3D finite elements analysis study aims to conduct a biomechanical comparison between two cantilever’s lengths with two different degrees of tilting the implants.

References used
Misch CE. Contemporary Implant Dentistry. Implant Dent. 1999;8(1):90
Maló P, Rangert B3 Nobre M3 “All‐on‐Four” Immediate‐Function Concept with Brånemark System® Implants for Completely Edentulous Mandibles: A Retrospective Clinical Study. Clin Implant Dent Relat Res. 2003;5(s1):2-9
Agliardi E, Panigatti S, Clerico M, Villa C, Malo P. Immediate rehabilitation of the edentulous jaws with full fixed prostheses supported by four implants: interim results of a single cohort prospective study. Clin Oral Implants Res. 2010;21(5):459-65
rate research

Read More

the density of bone having an obvious effect on the osseointegration and the success of the dental implants. The aim of the present study is to evaluate the effect of different bone qualities on the values and distribution of stresses at the bone – impla
This study aims to investigate the effect of the alveolar ridge shape in the distribution of stress at the lower removable partial dentures supported by implants using a finite element method, with four models for a half mandible are designed with a free end saddle using an ANSYS program and Canine was abutment, where the remaining ridge is representing the four alveolar ridge shapes (horizontal and distal descending and concave and distal ascending), two removable partial dentures were designed for each model one supported by tooth and fibromucosa and another one supported by tooth and implant, it has been applied a load of 50 Newton on all models and has been studied stress equivalent for each model.
Preserving the bone surrounding the implant is one of the most important factors in the success and durability of this implant, and the change in the quantity and quality of the surrounding bone not only affects the bone fusion of it, but also causes a change in the shape of the soft tissues covering and thus affects the aesthetic and functional aspect of the treatment.