In this work we carried out some numerical experiments on NX2, UNU/ICTP PFF dense plasma focus device with neon filling gas using Lee code version (RADPFV5.15de.c1) and standard parameters of the devices to compare the value of the soft x-ray yield (Ysxr) emitting from each one. Also we studied the influence some factors on the value of (Ysxr).


Artificial intelligence review:
Research summary
تتناول هذه الدراسة تنفيذ تجارب عددية باستخدام برنامج Lee الحاسوبي لدراسة مردود الأشعة السينية اللينة في جهازي البلازما المحرقية الكثيفة UNU/ICTP PFF و NX2 عند استخدام غاز النيون. تم تحديد البارامترات الأساسية للجهازين ودراسة تأثير عدد من العوامل على قيمة المردود. أظهرت النتائج أن جهاز NX2 يحقق مردودًا أعلى للأشعة السينية اللينة مقارنة بجهاز UNU/ICTP PFF. كما تم مقارنة النتائج العددية مع النتائج التجريبية ووجد توافق كبير بينهما، مما يؤكد فعالية برنامج Lee كأداة لدراسة البلازما المحرقية الكثيفة.
Critical review
تعتبر هذه الدراسة مفيدة في توضيح فعالية برنامج Lee في دراسة مردود الأشعة السينية اللينة في أجهزة البلازما المحرقية الكثيفة. ومع ذلك، يمكن تحسين الدراسة من خلال تضمين مزيد من التفاصيل حول الشروط التجريبية المستخدمة في المقارنات التجريبية. كما يمكن توسيع نطاق الدراسة لتشمل غازات تشغيل أخرى ودراسة تأثير العوامل المختلفة بشكل أعمق.
Questions related to the research
  1. ما هو الهدف الرئيسي من الدراسة؟

    الهدف الرئيسي من الدراسة هو إجراء مقارنة بين جهازي البلازما المحرقية الكثيفة UNU/ICTP PFF و NX2 من ناحية مردود الأشعة السينية اللينة والعوامل المؤثرة على هذا المردود باستخدام برنامج Lee الحاسوبي.

  2. ما هي العوامل التي تم دراستها في البحث؟

    تم دراسة تأثير عدد من العوامل على مردود الأشعة السينية اللينة، مثل التيار الكلي، تيار القبضة، السرعات، درجة حرارة القبضة، كثافة الأيونات، نصف قطر القبضة، وطول القبضة مع تغيّر ضغط غاز النيون.

  3. ما هي النتائج الرئيسية التي توصلت إليها الدراسة؟

    توصلت الدراسة إلى أن جهاز NX2 يحقق مردودًا أعلى للأشعة السينية اللينة مقارنة بجهاز UNU/ICTP PFF، وأن كفاءة المردود بالنسبة لطاقة الجهاز تكون أعلى في جهاز NX2.

  4. كيف تم التحقق من فعالية برنامج Lee في الدراسة؟

    تم التحقق من فعالية برنامج Lee من خلال مقارنة النتائج العددية التي تم الحصول عليها باستخدام البرنامج مع النتائج التجريبية التي تم الحصول عليها من تجارب سابقة، ووجد توافق كبير بين النتائج العددية والتجريبية.


References used
LEE.S et al, 2010- A Course On Plasma Focus Numerical Experiments, ICTP-IAEA Workshop on Dense Magnetized Plasmas and Plasma Diagnostics . Italy,Trieste,300p
LEE.S et al,1998- "sxr lithography using a high performance plasma focus source". ICPP & 25th EPS Conference on Controlled
RAWAT.R et al, 2005-"Soft X-ray Imaging using a Neon Filled Plasma Focus X-ray, Source Journal of Fusion Energy". vol. 23, No. 1.DOI: 10.1007/s10894-004-1871-5
rate research

Read More

The Lee code is applied to characterize the plasma focus in two plasma focus devices UNU/ICTP PFF and Amirkabir plasma focus device (APF), and for optimizing the nitrogen soft x-ray yields based on bank, tubes and operating parameters. It is foun d that the soft x-ray yield increases with changing pressure until it reaches the maximum value for each plasma focus device, with keeping the bank parameters, operational voltage unchanged but systematically changing other parameters.
The measurement of pulsed current by the Rogowski coil method is described. The current transformer with a large number of turns terminator has good short-time response, necessary for the sharp current dip region
We have studied in this paper, investigated the influence of an electron beam on a dense warm inhomogeneous plasma, and the instability resulting in this system, through studying of the influence of plasma density variation on the beam-plasma insta bility growth. Where we considered the plasma density is in the same order of Fermi gas, and we considered the model of homogeneous cold beam-inhomogeneous warm plasma system, with small phase velocity in compared with the case of existence of an external magnetic field. We derived the differential equations that describe this system in the case of collision plasma because of its high density, and we derived the differential equation that expresses the energy absorbed in the wholesale and we solved this equation then we drew the suitable graphics using Mathcad program, discussed, and analyzed the results that we reached. Results indicated an amplification of outcome waves in wholesale because of the absorbed energy and instability increasing in the system.
Radiology report generation aims at generating descriptive text from radiology images automatically, which may present an opportunity to improve radiology reporting and interpretation. A typical setting consists of training encoder-decoder models on image-report pairs with a cross entropy loss, which struggles to generate informative sentences for clinical diagnoses since normal findings dominate the datasets. To tackle this challenge and encourage more clinically-accurate text outputs, we propose a novel weakly supervised contrastive loss for medical report generation. Experimental results demonstrate that our method benefits from contrasting target reports with incorrect but semantically-close ones. It outperforms previous work on both clinical correctness and text generation metrics for two public benchmarks.
We investigate the influence of the variable plasma density on the spatial growth of the beam-plasma instability, considering the model of homogeneous cold beam-inhomogeneous warm plasma system under the condition of the smallness of phase velocit y of waves compared to the beam velocity. We determine a direction of the beam with unmagnatized plasma. Considering a one – dimensional electrostatic oscillation when the directions of beam propagation, plasma density gradient and wave electric field coincide with X-axis. To formulate mathematical equation of beam and plasma then we make studying equation linearized, and then study the continuity equation and boundary conditions. Formulating electric field density then study a case in which a plasma is collisional because of its high density and the temperature .Finally we drive absorbent energy and find solutions of these equations then draw it.

suggested questions

comments
Fetching comments Fetching comments
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا