Measuring the radioactivityof(137Cs) and (40K) isotopes of milk samples from different sourcesin the Lattakia’s Regions

قياس النشاط الإشعاعي الناتج عن نظيري السيزيوم (137Cs) و البوتاسيوم (40K) لعينات حليب من مصادر مختلفة في محافظة اللاذقية

1797   0   69   0 ( 0 )
 Publication date 2013
and research's language is العربية
 Created by Shamra Editor




Ask ChatGPT about the research

In this research, we have measured the radioactivity resulting from the Cesium-137 and Potassium-40 isotopes, in milk samples (from different sources) in Lattakia’s regions. It has been found that all samples were not contaminated by Cesium-137, but it was recorded that all samples containing radioactivity resulting from the Potasium-40 isotope with a magnitude range between , and average value . As compared with other world results, there was a good agreement between them, taking into account the errors in measurements.


Artificial intelligence review:
Research summary
في هذا البحث، تم قياس النشاط الإشعاعي الناتج عن نظيري السيزيوم-137 والبوتاسيوم-40 في عينات حليب من مصادر مختلفة في محافظة اللاذقية. أظهرت النتائج أن جميع العينات خالية من النشاط الإشعاعي لنظير السيزيوم-137، بينما تحتوي على نشاط إشعاعي لنظير البوتاسيوم-40 بقيم تتراوح بين 45 و81 بيكريل/لتر، مع قيمة وسطى تبلغ 60 ± 9 بيكريل/لتر. تم مقارنة هذه النتائج مع نتائج عالمية أخرى، حيث أظهرت توافقًا جيدًا معها، مع مراعاة الأخطاء المرتكبة في القياسات. يشير البحث إلى أهمية مراقبة النشاط الإشعاعي في المواد الغذائية، خاصة بعد الحوادث النووية التي تسببت في تلوث البيئة بالعناصر المشعة.
Critical review
دراسة نقدية: يعتبر هذا البحث خطوة مهمة في مجال مراقبة النشاط الإشعاعي في المواد الغذائية، ولكن هناك بعض النقاط التي يمكن تحسينها. أولاً، كان من الأفضل توسيع نطاق الدراسة لتشمل مناطق أخرى في سوريا للحصول على صورة أشمل. ثانياً، لم يتم التطرق إلى تأثيرات النشاط الإشعاعي على الصحة بشكل مفصل، وهو جانب مهم يجب أخذه بعين الاعتبار. ثالثاً، كان من الممكن استخدام تقنيات أكثر حداثة ودقة في القياس لتحسين موثوقية النتائج. وأخيراً، يجب أن تكون هناك توصيات واضحة حول كيفية التعامل مع النتائج وتطبيقها في السياسات العامة.
Questions related to the research
  1. ما هي النظائر المشعة التي تم قياسها في هذا البحث؟

    تم قياس النشاط الإشعاعي لنظيري السيزيوم-137 والبوتاسيوم-40.

  2. ما هي النتيجة الرئيسية المتعلقة بنظير السيزيوم-137 في عينات الحليب؟

    جميع العينات كانت خالية من النشاط الإشعاعي لنظير السيزيوم-137.

  3. ما هو النطاق الذي تراوحت فيه قيم النشاط الإشعاعي لنظير البوتاسيوم-40 في العينات؟

    تراوحت قيم النشاط الإشعاعي لنظير البوتاسيوم-40 بين 45 و81 بيكريل/لتر.

  4. كيف تم مقارنة نتائج البحث مع النتائج العالمية؟

    تمت مقارنة النتائج مع نتائج عالمية أخرى وأظهرت توافقًا جيدًا معها، مع مراعاة الأخطاء المرتكبة في القياسات.


References used
Collette Chassard-Bouchaud, Environnement et radioactivité, Que sais-je ? Presses universitaires de France, 1993, See chapter IX, 93-105
International Nuclear Event Scale (INES),Rating on the Events in Fukushima Dai-ichi Nuclear Power Station, Nuclear and Industrial Safety Agency, 12 April 2011
Report of the Expert Consultation on Recommended Limits for Radionuclide Contamination of Food, Rome, 1-5 December 1986. ESN/MISC/87/1, Rome, FAO
rate research

Read More

In this research, measurement of radioactivity of bismuth-212 in the soil of the village of the Ien Lailonin- Alhafah area- Latakia city using gamma spectrometry to make sure the radioactive content to soil, and was measuring the radioactivity of b ismuth-212 using the alpha spectroscopy, after digestion 10g of soil using nitric acid and sulfuric acid concentrated, and then spontaneaous deposition into high purity a silver disc. the results show that: the radioactivity of bismuth-212 (1,48Bq) using gamma spectrometry and (2,05Bq)using the alpha spectroscopy It is within the range allowed international border ,taking into account the errors in measurements.
In this work, we have used the basic techniques for measuring gamma rays. It is based on the use of a sodium iodide (NaI) detector withthallium activated (Tl). We have obtained:  The detector calibration NaI(Tl) and the resolution of the spectrom eter.  Measuring and determining the activity of a source can be doneby using the relative, and the absolute method. The results obtained show bythe Comparison between the experimental and the theoretical(of the sources activities)a good agreement, and the best values obtained by the absolute method.
The bacterial case of groundwater samples from Homs Governorate was studied to determine the bacterial load, Twenty-eight groundwater samples were collected from various areas (including areas of the western, northern and eastern governorates of the governorate) between March and July 2017. Where they were collected in sterile glass containers after opening and running the water for 5 minutes to avoid any external contamination.
This research studied the impact of planting location and cooking time periods of (5, 10, 15, 20 and 40 minutes) on the antioxidant effect, and on the total Phenols and Flavonoids contents using five different samples of Syrian onions. The results showed that the total Phenols, total Flavonoids and antioxidant activity contents were between (279-583)mg/100g dry wt, (80-180)mg/100g dry wt, and (60-75%) respectively. In addition, boiling for different periods resulted in increased total Phenols from (383 to789)mg/100g dry wt and in total Flavonoids from (124 to 205)mg/100g dry wt as well as an increase of (77% to 88%) of antioxidant activity as measured using the DPPH method.
In this experimental work, the instruments used (detector, calibrating sources) has been calibrating, the calibration line of the detector deduced and it has been finding that the equation of calibration line takes the form: The resolution power R has been studying as function of the distance between the activity source and detector; the results obtained show that R decrease by increase the energy of the lines spectrum, this mean that the detector resolution power become bigger. It has been measured the LC، LD and MDA using two different methods of background radiation value, trapezium method and classical method, for two different distances between radioactivity source and detector: (9,3cm) and (10cm). The results show: 1- There is similar comportment of the LC، LD and MDA in function energy and the distance between radioactivity source and detector. 2- The trapezium method gives better results from the classical method to the radiation background, and this leads to lesser MDA value, this means that the sensibility is bigger to measure this quantity. 3- The relative error using MDA is (5%) for large values, and (10%) for small values