The study was carried out to remove of heavy metals (V+5, Ni+2) under static conditions from aqueous solutions by Syrian Zeolite mineral extracted from south of Syria. The results revealed that operational conditions such as initial solution pH and concentration, adsorbent particle size, the presence of competing cations, are able to affect the adsorption capacity and efficiency of natural zeolite.

References used
Nicholas,P.C. ; Paul,R. )2009(.Best Practices in the Petroleum Industry .Handbook of Pollution Prevention and Cleaner Prodection. ELSEVIER, P 45-47
Afshin, P.; Toraj, M. (2008) Wastewater treatment of desalting units. Desalination, Volume222,Issues 1-3,P 249–254
Namasivayam C. and Sangeetha, D. (2006). “Removal and recovery of vanadium (V) by adsorption onto ZnCl2 activated carbon: Kinetics and isotherms,” Adsorption, vol. 12 , pp. 103-117

Artificial intelligence review:
Research summary
تناولت الدراسة استخدام الزيوليت الطبيعي المستخرج من جنوب سوريا لإزالة أيونات الفاناديوم والنيكل من المياه الصناعية. أظهرت النتائج أن شروط التشغيل مثل درجة الحموضة (pH) والتركيز الأولي للمحلول وحجم حبيبات الزيوليت ووجود الشوارد التنافسية تؤثر على سعة وفعالية الامتزاز. تم تحديد الزمن اللازم للوصول إلى التوازن بـ 6 ساعات، وكانت فعالية الزيوليت في الامتزاز أعظمية عند pH=6. أظهرت الدراسة أن هناك مراكز امتزاز فردية للزيوليت لكل معدن، حيث كانت سعة الامتزاز القصوى للفاناديوم 40 mg/g وللنيكل 27.19 mg/g. استخدمت نماذج لانغموير وفريندليتش لتقييم أداء الامتزاز وأظهرت ملاءمة جيدة مع البيانات التجريبية، مع أفضلية لنموذج لانغموير. تم التحقق من تأثير عدة عوامل مثل حجم الحبيبات وتركيز المحلول الأولي ودرجة الحموضة والشوارد التنافسية على فعالية الامتزاز. أظهرت النتائج أن الزيوليت الطبيعي يمتلك كفاءة عالية في إزالة الفاناديوم والنيكل من المحاليل أحادية المكون، مع تأثير ضئيل للشوارد التنافسية وشوارد الكالسيوم على فعالية الامتزاز.
Critical review
دراسة نقدية: الدراسة قدمت نتائج مهمة حول استخدام الزيوليت الطبيعي في إزالة المعادن الثقيلة من المياه الصناعية، ولكن هناك بعض النقاط التي يمكن تحسينها. أولاً، الدراسة لم تتناول تأثير العوامل البيئية الأخرى مثل درجة الحرارة والضغط على فعالية الامتزاز. ثانياً، لم يتم اختبار فعالية الزيوليت في ظروف ديناميكية مثل تدفق المياه عبر عمود امتزاز، مما قد يؤثر على النتائج عند التطبيق العملي. ثالثاً، الدراسة اعتمدت على محاليل أحادية المكون، بينما المياه الصناعية تحتوي عادة على مزيج معقد من الملوثات، لذا يجب إجراء تجارب إضافية للتحقق من فعالية الزيوليت في هذه الظروف. أخيراً، لم تتناول الدراسة تكلفة الإنتاج والتطبيق العملي للزيوليت، وهو عامل مهم لتقييم جدوى استخدامه على نطاق واسع.
Questions related to the research
  1. ما هي العوامل التي تؤثر على فعالية امتزاز الزيوليت الطبيعي للمعادن الثقيلة؟

    العوامل التي تؤثر على فعالية امتزاز الزيوليت الطبيعي تشمل درجة الحموضة (pH)، التركيز الأولي للمحلول، حجم حبيبات الزيوليت، ووجود الشوارد التنافسية.

  2. ما هي سعة الامتزاز القصوى للزيوليت الطبيعي لكل من الفاناديوم والنيكل؟

    سعة الامتزاز القصوى للزيوليت الطبيعي هي 40 mg/g للفاناديوم و27.19 mg/g للنيكل.

  3. ما هي النماذج الرياضية المستخدمة لتقييم أداء الامتزاز في الدراسة؟

    تم استخدام نماذج لانغموير وفريندليتش لتقييم أداء الامتزاز، وأظهرت النتائج ملاءمة جيدة مع البيانات التجريبية، مع أفضلية لنموذج لانغموير.

  4. ما هو الزمن اللازم للوصول إلى التوازن في عملية الامتزاز باستخدام الزيوليت الطبيعي؟

    الزمن اللازم للوصول إلى التوازن في عملية الامتزاز باستخدام الزيوليت الطبيعي هو 6 ساعات.

rate research

Read More

The study was carried out on the sorption of heavy metals (Pb+2, Zn+2) under static conditions from single- and multicomponent aqueous solutions by Syrian Zeolite mineral extracted from south Syria. The removal has an ion-exchange nature and consis ts of three stages: the adsorption on the surface of microcrystals, the inversion stage, and the moderate adsorption in the interior of the microcrystal, The study showed that equilibrium time is 6 hours, and The slight difference between adsorption capacity of the Zeolite toward lead, zinc from single- and multicomponent solutions may testify to individual sorption centers of the zeolite for each metal. The maximum sorption capacity toward pb2+ is determined as 33.89 mg/g at an equilibrium concentration of 261.07 mg/L and toward Zn+2 as 29.18 mg/g at 309.818 mg/L. Langmuir and Freundlich Adsorption Isotherms were used to evaluate natural zeolite adsorption performance for Lead, Zinc. These Isotherms were able to provide suitable fit with experimental data, the factor R2 ranged between 0.95 – 0.99, with better fit to Langmuir Isotherm.
Fixed bed adsorption columns packed with natural zeolite were used to study the kinetics of heavy metals removal from the single component solutions of Vanadium, Nikle, Zinc, and Lead. The system parameters studied include solution flow rate and be d height. The effect of competing cations was also studied to establish the effectiveness of natural zeolite in treating Industrial wastewater under continuous conditions using fixed bed columns. The metal loaded natural zeolite was regenerated using NaCl . The results from column studies showed that the Slower flow rates gave better removal efficiencies compared to faster ones, Longer bed heights also resulted in greater adsorption efficiencies. The bed depth service time (BDST) model was successfully used to simulate experimental results at 30 % breakthrough. This model provides the necessary parameters needed for fixed bed column design, the factor R2 ranged between 0.91 – 0.95. Natural zeolite was exposed to 3 cycles of adsorption and desorption. The efficiency of the column in removing heavy metals was high, The results indicate that natural zeolite can be regenerated and re-used in removing heavy metals from solution.
The Syrian natural zeolite from om'ozon area has been studied as adsorbent for Ni(II) ions from aqueous solution. The removal of Ni(II) ions under different conditions was studied adsorption of Ni(II) enhanced with an increase of initial concentratio n, temperature and PH .all experiments were carried out at contact time 6h. The amount of Ni(II) adsorption was increased from 16.36 mgNi/g for initial solution concentration of 100mg Ni/l to 71.33 mgNi/g (for C0=1000mgNi/L). The experimental data fitted well to Langmuir isotherm. The maximum capacity was qmax=142.85mgNi/g Adsorption amount at 298K varies from 16.36mgNi/g for initial solution concentration of 100mg Ni/l to 47.93mg Ni/g(for C0=400mgNi/L) and it increases at 333K to 16.65 mgNi/g and 51mgNi/g (for C0=100 and 400 mg Ni/L )respectively. The adsorption of Ni(II) ions was increased by increasing PH up to ~ 5 and then stabilized up to PH=6 and after that the precipitation process was accured.
Syrian natural zeolit was used to study the adsorption of phenol from aqueous solutions. Batch method was used to study the adsorption process. The results showed that the adsorption process accurs rabidly at the first time and the equilibrium ach ieved after 120min . The adsorption process performed in the rang of PH (3-10). The adsorption of phenol increased by increasing of PH value up to(6-7) and then decreased. The temperature affect the adsorption process and the results showed that the increasing of the temperature leads to decreasing of the adsorption of phenol.The maximum adsorption amount of phenol was 8 mg/g at 25C0 when the initial concentration of phenol was 60mg/l. Adsorption amount of phenol increased when the adsorbent dosage increased up to 0.3g of zeolite. The resulted data of the adsorption isotherm were fitted with Langmuire model and the monomolecular layer adsorption formed on the surdace of the adsorbent.
In this work the process of removal of zinc ions from aqueous solutions was studied using natural Syrian zeolite. Two samples were used: natural zeolite Z and modified zeolite with NaCl solution Z-Na. The removal percentage of zinc ions vs. time was determined using differential initial concentrations of Zn+2: 50,100,200,300,400 mg/L. The contact time was determined and it was 360 min. The removal of Zn+2 ions as a function of temperature and pH have been studied. It was found the increasing of removal percentage by increasing temperature and increasing when pH increasing up to ~7,then the precipitation of zinc hydroxide accurse. The Langmuire adsorption isotherm equation used to calculate the maximum sorption capacity and it was 21.7 and 28.5 mg/g for Z and Z-Na respectively. Results indicate a significant potential for the natural and modified zeolite as an adsorbent/ion-exchange materials for heavy metal removal.
comments
Fetching comments Fetching comments
Sign in to be able to follow your search criteria
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا