Do you want to publish a course? Click here

Automated Generation of Accurate \& Fluent Medical X-ray Reports

الجيل الآلي من تقارير دقيقة من الأشعة السينية الطبية الدقيقة

322   0   0   0.0 ( 0 )
 Publication date 2021
and research's language is English
 Created by Shamra Editor




Ask ChatGPT about the research

Our paper aims to automate the generation of medical reports from chest X-ray image inputs, a critical yet time-consuming task for radiologists. Existing medical report generation efforts emphasize producing human-readable reports, yet the generated text may not be well aligned to the clinical facts. Our generated medical reports, on the other hand, are fluent and, more importantly, clinically accurate. This is achieved by our fully differentiable and end-to-end paradigm that contains three complementary modules: taking the chest X-ray images and clinical history document of patients as inputs, our classification module produces an internal checklist of disease-related topics, referred to as enriched disease embedding; the embedding representation is then passed to our transformer-based generator, to produce the medical report; meanwhile, our generator also creates a weighted embedding representation, which is fed to our interpreter to ensure consistency with respect to disease-related topics. Empirical evaluations demonstrate very promising results achieved by our approach on commonly-used metrics concerning language fluency and clinical accuracy. Moreover, noticeable performance gains are consistently observed when additional input information is available, such as the clinical document and extra scans from different views.



References used
https://aclanthology.org/
rate research

Read More

Radiology report generation aims at generating descriptive text from radiology images automatically, which may present an opportunity to improve radiology reporting and interpretation. A typical setting consists of training encoder-decoder models on image-report pairs with a cross entropy loss, which struggles to generate informative sentences for clinical diagnoses since normal findings dominate the datasets. To tackle this challenge and encourage more clinically-accurate text outputs, we propose a novel weakly supervised contrastive loss for medical report generation. Experimental results demonstrate that our method benefits from contrasting target reports with incorrect but semantically-close ones. It outperforms previous work on both clinical correctness and text generation metrics for two public benchmarks.
Inspired by Curriculum Learning, we propose a consecutive (i.e., image-to-text-to-text) generation framework where we divide the problem of radiology report generation into two steps. Contrary to generating the full radiology report from the image at once, the model generates global concepts from the image in the first step and then reforms them into finer and coherent texts using transformer-based architecture. We follow the transformer-based sequence-to-sequence paradigm at each step. We improve upon the state-of-the-art on two benchmark datasets.
This research could be considered as a continuous study of luminescence spectrum of praseodymium cascade photon emission Pr3+ of 1% ions effect on Li2YB5O10 and LaF3 crystals. The Li2YB5O10 crystal shows many spectrum peaks, mainly of 272nm and 300nm wavelengths of luminescence decay τ=10.6 ns. The other crystal LaF3 shows two sharp spectrums of 478.6nm and 485.5nm wavelengths, which are due to the energetic transitions of 3P0→3H4 of luminescence decay τ=1.8 ns. This study proves that these two crystals exhibit good luminescence properties as promising compounds for laser and medical equipments to be used in radiation detectors and other research domains. The measurements were done in Tech-governmental University of Petersburg, Russia, 2008.
In this work we carried out some numerical experiments on NX2, UNU/ICTP PFF dense plasma focus device with neon filling gas using Lee code version (RADPFV5.15de.c1) and standard parameters of the devices to compare the value of the soft x-ray yiel d (Ysxr) emitting from each one. Also we studied the influence some factors on the value of (Ysxr).
The Lee code is applied to characterize the plasma focus in two plasma focus devices UNU/ICTP PFF and Amirkabir plasma focus device (APF), and for optimizing the nitrogen soft x-ray yields based on bank, tubes and operating parameters. It is foun d that the soft x-ray yield increases with changing pressure until it reaches the maximum value for each plasma focus device, with keeping the bank parameters, operational voltage unchanged but systematically changing other parameters.

suggested questions

comments
Fetching comments Fetching comments
Sign in to be able to follow your search criteria
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا