يهدف هذا البحث إلى دراسة تخفيض تأثير الإهتزازات الناتجة أثناء عمل المطحنة العمودية
التي تقوم بطحن المواد الأولية اللازمة لإنتاج مادة الإسمنت في معمل إسمنت حماة الجديد
على أجهزة التحكم المركزي الواقعة في مبنى يبعد حوالي 100 متر عن هذه المطحنة ,
حيث أن زيادة شدة الإهتزاز تؤدي إلى اهتزاز الجوائز الحاملة لأجهزة التحكم و تسبب ضرر
في العناصر الإلكترونية.
This research drives at studying the reduction of vibration effect on
central control system located on about 100 m of the Vertical mill
running at New Hama Cement factory , which grinds raw materials
necessary for cement production ,Whereas , the increase of vibration
intensity leads to vibrate control Instruments beams and the electronic
elements will be damaged.
References used
FLSmidth Engineering company A/S., ( 2011). - ATOX raw mill . Copenhagen, Denmark
IBM International Business Machines Corporation., ( 2012). - PureFlex System-Planning for the system, Armonk, New York
Metwally H.M., Slman F.K., EL Lakany A.M., (1993). - An Improved Matrix Method for the Dynamic Response for Modeling Structure under Moving Vehicles . Proceeding in the International Modal Analysis Conference IMAC, Held in kissimmee, Florida, USA
The study aims to identify the effect of Physical and moral
incentives which provided to employees in the Cement's factory in
Tartous on their satisfaction on their work, and to shed some light
on the incentive systems applied to employees in that sector.
This research was performed to study the effect of sewage water on
the surface water of the Addelbeh Valley stream, and groundwater
on both sides of the stream in Tartous Cement Factory area.
Water samples were taken from the factory water outlet
This research deals with study and analysis the issue of adjust and control the production process by using the Quality Control Charts (Control Panels) for variables , in order to measure products quality during production process , by knowing deviat
Therefore in this paper we will present the stability analysis carried out on the
Dwesat dam with vertical core, its high is 33m, the downstream slope of 1V:2.75H and the
upstream slope of 1V:3.0H. Thickness of the vertical core was varied from 1V:
This research aims to:
Determination of optimal pH values to reach the highest
efficiency of chromium removal in industrial wastewater from
tanneries by chemical deposition.
Access to close concentration of the permitted
concentration of chromium in treated tannery wastewater
according to Syrian Standard No. 2580/2002 (Table 1).