Do you want to publish a course? Click here

The Impact Of Distribution Generation On Voltage Stability And Its Relation With The Type Of Generator(Synchronous-Induction) In Static And Dynamic State Of Electrical Network

تأثير التوليد الموزع على استقرار الجهد الكهربائي و علاقته بنوع المولد المستخدم (تزامني-تحريضي) في الحالة الساكنة و الديناميكية للشبكة الكهربائية

3224   1   85   0.0 ( 0 )
 Publication date 2018
and research's language is العربية
 Created by Shamra Editor




Ask ChatGPT about the research

Due to the large and rapid increase in the demand for electricity and the gradual decline of non-renewable sources of energy (fossil fuels, etc.), the performance of electrical systems has to be developed so the use of distributed generation and its connection with the main networks is one of these methods but this linkage causes some problems like changing in electrical voltage. In this research a radial electric distribution system was simulated and studied the effect of distributed generation on electrical voltage stability -in static and dynamic state-and its effect when the generator is synchronous or induction.


Artificial intelligence review:
Research summary
يتناول البحث تأثير التوليد الموزع على استقرار الجهد الكهربائي وعلاقته بنوع المولد المستخدم (تزامني أو تحريضي) في الحالة الساكنة والديناميكية للشبكة الكهربائية. نظراً للزيادة الكبيرة في الطلب على الطاقة الكهربائية والانحسار التدريجي لمصادر الطاقة غير المتجددة، أصبح من الضروري تحسين أداء المنظومات الكهربائية. يعتبر التوليد الموزع وربطه مع الشبكات الكهربائية الرئيسية أحد الأساليب المستخدمة لتحقيق ذلك، ولكنه يسبب بعض المشاكل مثل تغير الجهد الكهربائي. في هذا البحث، تم نمذجة نظام توزيع كهربائي شعاعي ودراسة تأثير الربط الموزع على استقرار الجهد الكهربائي في الحالتين الساكنة والديناميكية، مع الأخذ بعين الاعتبار نوع المولد المستخدم. تم اختبار ربط مولدات تحريضية وتزامنية على عقد مختلفة في الشبكة، وتمت مراقبة استقرار الجهد الكهربائي في الحالتين. أظهرت النتائج أن للمولدات التزامنية تأثير أكبر على استقرار الجهد بسبب قدرتها على حقن الاستطاعة الردية، بينما يكون تأثير المولدات التحريضية أقل وضوحاً. كما تبين أن موقع وصل المولدات الموزعة له تأثير أكبر على العقد المجاورة مقارنة بالعقد البعيدة. توصي الدراسة بضرورة دراسة موقع ونوع المولد الموزع قبل إضافته إلى الشبكة الكهربائية لتجنب تأثيرات سلبية على استقرار الجهد الكهربائي.
Critical review
دراسة نقدية: يعتبر البحث مهماً في مجال تحسين استقرار الجهد الكهربائي في الشبكات الكهربائية، خاصة في ظل التوجه نحو استخدام التوليد الموزع. ومع ذلك، يمكن توجيه بعض النقد البناء للبحث. أولاً، كان من الممكن توسيع نطاق الدراسة لتشمل أنواع أخرى من المولدات الموزعة مثل مولدات الطاقة الشمسية أو الرياح، والتي أصبحت شائعة في الوقت الحالي. ثانياً، لم يتناول البحث بالتفصيل تأثير التوليد الموزع على جوانب أخرى من الشبكة الكهربائية مثل الحماية الكهربائية والخسائر في الطاقة. ثالثاً، كان من الممكن تحسين البحث بإجراء تجارب ميدانية بالإضافة إلى النمذجة النظرية للحصول على نتائج أكثر دقة وواقعية. على الرغم من هذه النقاط، يظل البحث قيمة مضافة في مجال دراسة تأثير التوليد الموزع على استقرار الجهد الكهربائي.
Questions related to the research
  1. ما هو الهدف الرئيسي من البحث؟

    الهدف الرئيسي من البحث هو دراسة تأثير التوليد الموزع على استقرار الجهد الكهربائي في الشبكة الكهربائية، مع التركيز على نوع المولد المستخدم (تزامني أو تحريضي) في الحالتين الساكنة والديناميكية.

  2. ما هي النتائج الرئيسية التي توصل إليها البحث؟

    توصل البحث إلى أن للمولدات التزامنية تأثير أكبر على استقرار الجهد الكهربائي بسبب قدرتها على حقن الاستطاعة الردية، بينما يكون تأثير المولدات التحريضية أقل وضوحاً. كما تبين أن موقع وصل المولدات الموزعة له تأثير أكبر على العقد المجاورة مقارنة بالعقد البعيدة.

  3. ما هي التوصيات التي قدمها البحث؟

    يوصي البحث بضرورة دراسة موقع ونوع المولد الموزع قبل إضافته إلى الشبكة الكهربائية لتجنب تأثيرات سلبية على استقرار الجهد الكهربائي.

  4. ما هي الفروقات بين المولدات التزامنية والتحريضية من حيث تأثيرها على استقرار الجهد الكهربائي؟

    المولدات التزامنية لديها القدرة على حقن الاستطاعة الردية مما يجعل تأثيرها على استقرار الجهد الكهربائي أكبر، بينما المولدات التحريضية تستهلك استطاعة ردية فقط، مما يجعل تأثيرها على استقرار الجهد أقل وضوحاً.


References used
The electric power engineering Handbook-L L Grisby 2001
Distributed Generation: A Definition- Thomas Ackermann 2001
Stabitity of distribution networks with embedded generators and induction motors – J.V. Milanovic 2002
rate research

Read More

With the increased loading of Syrian power system, the problem of maintaining the voltages within the acceptable ranges has become a major concern in power system planning and operation. The purpose of this research is studying Impact of Connecti on Shunt Capacitors as facility to improve voltage and evaluate the voltage profile in the Syrian transmission network 230-400kV, determine weak bus bars of voltage, as well as the generation ,the consumption and losses of active and reactive power.
In this research the dynamic impact of the interconnection on the rotor angle Stability for Synchronous Generators in the Syrian Network were analyzed through the dynamic simulation of the power system and building of equations is linear and then use the program PSS / E (Power system simulation)to resolve and identify determinants of the system and determine critical fault clearing times of three-phase faults on the 400 KV addition to identifying the angular revolving generators and thus to verify the stability whether of its work independently within the Syrian electrical system or as part of the five countries interconnection project.
This study aims to analyze the effect of the wind farms on frequency stability of the electrical power network, and the description of the performance of Syrian Electrical Power System with integration of wind farms in several regions in Syria (Al-Q uenetera – Al-Hejana - Ghabagheb) through the evaluation of frequency stability of the power system and the Critical Clearing Time (CCT). The effect of wind farms on the frequency behavior of Syrian network and factors related will be investigated such as generation technology by replacing the power-generated source by two main types of induction generators, changing the location of wind farms and increasing gradually the rate of wind power. The simulation analysis will be applied on Syrian Electrical Power System 230KV – 400KV, by using program NEPLAN, which gives access to an extensive library of grid components, and relevant wind turbine model.
The out-of-stability state of synchronous generator which connected to high voltage network due to the transient situations which lead us to disconnect the generator causes finincial and technical problems. Therfore the purpose of this research i s to study the stability of synchronous generator working which connected to high voltage network through the transient situation.This research present the posibilty of returning the synchronous generator to synchronous-steadystate at the late time of the transient state when the load angle is in the out-of-stability zone through controling the rotor-excitation and increasing the generator’s electric motive force.This lead to increase the generator’s maximum power and to increase the generator’s stability-torque which lead to return the synchronous generator to synchronous-steadystate without need of discconecting it from network.Then put the mathmatical model.
The fluctuation of voltage cannot be tolerant for equipment in modern industrial plants such as lighting loads, PLC, robots, and another equipment, which exist in transmission and distribution systems, so we should use proper aids to regulate volta ge and control it. In this study a (± 25Mvar) Static Synchronous Compensator (STATCOM) is used to enhance voltage stability in a (66 kv, 1500MV.A) power transmission network. The STATCOM in this study regulates the voltage of the transmission network for changing in voltage (± 7%) from the nominal value. A model of the power transmission system and another model of the STATCOM device, which will enhance the stability of voltage are designed in MATLAB/Simulink. And the control of (STATCOM) is achieved by using a Proportional Integrative (PI) controller with Fuzzy Logic Supervisor to adjust the parameters in PI controller in DC voltage regulator during transient states of load changing which gives more stability in DC voltage. The results of the simulation are shown. This study demonstrates the ability of STATCOM for regulating the voltage of the transmission system by injecting and absorbing reactive power from the power system, and the DC voltage be more stability by using Fuzzy Logic supervisor.
comments
Fetching comments Fetching comments
Sign in to be able to follow your search criteria
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا