Do you want to publish a course? Click here

تصميم منظم أوكتاني الكتروني لإلغاء حادثة الطرق من خلال تطبيق المتحكمات الصغرية في دارة الاشتعال لسيارة حديثة

775   0   29   0 ( 0 )
 Publication date 2014
and research's language is العربية
 Created by Shamra Editor




Ask ChatGPT about the research

No English abstract

References used
الوفائي, حسام. تصميم الدارات الالكترونية باستخدام المتحكمات الصغرية، سورية 2013
علي، حسين. مشروع متحكم قابل للبرمجة باستخدام المنطق السلمي، 2010
حسن، علي. المتحكم الصغير, 2006
rate research

Read More

IDDQ testing techniques are used to detect the physical defects such gate oxide shorts,floating gates and bridging faults, and which happen for the presence of manufacturing faults during the manufacturing processes of CMOS integrated circuits, wh ich cannot be detected by classical logical testing.
This paper shows how to design and implement control circuit in the movement of pv board to reach to maximal possible output, by designing a system to integrate several methods of of control with each other. During this work, we will design through formation a unified system combine control by light sensors, and control via data base on the other hand. In addition to compare pv angle in both ways. The proposed circuit designed, conduct a simulation, and implementation a miniature model simulates reality, and discussed the result to to conflict the advantage and the goal of using the proposed system. All that by using micro controller (PIC).
This research presented the experimental study of improving flow conditions in pump-sump provided with an axial or mixed pump, and vertical suction pipe, to ensure reducing the minimum needed submergence of the sump. A physical model of rectangula r shaped pumpsump had been studied, with a scale 1\10 , according to Froude Model. Three modifications had been added, including: floating element, conical element, and the third one consists of both of them. The flow had been watched for vortices observation whether surface or subsurface. Piezometric pressures had been measured at eight points, distributed equally on the suction pipe perimeter near pump impeller, in addition to swirl degree measure near pump impeller too. The results showed that the floating element, set behind the suction pipe, is the most appropriate and most effective solution to reduce the submergence in pump-sump in way which the other hydraulic criterions, which control the flow stability towards the suction pipe in the sump, don't be affected negatively.
في هذه الورقة نشرح طریقة استخدام المعلومات الناتجة عن الخبرة و ذات التحدید اللغوي بدلاً من المعادلات الریاضية الدقيقة و غير المرنة عند التطبيق. كما نجري مقارنة بين المتحكم التقليدي (D.I.P) و متحكم آخر یعتمد على نظام المنطق الملتبس باستخدام برنامج محاكاة .
comments
Fetching comments Fetching comments
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا