Do you want to publish a course? Click here

Clinical Evaluation of four Interocclusal Recording Materials in Partial Edentulous Cases

التقييم السريري لأربع مواد تسجيل للعلاقات الإطباقية في حالات الدرد الجزئي

927   0   7   0 ( 0 )
 Publication date 2011
  fields Dentistry
and research's language is العربية
 Created by Shamra Editor




Ask ChatGPT about the research

The selection of recording material is an important factor to be considered in making interocclusal records. Many materials are available to record interocclusal relations , but they differs in their accuracy during mounting the casts on the articulator. Purpose: The purpose of the study was to compare of four interocclusal recording materials in their effect on the relationship of the casts, and to determine the most accurate material.

References used
Tripodakis AP, Vergos VK, Tsoutsos AG. Evaluation of the accuracy of interocclusal records in relation to two recording techniques. J Prosthet Dent 1997;77:141-6
Small BW. Centric relation bite registration. Gen Dent 2006 ;54:10-11
Pagnano VO, Bezzon OL, Mattos MGC, Ribeiro RF. A clinical evaluation of materials for interocclusal registration in centric relation. Braz Dent J 2000;11:41-47

rate research

Read More

To evaluate the rapid immuno-chromotographic assay ICT based on antigen 38 Kda of Mycobacterium tuberculosis, sera was collected from 245 persons, 111 of them were pulmonary TB patients, 69 extrapulmonary, 25 having non TP respiratory diseases, an d 30 healthy control persons. The diagnosis were based on usual testes such as signs and symptoms, X-ray, smear and biopsy as well as the using of the serological test ICT the results were as follows: When pulmonary TB smear positive ICT was positive in 50 of 55 patients (sensitivity 91%) whereas in pulmonary TB smear negative, sensitivity of ICT was 86 % (48/ 56). The sensitivity of the assay in extra-pulmonary TB patients was 74% (51/69) and the sensitivity of the test in all TB types was 83% (149/ 180) and specificity of the test in nonTB pulmonary diseases were 96% and 100%in healthy persons.
the purpose of this study to evaluate early implant success of small-diameter 2.5mm one-stage dental implants immediately loading in congenital missing of maxillary lateral incisor cases associated with limited interdental space and mesial and distal bone loss after one year of loading.
The cases of foreign body aspiration constitute a significant proportion of emergency cases that present to emergency departments around the clock. These cases demand quick management and wisdom to decide the therapeutic procedure, in order to achi eve a delicate balance between the need for endoscopy on the one hand and the complications due to endoscopy or the delay of it on the other hand. The possibility of reaching an algorithm based on a combinatorial approach that encompasses evaluation of clinical findings along with investigations will help to increase the accuracy of decision making process and reduce complications. To outline helpful measures in the management of suspected cases of foreign-body aspirations in order to increase the accuracy of bronchoscopy indications, and thus decrease negative bronchoscopies and also reduce morbidity and mortality associated with suspected aspiration’s cases.
New resin systems( di-methacrylates) were developed to improve the mechanical and physical properties of provivinal to investigate mechanical srength(edge- strength, diametrical tensile strength) and polymrrization(degree of conversion) of three newdi-methacrylates provisionals, and one of mono-methacrylate.

suggested questions

comments
Fetching comments Fetching comments
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا