This research aims to: Determination of optimal pH values to reach the highest efficiency of chromium removal in industrial wastewater from tanneries by chemical deposition. Access to close concentration of the permitted concentration of chromium in treated tannery wastewater according to Syrian Standard No. 2580/2002 (Table 1).


Artificial intelligence review:
Research summary
تهدف هذه الدراسة إلى تحديد القيم المثلى لدرجة الحموضة (pH) للوصول إلى أعلى كفاءة لإزالة معدن الكروم من مياه الصرف الناتجة عن عمليات الدباغة باستخدام الترسيب الكيميائي. تم إجراء سلسلة من التجارب على عينات مياه محضرة مخبرياً بتركيزات مشابهة لمياه الصرف الصناعية. شملت الدراسة تغيير درجة الحموضة باستخدام ماءات الكالسيوم (Ca(OH)2) ودراسة تأثيرها على كفاءة إزالة الكروم عند زمن ترسيب ثابت، بالإضافة إلى إضافة مادة مؤكسدة هيبوكلوريت الصوديوم (NaOCl) ودراسة تأثيرها. أظهرت النتائج أن أفضل كفاءة لإزالة الكروم تحققت عند قيمة pH = 9 باستخدام ماءات الكالسيوم، بينما تحسنت الكفاءة بشكل ملحوظ عند إضافة مادة مؤكسدة، حيث وصلت نسبة التخفيض إلى 92.36% عند pH = 8. توصي الدراسة باستخدام هذه الطريقة في محطات معالجة مياه الصرف الصناعية لمعامل الدباغة لفعاليتها وانخفاض تكلفتها.
Critical review
تعتبر هذه الدراسة خطوة هامة نحو تحسين معالجة مياه الصرف الصناعية، إلا أن هناك بعض النقاط التي يمكن تحسينها. أولاً، يجب أن تشمل الدراسة تأثير العوامل البيئية الأخرى مثل درجة الحرارة ونوعية المياه على كفاءة الترسيب الكيميائي. ثانياً، قد يكون من المفيد إجراء تجارب ميدانية للتحقق من نتائج التجارب المخبرية في ظروف واقعية. ثالثاً، يجب دراسة تأثير المواد الكيميائية المستخدمة على البيئة المحيطة بشكل أوسع لضمان عدم حدوث تلوث ثانوي. وأخيراً، يمكن تحسين الدراسة من خلال مقارنة الكفاءة الاقتصادية والبيئية لهذه الطريقة مع طرق معالجة أخرى.
Questions related to the research
  1. ما هو الهدف الرئيسي من هذه الدراسة؟

    الهدف الرئيسي هو تحديد القيم المثلى لدرجة الحموضة (pH) للوصول إلى أعلى كفاءة لإزالة معدن الكروم من مياه الصرف الناتجة عن عمليات الدباغة باستخدام الترسيب الكيميائي.

  2. ما هي المواد الكيميائية المستخدمة في التجارب؟

    تم استخدام ماءات الكالسيوم (Ca(OH)2) وهيبوكلوريت الصوديوم (NaOCl) في التجارب.

  3. ما هي أفضل قيمة pH لإزالة الكروم باستخدام ماءات الكالسيوم؟

    أفضل قيمة pH لإزالة الكروم باستخدام ماءات الكالسيوم هي 9.

  4. ما هي التوصيات التي قدمتها الدراسة؟

    توصي الدراسة بإقامة محطات معالجة تعتمد على الترسيب الكيميائي لمياه الصرف الصناعية لمعامل الدباغة، ودراسة إمكانية استرجاع معدن الكروم من المياه بواسطة عملية القلترة الدقيقة، وإجراء أبحاث علمية على نماذج مخبرية.


References used
(Chaalal O, Mustafiz S.; Thomaidis A.; Mamais M.R.; Dewaidar A, 2002. Heavy Metal Removal from tanneries.Italy, 24 (1043- 1051
Borchart, J. A. 1977.Viruses and Trace Contamination in Water and Wastewater. Ann Arbor Publisher, Inc. Michigan
Dickinsen, D. A, 1983. The chemistry of reduced sulfur species and their removal from ground water supplies. J. AWWA. 75(6): 298-309
rate research

Read More

In this work, the performance of batch electrocoagulation (EC) treatment using iron electrodes with monopolar and bipolar electrode configurations for trivalent chromium (Cr (III)) removal from a synthetic wastewater was investigated. The influence s of current density (from 2 to 25 mA/cm2) and initial metal concentration (from 100 to 250 mg/L) on the removal efficiency were explored in a batch stirred cell for monopolar and bipolar configurations. Removal of Cr (III) by EC process from aqueous solution with both monopolar and bipolar electrode configurations was a feasible process. For the initial Cr (III) concentration of 250 mg/L, almost complete removal (99.88%) of Cr (III) was noted after 20 min of EC in case of bipolar electrode arrangement at 25 mA/cm2 with 4.5 mmol/L of supporting electrolyte (Na2SO4) against 89.58% of Cr (III) removal for monopole electrode configuration. At the same electrolysis time, the power consumption was 47 and 15.3 kWh/m3 in case of monopolar and bipolar configuration respectively for the previous removal conditions.
The aim of this study is to investigate the performance of batch electro coagulation (EC) using iron electrodes with bipolar configuration for simultaneous removal of chromium (Cr3+) from synthetic wastewater. The influences of current density (from 2 to 25 mA/cm2), initial metal concentration (from 100 to 250 mg/L) and supporting electrolyte (0-12 mmol/L Na2SO4) on removal efficiency are explored in a batch stirred cell to determine the best experimental conditions. The results indicate that EC was very efficient to remove Cr3+ from the synthetic wastewater having an initial concentration of 250 mg/L of Cr3+ under the best experimental conditions. At the current density of 15 mA/cm2 with a total energy consumption of ∼18.5 kWh/m3, more than 98.7% removal value was achieved for Cr3+ after 20 min EC treatment. Time of 20 minutes EC treatment was chosen as optimum time to gain less than 4 mg Fe/L in the treated water.
This study was performed at three plants for sewage treatment in Syrian coastal villages: al-Hara, Murj-Muairban, and Hibbeat. Dry sludge samples were collected from drying sludge basins monthly, during the period October 2011-September 2012. We d epended on different global ways to isolate the eggs from the sludge (flotation, sedimentation, filtration through special sieves). The microscopic study results of the sediment showed the presence of 5 different species of the parasitic worm-eggs, belonged taxonomically to five different species of parasitic worms, two species belonged to Nematoda: Ascaris lumbricoides and Trichuris trichura, and three species belonged to Platyhelminthes: one species of them belonged to Trematoda: Schistosoma mansoni, and the other two species belonged to cestodes: Taenia saginata, and Diphyllobothrium latum. The average number of worms eggs isolated from the dry sludge resulting from the three studied sewage treatment plants (al-Hara, Murj-Muairban, and Hibbeat) recorded relatively close values, the most number in the dry sludge resulting from the treatment plant in Hibbeat with an average 97.16% eggs/50g, then al-Hara with an average 75.08egg/50g dry sludge. Also the results showed that the isolated eggs were more diversed in Hibbeat treatment plant, this an indicator of the health status of the population in the studied sites. Study showed that the number and diversity of parasitic worm – eggs use more observed in Summer and Autumn than in Winter and Spring.
In this work, the performance of batch electrocoagulation (EC) treatment using iron electrodes with monopolar configuration for trivalent chromium (Cr3+) removal from a synthetic wastewater was investigated. The influences of current density (from 2 to 25 mA/cm2) and initial metal concentration (from 50 to 250 mg/L) on the removal efficiency were explored in a batch stirred cell to determine the best experimental conditions.
The big value of dams in the Syrian coast comes from using them for irrigation and sometimes as source of potable water. This study aimed to determine some chemical indicators of water quality in Lattakia dams during ten years (2002-2011). The conce ntrations of ions (Cl-1, SO4-2, NO2-1, NO3-1, PO4-3, K+1, Na+1) in five dams (Balloran, 16 Tishreen, Al-thawra, Alsafarkia and Alhweez) were studied. The results indicated that most of the ions showed significant difference in concentrations during 2002-2011.The ions concentrations in most studied dams increased. The increase related to characteristics of dams (location, capacity, the activities located around the dam…).