Do you want to publish a course? Click here

Study of Mutual Influence in Binary System Se(IV)-Cu(II) on Glassy Carbon Electrode Modified with Copper Selenide by Using the Voltammetric Method

دراسة التأثير المتبادل في الجملة الثنائية (Se(IV)-Cu(II على مسرى الغرافيت الزجاجي المعدّل بسيلينيد النحاس بالطريقة الفولط أمبيرومترية

935   0   103   0 ( 0 )
 Publication date 2014
and research's language is العربية
 Created by Shamra Editor




Ask ChatGPT about the research

The glassy carbon electrode has been used as working electrode, to study the electrochemical behavior of Se(IV), by using anodic stripping voltammetric method (ASV) in acidic media HCl. We found that The reason for the absence of analytical signals expressed on flow any electrodic process due to reduction mechanism of Se(IV) on glassy carbon electrode from Se4+to Se2- and formation H2Se.


Artificial intelligence review:
Research summary
تتناول هذه الدراسة السلوك الكهركيميائي للسيلينيوم الرباعي على مسرى الغرافيت الزجاجي باستخدام طريقة التعرية الآنودية الفولط أمبيرومترية (ASV) في الأوساط الحمضية القوية. لم تُسجل أي إشارات كاتودية أو آنودية عائدة للسيلينيوم، ويُعزى ذلك إلى إرجاع السيلينيوم من الحالة الرباعية إلى الثنائية وتشكيل الهدريد الغازي H2Se بدلاً من تراكم السيلينيوم العنصري على سطح المسرى. تم تعديل المسرى الغرافيتي الزجاجي كهركيميائياً بسيلينيد النحاس، ودرس السلوك الكهركيميائي للجملة (Se(IV)-Cu(II)) على المسرى المعدل، حيث تم تسجيل إشارات آنودية وكاتودية تعودان لأكسدة وإرجاع المركب المشترك Cu2Se المتراكم على سطح المسرى. تتعلق تيارات هذه الإشارات بتركيز كل من السيلينيوم الرباعي والنحاس الثنائي. تم تطوير طريقة تحليلية لتعيين السيلينيوم بوجود تركيز ثابت من النحاس، واختبرت الطريقة على عينات تجريبية وواقعية وكانت نتائجها منضبطة إحصائياً. قيمة %RSD كانت ضمن المجال %(0.207-0.2011).
Critical review
دراسة نقدية: الدراسة تقدم إسهاماً مهماً في مجال الكيمياء التحليلية من خلال تطوير طريقة جديدة لتعيين السيلينيوم باستخدام مسرى الغرافيت الزجاجي المعدل بسيلينيد النحاس. ومع ذلك، يمكن الإشارة إلى بعض النقاط التي قد تحتاج إلى تحسين. أولاً، لم تُوضح الدراسة بشكل كافٍ تأثير العوامل البيئية المختلفة على دقة النتائج، مثل درجة الحرارة والضغط. ثانياً، قد يكون من المفيد تقديم مقارنة مع طرق تحليلية أخرى لتعيين السيلينيوم لتوضيح مدى تفوق الطريقة المقترحة. وأخيراً، يمكن تعزيز الدراسة بإجراء تجارب إضافية على عينات من بيئات مختلفة لتأكيد فعالية الطريقة في ظروف متنوعة.
Questions related to the research
  1. ما هو السبب الرئيسي لعدم تسجيل إشارات كاتودية أو آنودية للسيلينيوم الرباعي على مسرى الغرافيت الزجاجي؟

    السبب الرئيسي هو إرجاع السيلينيوم من الحالة الرباعية إلى الثنائية وتشكيل الهدريد الغازي H2Se بدلاً من تراكم السيلينيوم العنصري على سطح المسرى.

  2. كيف تم تعديل المسرى الغرافيتي الزجاجي في الدراسة؟

    تم تعديل المسرى الغرافيتي الزجاجي كهركيميائياً بسيلينيد النحاس.

  3. ما هي العلاقة بين تيارات الإشارات وتركيز السيلينيوم الرباعي والنحاس الثنائي؟

    تيارات الإشارات تتعلق بتركيز كل من السيلينيوم الرباعي والنحاس الثنائي، حيث تم رسم العلاقات بين تيارات الإشارات بدلالة تركيز السيلينيوم الرباعي وكانت خطية طردية ضمن مجال التراكيز 1-14 µM.

  4. ما هي القيمة النسبية للانحراف المعياري النسبي (RSD) التي تم الحصول عليها في الدراسة؟

    قيمة %RSD كانت ضمن المجال %(0.207-0.2011).


References used
BRAININA Kh. Z., 1974 - Stripping Voltammetry in Chemical Analysis. New York, Toronto, Halsted Press, 222p
VYDRA F., ŠTULIK K., JULAKOVA E., 1978– Electrochemical Stripping Analysis, New York, Toronto, Halsted Press, 361p
BRAININA Kh. Z., NEIMAN E. Ya., 1982– Solid Phase Reactions in Electro-analytical Chemistry. Moscow, Khimiya Press, 264p
rate research

Read More

This research studying the effect of the most important analytical and technical conditions on the voltammetric curves of lead and cadmium in order to choose the optimal conditions for the simultaneous determination of these two elements by Different ial pulse anodic stripping voltammetry (DPASV) using Graphite mercury film electrode(GMFE) as a working electrode. The results showed that the optimum analytical conditions were when using Sodium acetate - acetic acid (0.05M) electrolyte, where pH= 4.6, and a concentration (25mg/l) of Hg2+, CCd:CPb ratio up to 1:10 and conversely, and the optimum technical conditions were when applying scanning field from -1200 to -100mV, accumulation potential Eacc= -1200mV, accumulation time tacc= 120sec, speed rate υ= 120mV/sec, and amplitude pulse ΔE= 50mV. The previous conditions gave ideal voltammetric curves, Ip(Cd)= 6.134µA, Ip(Pb)= 4.966µA, Ep(Cd) = -647 mV, Ep(Pb)= -473 mV. The previous conditions were applied on a standard sample and the limit of detection was (Cd) 0.100µg/l, (Pb) 1.000µg/l, retrieval coefficient R%(Cd)= 100.5%, R%(Pb)= 97.2%, standard deviation SD(Cd)= 0.020mg/l, SD(Pb)= 0.021mg/l; Therefore, that shows the accuracy and precision of the method. The validity of the method under its new conditions was examined on a number of environmental samples and showed success and high efficiency.
This research study the effect of the most important conditions on the voltammetric curves of lead and copper to reach the optimal conditions for the simultaneous determination of these elements by Differential pulse anodic stripping voltammetry (DPA SV) using a hanging mercury drop electrode (HMDE) as a working electrode. The results showed that the optimal conditions for the simultaneous determination of lead and copper by using nitric acids electrolyte 3M,were when applying scanning field from -700 mV to +150 mV, accumulation potential -800 mV, the time of the accumulation 80 sec, speed rate 40 mV/sec, and the amplitude pulse 70mV, where the peak currents were IP (Pb) = 274.2 nA, IP (Cu) = 630.5 nA, at peak potentials EP (Pb) = -380 mV, EP (Cu) = +40 mV, by applying the previous conditions, the limits of detection reached 1.05μg/l for lead 2.45 μg/l for copper. The retrieval coefficient calculated to make sure accuracy of the method and it reached 103.90% and copper 101.70% and to indicate the precision of the way by the standard deviation was the value of the standard deviation for lead 0.027 mg/l, and copper 0.013 mg/l. the method applied under its own conditions by examined on some of environmental and samples and showed success and high efficiency
A new carbon paste electrode (CPE) for Co2+ ion modified with complex of Cobalt(II) with 1-(2-pyridylazo)-2-naphthol (PAN) as electroactive 84aterial was prepared. The best performances were obtained by carbon paste electrode with the composition Graphit powder (47%), DOPH as plasticizer (47%) and Co-PAN as electroactive material (6%)
Ion selective electrode of Cu٢+ for determining of copper (II) in acid and Ammonia Solutions is presented. Optimal conditions and main characteristics of such electrode have been determined. The effect of anionic surfactants on the electrode has b een investigated. The use of protective film such as cellophane, cellulose acetate, Lavsan, or nitro cellulose could be possible in order to avoid the difficulties related to the work in surfactant presented in the solutions.
A sensitive, simple, selective spectrophotometric method has been developed for determination Cobalt (II) with 1-(2-pyridylazo)-2 naphthol (PAN). This method ralies on the formation of stable red colored complex at pH=4.1 which has an absorption maximum at 580nm.
comments
Fetching comments Fetching comments
Sign in to be able to follow your search criteria
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا