Do you want to publish a course? Click here

A new spectrophotometric analytical reagent for determination of Fe(III)

كاشف تحليلي جديد لتعيين الحديد الثلاثي طيفياً

2467   1   35   0 ( 0 )
 Publication date 2006
  fields Chemistry
and research's language is العربية
 Created by Shamra Editor




Ask ChatGPT about the research

This paper outline a new, simple, selective and sensitive spectrophotometric procedure for the quantitative determination of iron. The bidentate ligand of 2- (1-Acetyl-2-oxopropyl)acrylonitrile has been synthesized ,and determined by elemental analysis and infrared spectroscopy. The compound reacts with Fe(III) to form a colored complex with an absorption maxima at 400nm and 490nm. The effect of pH, amount of reagent, time, temperature and the interference of many ions on the Fe (III) determination was also estimated. Beer's law is obeyed for iron concentration in the range (0.23- 4.48μg/ ml) for spectrophotometric method and (0.56-8.4) for extraction spectrophotometric method. The molar absorptivity was in the rang 2.70x104-3.46 x 104 L.mol-1cm-1. Sandall's sensitivity was found to be 1.61 x 10 -3 – 2.07 x 10-3 μg . cm-2. The RSDs for both spectrophotometric and extraction spectrophotometric methods were below 3%. The analytical error SD/√n was within 0.021. The technique has been applied to the determination of iron in alloys and in pharmaceutical preparations.

References used
Kiran, T. N. and Revanasiddappa, H. D. (2003). Rapid and Sensitive Spectrophotometric Determination of Trace Amounts of Iron (III) Using Leuco Xylene Cyanol FF. Analytical and Bioanalytical Chemistry. 376, 1126 – 1130
Chacaroli,C.J.,Rade,J.F., Guimaraes, O. M., Balbo, V. R., Venezuela, C. S. and Teruel, F. S. (2000). Spectrophotometric Study of Iron Oxidation in the Iron(II) /Azide/ Tetrahydrofuran System and Some Analytical Applications. Anal Chem. Acta.411, 217-222
Ohno, S., Teshima, N., Zhang, H., and SAKA T. (2003). Utilization of Activating and Masking Effects by Ligands for Highly Selective Catalytic Spectrophotometric Determination of Copper and Iron in Natural Waters. Talanta. 60, 1177-1185
rate research

Read More

Direct high sensitive spectrophotometric method for determination Ni(III) has been suggested . proposed method is based on the formation of red- win colored complex between Ni(III) and DMG reagent in strong alkaline media of NaOH ,pH=12.5.the formed complex absorbed electromagnetic radiation at 465nm .
In this study, a new poly(vinyl chloride) (PVC) membrane electrode for La3+ ion based on paraldyhed phenyl hedrazon as an electroactive material was prepared.This electrode revealed good selectivity for La3+ over a wide variety of other metal ions. E ffects of experimental parameters such as membrane composition, nature and the amount of plasticizer, the amount of additive on the potential response of La3+ electrode were investigated. The electrode exhibited a Nernstian slope of 20.0±1.0mV per decade of La3+ over a concentration range of 1×10-7 to 1×10-1M of La3+ in the pH range 3.8–8.0. The response time was about 30 s and the detection limit was 7×10-8 M. The electrode couldbe used for at least one month without a considerable divergence in potential. The proposed electrode was used for the determination of lanthanum in a standard solations andwas successfully applied as an indicator electrode for potentiometric titration of La3+ with EDTA.
The spectral characteristics of the iron(III) lactate complexes were examined by the spectrophotometric methode, and the absorbance of these complexes has been studied at diferente wavelengthes . The stoichiometry of the photoreactive complex formed in the iron(III)-lactate system has been investigated in aqeuous solution under determinative experimental conditions. Initial concentrations whether of Iron(III) or of lactic acid ranged from to , and -values were belonging to the range . The results showed, that the ratio of iron(III) to lactate in the photoreactive complex is 1:2, i.e. its formula is . This complex has a maximum absorption at 365 nm. Its molecular absorption coefficient is about ≈ and its dissociation constant is about . The tentative mechanism for the photochemical decomposition of the complex has been suggested, in agreement with the reference studys . The suggested mechanism depends on the relationship between the absorbance and the photoreaction kinetics, and it is not based on the qualitative or quantitative analysis of reaction products.
In this research, we derived a non–paralyzable dead time equation shows the relation between the dead time and those factors. This equation shows the dead time as function of the applied voltage, pressure, temperature, dimensions of counter tube and type of the gas.
New, accurate, sensitive and reliable kinetic spectrophotometric method for the assay of fluvastatin sodium (FVS) in pure form and capsules has been developed. The method involves the oxidative coupling reaction of FVS with 3-methyl-2-benzothiazolinone hydrazone hydrochloride monohydrate (MBTH) in the presence of Ce(IV) in an acidic medium to form colored product with lambdamax at 615 nm.
comments
Fetching comments Fetching comments
Sign in to be able to follow your search criteria
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا