An analytical chromatographic method for determination of total benzalkonium chloride in eye drops preparations samples containing gentamicin sulphate, tobramicin and viscous eye drops samples containing fusidic acid has been developed.


Artificial intelligence review:
Research summary
تقدم هذه الدراسة طريقة تحليلية كروماتوغرافية لتحديد كلوريد البنزألكونيوم في مجموعة من القطرات العينية التي تحتوي على الجنتاميسين سلفات والتوبراميسين والقطرات العينية اللزجة التي تحتوي على الفوسيديك أسيد. استخدمت الطريقة عمود كروماتوغرافي من نوع KNAUER CN وطور متحرك مكون من محلول موقي خلاتي وأسيتونتريل بنسبة حجمية (70:30) مع معدل تدفق 1.3 مل/دقيقة وكاشف طيفي عند طول موجة 215 نانومتر. أظهرت الطريقة خطية جيدة في مجال التركيز من 0.008 ملغ/مل إلى 0.028 ملغ/مل مع حد كشف أصغري 0.0025 ملغ/مل. كانت قيم الاسترجاعية تتراوح بين 99.56% و99.77%. أثبتت الاختبارات التحليلية صحة ودقة وصلاحية الطريقة، وتم تطبيقها بنجاح على عينات محلية وأجنبية دون الحاجة لمعالجة مسبقة لمكونات المستحضر الكيميائي.
Critical review
دراسة نقدية: تعتبر هذه الدراسة مهمة في مجال تحليل المستحضرات الدوائية العينية، حيث تقدم طريقة تحليلية دقيقة وسريعة لتحديد كلوريد البنزألكونيوم. ومع ذلك، يمكن أن تكون هناك بعض النقاط التي تحتاج إلى تحسين. على سبيل المثال، يمكن توسيع نطاق الدراسة ليشمل المزيد من المستحضرات الدوائية المختلفة لضمان تعميم النتائج. كما يمكن تحسين الشرح التفصيلي لبعض الخطوات التجريبية لتسهيل إعادة تنفيذها من قبل باحثين آخرين. بالإضافة إلى ذلك، يمكن أن تكون هناك حاجة لمزيد من الدراسات المقارنة مع طرق تحليلية أخرى لتأكيد تفوق هذه الطريقة.
Questions related to the research
  1. ما هي المواد الفعالة التي تم تحليلها في هذه الدراسة؟

    تم تحليل كلوريد البنزألكونيوم في القطرات العينية التي تحتوي على الجنتاميسين سلفات والتوبراميسين والفوسيديك أسيد.

  2. ما هو الطور المتحرك المستخدم في الطريقة التحليلية؟

    الطور المتحرك المستخدم هو محلول موقي خلاتي وأسيتونتريل بنسبة حجمية (70:30).

  3. ما هو حد الكشف الأصغري للطريقة التحليلية؟

    حد الكشف الأصغري للطريقة التحليلية هو 0.0025 ملغ/مل.

  4. هل تتطلب الطريقة التحليلية معالجة مسبقة لمكونات المستحضر الكيميائي؟

    لا، الطريقة التحليلية لا تتطلب معالجة مسبقة لمكونات المستحضر الكيميائي.


References used
R. C. Rowe, P. J. Sheskey, M. E. Quinn; 2009. Handbook of Pharmaceutical Excipients, 6th. ed., Pharmaceutical Press, 917P. English
G. Santoni, A. Tonsini, P. Gratteri, P. Mura, S. Furlanetto, S. Pinzauti; 1993. Determination of atropine sulphate and benzalkonium chloride in eye drops by HPLC, International Journal of Pharmaceutics, Volume 93, Issues 1–3, PP. 239-243
M. Gaber, M. Hazem Abu Shawish, M. Abdalla Khedr, I. Khalid Abed- Almonem; 2012. Determination of benzalkonium chloride preservative in pharmaceutical formulation of eye and ear drops using new potentiometric sensors, Materials Science and Engineering: C, Volume 32, Issue 8, PP. 2299-2305
rate research

Read More

spectrophotometric and chromatographic methods was used for determination of five water-soluble vitamins, including : Thiamine HCl (B1), Ascorbic acid (VC), Niacinamide (PP), Cyanocobalamin (B12), Riboflavin (B2) in this research. The conditions of chromatographic separation were reached to the vitamins with good resolution.
The purpose of this article is how to use HPLC technique for quantitive analysis of cholesterol in some foods. The best conditions are studied for this analysis including composition of mobile phase, temperature, flow rate, the wavelength of detec tor UV-VIS, and acidity of mobile phase. The column used for cholesterol determination by this method was: C18(5μm,250x4.6mm) with injection volume of 20μL. Methanol 100% was used as mobile phase.
Ninety-nine randomized samples of milk and white cheeses were collected from five districts in Damascus city during 2012-2013 to determinef Aflatoxin M1 using High Performance Liquid Chromatography (HPLC). The procedure for determination of Aflato xin M1 was changed according to local circumnutates which gave sensitive and accurate results during 5.9 minute with r= 0.99. The average recovery was 83.88% for milk and 102.15% for cheeses samples, respectively.
A simple and accurate method was developed for the analysis of carbinoxamine maleate, dextromethorphan hydrobromide and pseudoephedrine hydrochloride content in pure form and pharmaceutical preparations using HPLC. Analysis was conducted on a sili ca column (6 μm) with mobile phase consisting of ethanol – ammonium acetate (0.05 M) in rate [85:15] respectively, and at detection wavelength of 276 nmand flow rate 1ml/ min. Results were linear (correlation coefficient R > 0.9996) in the range of the studied concentrations for the active materials. The relative standard deviations (n=6) of intra and interday assay were 0.931%, 1.527% for carbinoxamine maleate and 0.717%, 1.058 % for dextromethorphan hydrobromide and 0.309%, 0.891% for pseudoephedrine hydrochloride, respectively. This method, proved to be easy, precise and economical, is useful for quality control of pharmaceutical drugs industrial samples.
comments
Fetching comments Fetching comments
Sign in to be able to follow your search criteria
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا