The out-of-stability state of synchronous generator which connected to high voltage network due to the transient situations which lead us to disconnect the generator causes finincial and technical problems. Therfore the purpose of this research is to study the stability of synchronous generator working which connected to high voltage network through the transient situation.This research present the posibilty of returning the synchronous generator to synchronous-steadystate at the late time of the transient state when the load angle is in the out-of-stability zone through controling the rotor-excitation and increasing the generator’s electric motive force.This lead to increase the generator’s maximum power and to increase the generator’s stability-torque which lead to return the synchronous generator to synchronous-steadystate without need of discconecting it from network.Then put the mathmatical model.

References used
A.John Wileyand، Isidor Kerzenbaum"Operration Maintenance of large turbo-gwnerators"IEEE،NEW YORK publication،2004
P.C.SEN -"Principles electrical machines and powerelectronics" second edition، New York -1996
EFANOF SAMALENSKE "Electrical Machines" Moscow، Mir publishers 1988
rate research

Read More

Efforts are being made to connect many wind farms to Syrian electrical network As of Wind turbine the increases; their Cumulative impact on dynamic operational characteristics of power system will increase. In this paper, the impact of constant spe ed wind turbines utilizing squirrel cage induction generators, the most worldwide spread nowadays, on the transient stability of Syrian power system is analyzed. Various aspects have been considered like wind turbine penetration level, fault location on power system overhead lines and network topology transforming. Results of this study show that wind turbine farms planned to be connected to Syrian electrical network will have significant impact in improving transient stability parameters (CCT,d). As the wind turbine penetration level increases, their impact will increase, but still remain dependent on the fault location and network topology transforming caused by double circuits of overhead lines.
Operating the electrical power systems at normal conditions is our goal always. This is what represents the ideal state of electrical power system work. Hence, the electrical power system work in case of insufficient electrical power requires avoid ing since it leads to big losses in national economy. These losses could be huge when we talk about connection borders between systems as per overload frame, because of lack of electrical power request. The impact of these conditions could be noticeably decreased at a reasonable limit of electrical power request. When we find out the optimal solution of electrical power systems operation and the communication lines between them while considering the losses of consumers disconnecting that guarantee the stability of loads. Finally, it is so at full use of maneuver (available cases) spare power properties when applying the instant correction of regime. This paper studies the basic approach to solve these issues which imply the reliability definitions.
The effect of two - mass system factors on the quality and quality of transient states , particularly the effect of mechanical rigidity has been studied in this research . Besides , mathematical expression which can calculate the optimal value of rigidity and provide the minimum extent of electromechanical vibrations have been obtained . Characteristics and schematic diagrams that prove the effect of mechanical rigidity on the behaviour of the transient state are illustrated . These methods help to improve the performance of automatic control systems in order to provide the minimum dynamic loads without reduction of the machine productivity.
Therefore in this paper we will present the stability analysis carried out on the Dwesat dam with vertical core, its high is 33m, the downstream slope of 1V:2.75H and the upstream slope of 1V:3.0H. Thickness of the vertical core was varied from 1V: 0.25H to 1V:2.0H, and also present the effect of the varied thickness on slope stability for both upstream and downstream under three design conditions i.e. during and end of construction, steady state seepage and rapid draw down by General Limit Equilibrium Method using GeoStudio software. It was observed from the analysis that by varying the thickness of vertical core of earth dam, thinner core up to 1V:1.30H gives more stability and further increase in thickness of core tends to sharp decline in factor of safety for both upstream and downstream slope under different design conditions.
Due to the large and rapid increase in the demand for electricity and the gradual decline of non-renewable sources of energy (fossil fuels, etc.), the performance of electrical systems has to be developed so the use of distributed generation and it s connection with the main networks is one of these methods but this linkage causes some problems like changing in electrical voltage. In this research a radial electric distribution system was simulated and studied the effect of distributed generation on electrical voltage stability -in static and dynamic state-and its effect when the generator is synchronous or induction.