Analytical and experimental study of the mechanisms of computing and measuring the radioactivity of the radioactive sources

دراسة تحليلية و تجريبية لآليات حساب و قياس النشاط الإشعاعي للمنابع المُشعة

1723   0   93   0 ( 0 )
 Publication date 2014
  fields Physics
and research's language is العربية
 Created by Shamra Editor




Ask ChatGPT about the research

In this work, we have used the basic techniques for measuring gamma rays. It is based on the use of a sodium iodide (NaI) detector withthallium activated (Tl). We have obtained:  The detector calibration NaI(Tl) and the resolution of the spectrometer.  Measuring and determining the activity of a source can be doneby using the relative, and the absolute method. The results obtained show bythe Comparison between the experimental and the theoretical(of the sources activities)a good agreement, and the best values obtained by the absolute method.


Artificial intelligence review:
Research summary
تتناول هذه الدراسة التحليلية والتجريبية آليات حساب وقياس النشاط الإشعاعي للمنابع المشعة باستخدام تقنيات قياس أشعة غاما. تم استخدام كاشف من يوديد الصوديوم (NaI) المشاب بالثاليوم (Tl) لتحقيق هذا الهدف. تتضمن الدراسة معايرة الكاشف وتحديد قدرته على الفصل الطيفي. تم قياس النشاط الإشعاعي للمنابع المشعة باستخدام طريقتين: الطريقة النسبية والطريقة المطلقة. أظهرت النتائج تطابقاً جيداً بين القيم التجريبية والنظرية للنشاط الإشعاعي، وكانت أفضل القيم المحصلة باستخدام الطريقة المطلقة. تتضمن الدراسة وصفاً للأجهزة المستخدمة، حساب النشاط الإشعاعي نظرياً وتجريبياً، ومناقشة النتائج المستخلصة. الهدف الرئيسي من البحث هو مقارنة الطرق المختلفة لقياس النشاط الإشعاعي وتحديد الطريقة الأكثر دقة وفعالية.
Critical review
دراسة نقدية: تعتبر هذه الدراسة شاملة ومفصلة في مجال قياس النشاط الإشعاعي، وتقدم معلومات قيمة حول استخدام كاشف يوديد الصوديوم (NaI) المشاب بالثاليوم (Tl). ومع ذلك، يمكن توجيه بعض النقد البناء لتحسين الدراسة. أولاً، كان من الممكن تضمين مزيد من التفاصيل حول العوامل البيئية التي قد تؤثر على القياسات، مثل درجة الحرارة والرطوبة. ثانياً، قد يكون من المفيد إجراء مقارنة مع أنواع أخرى من الكواشف لتقديم صورة أكثر شمولية عن كفاءة الكاشف المستخدم. أخيراً، كان من الممكن توسيع نطاق الدراسة لتشمل تطبيقات عملية في مجالات مختلفة مثل الطب النووي والصناعة، مما يزيد من فائدة البحث العملية.
Questions related to the research
  1. ما هي الأجهزة المستخدمة في قياس النشاط الإشعاعي في هذه الدراسة؟

    الأجهزة المستخدمة تشمل كاشف وميضي من يوديد الصوديوم (NaI) المشاب بالثاليوم (Tl)، محلل متعدد الأقنية، وحاسوب مجهز ببرنامج CASSY لمعالجة القياسات.

  2. ما هي الطريقة التي أظهرت أفضل نتائج في قياس النشاط الإشعاعي؟

    الطريقة المطلقة أظهرت أفضل نتائج في قياس النشاط الإشعاعي مقارنة بالطريقة النسبية.

  3. ما هو الهدف الرئيسي من هذه الدراسة؟

    الهدف الرئيسي هو حساب وقياس النشاط الإشعاعي للمنابع المشعة باستخدام الطرائق المعروفة والمستخدمة في هذا المجال، ومن ثم مقارنة هذه الطرائق ببعضها البعض.

  4. ما هي العوامل التي تؤثر على كفاءة الكاشف المستخدم في الدراسة؟

    العوامل التي تؤثر على كفاءة الكاشف تشمل امتصاص الأشعة وتشتتها ضمن المنبع نفسه أو بوساطة المادة بين المنبع والكاشف، الكفاءة الهندسية للكاشف، والكفاءة الذاتية للكاشف.


References used
Atomic and Nuclear Physics, Radioactivity, Detection of Radioactivity, Printed in the Federal Republic of Germany by Leybold Didactic GmbH, 2007, experiment p6.5.6.1, 1-4
J. Jabbour, H. Jbeli and J. Mulhem, Study of Experimental Characteristics of a NaI(Tl) Detector For Investigation in Radioactivity Measurements Of a Weakly radioactive samples. Accepted for publication in Tishreen University Journal, 2011
J. Jabbour, J. Mulhem and S. Yassin, Experimental Study of the Conservation Law in Compton Effect. Accepted for publication in TishreenUniversity Journal, 2012
rate research

Read More

In this experimental work, the instruments used (detector, calibrating sources) has been calibrating, the calibration line of the detector deduced and it has been finding that the equation of calibration line takes the form: The resolution power R has been studying as function of the distance between the activity source and detector; the results obtained show that R decrease by increase the energy of the lines spectrum, this mean that the detector resolution power become bigger. It has been measured the LC، LD and MDA using two different methods of background radiation value, trapezium method and classical method, for two different distances between radioactivity source and detector: (9,3cm) and (10cm). The results show: 1- There is similar comportment of the LC، LD and MDA in function energy and the distance between radioactivity source and detector. 2- The trapezium method gives better results from the classical method to the radiation background, and this leads to lesser MDA value, this means that the sensibility is bigger to measure this quantity. 3- The relative error using MDA is (5%) for large values, and (10%) for small values
In this work, it has been recording the alpha particles emitted from an Amerecium-241 source, and scattered by a gold and Aluminum thin foils as a function of the scattering angle q (0o-30o), using a semiconductor detector and Rutherford scattering c hamber. It always has been measuring the differential cross section resulting from this scattering, and experimentally determining the atomic number of Gold and Aluminum. Comparison between experimental and theoretical results shows a good agreement.
In this research, measurement of radioactivity of bismuth-212 in the soil of the village of the Ien Lailonin- Alhafah area- Latakia city using gamma spectrometry to make sure the radioactive content to soil, and was measuring the radioactivity of b ismuth-212 using the alpha spectroscopy, after digestion 10g of soil using nitric acid and sulfuric acid concentrated, and then spontaneaous deposition into high purity a silver disc. the results show that: the radioactivity of bismuth-212 (1,48Bq) using gamma spectrometry and (2,05Bq)using the alpha spectroscopy It is within the range allowed international border ,taking into account the errors in measurements.
CdTe Thin films were deposited on glass substrates by thermal evaporation method. The geometric thickness was calculated using interferometric method based on reflectance curve recorded with the spectrophotometer. The XRD analysis and optical char acterizations of CdTe films with different optical thicknesses reveals that the structure of the films is polycrystalline with preferential orientation (111). The structure constant (a), crystallite size (D), dislocation density (δ) and strain (ε) were calculated, and it is observed that the crystallite size increases but micro-strain and dislocation density decreases with increases in thin film thickness. The overall absorbance has been increased with the film thickness and the direct band gap was obtained. It decreases with the increase in the thickness of the films.
In this research, we have measured the radioactivity resulting from the Cesium-137 and Potassium-40 isotopes, in milk samples (from different sources) in Lattakia’s regions. It has been found that all samples were not contaminated by Cesium-137, but it was recorded that all samples containing radioactivity resulting from the Potasium-40 isotope with a magnitude range between , and average value . As compared with other world results, there was a good agreement between them, taking into account the errors in measurements.

suggested questions