natural Phosphate of Syria) correlation of the following factors: Time of mixing phases, size of the developed steel ,change the values of PH ,concentration of elemental lead and concentration of element capper ,the concentration of calcium as a competitor to the occupation of sites available on the solid phase, the ratio V\m presents the water phase size on the mass of phase ,the Percentage removal of lead from aqueous samples prepared in the laboratory91,57-99,95% were the best conditions for a vast proportion removed can be summarized as follows: PH=[6,63-10,11], Time of mixing phases =60 minutes and V/m=1000. The Percentage removal of copper from aqueous samples prepared in the laboratory 95,27 -99,96 % were the best conditions for a vast proportion removed can be summarized as follows: PH= [7,89-11,01] , Time of mixing phases =60 minutes and V/m=1000. Ideal conditions have been applied that were obtained according to laboratory tests on water samples from industrial input to Banias refinery and water samples from industrial drainage to Syrian company for oil transport after Removal for lead was( 100%,99 %). Removal for copper was( 100%,98 %) .
The objective of this study is to study some of the optimal analytical conditions for the determination of the Cu2+ ion using potentiometric titration method using the platinum electrode as a working electrode and the AgCL/Ag as a Reference electro de. In this study, the technical conditions were studied (working Electrode type, Reference Electrode type, Direction of titration, delay time, Proportional band, Speed of stirring) and the analytical conditions (pH value, time factor, quantity of solid KI added, electrolyte type and its concentration, detection limit) were studied using oxidation - reduction reactions as the method of iodide titration which applied successfully electrochemical for determine the Cu2+ ion.