Comparison Study of separation and deformation of stainless steel and Nickel-Titanium hand instruments and changing of working length during preparation of curved root canals of extracted teeth

دراسة مقارنة انكسار و تشوّه أدوات السّتانلس السّتيل و أدوات النّيكل تيتانيوم اليدويّة مع تغيّر طول العمل أثناء تحضير الأقنية الجذريّة المنحنية في الأسنان المقلوعة

1970   0   103   0 ( 0 )
 Publication date 2015
and research's language is العربية
 Created by Shamra Editor




Ask ChatGPT about the research

Aim: to compare NiTi hand instruments with Stainless- steel instruments according to separation, deformation and changing of working length during preparation of curved root canal in extracted teeth. Materials and Methods: 24 of curved root canal were randomly divided into two groups. One group was prepared using stainless steel instruments and the other prepared by NiTi instruments. Separation and deformation of the two hand instrument systems were determined and the changing of working length during preparation were registered and compared. Data were collected and stastical analysis were conducted. Results: Stainless steel system showed more separated and deformed instruments, but there were no significant differences between two systems. Also, change of working length was happened with stainless steel only but without significant differences with NiTi. Conclusion: under the conditions of this study, it can be concluded that two hand instrumentation systems separated and deformed with no differences . However, working length was changed during use stainless steel but without differences between two system.


Artificial intelligence review:
Research summary
تهدف هذه الدراسة إلى مقارنة الأدوات اللبية اليدوية المصنوعة من الستانلس ستيل وتلك المصنوعة من النيكل تيتانيوم من حيث انكسارها وتشوهها وتغير طول العمل أثناء تحضير الأقنية الجذرية المنحنية في الأسنان المقلوعة. تم اختيار 24 سنًا بشريًا مقلوعًا مع قناة منحنية واحدة على الأقل، وتم تقسيمها إلى مجموعتين: الأولى تم تحضيرها بأدوات الستانلس ستيل والثانية بأدوات النيكل تيتانيوم. أظهرت النتائج أن هناك تغيرًا في طول العمل في ثلاثة أسنان تم تحضيرها بنظام الستانلس ستيل، بينما لم يحدث أي تغير في طول العمل أثناء التحضير بنظام النيكل تيتانيوم، ولكن لم يكن هناك فرق ذو دلالة إحصائية بين النظامين. كما لم يكن هناك فرق ذو دلالة إحصائية من حيث انكسار الأدوات أو تشوهها، على الرغم من أن عدد الأدوات المكسورة والمشوهة كان أكبر في نظام الستانلس ستيل. بناءً على هذه النتائج، يمكن القول إنه لا يوجد فرق بين الأدوات اللبية اليدوية المصنوعة من الستانلس ستيل وتلك المصنوعة من النيكل تيتانيوم من حيث التغير في طول العمل أو عدد الأدوات المكسورة أو المشوهة أثناء تحضير الأقنية الجذرية المنحنية.
Critical review
دراسة نقدية: تعتبر هذه الدراسة خطوة مهمة في مجال طب الأسنان، حيث تقدم مقارنة شاملة بين نوعين من الأدوات اللبية المستخدمة في تحضير الأقنية الجذرية المنحنية. ومع ذلك، هناك بعض النقاط التي يمكن تحسينها. أولاً، حجم العينة كان صغيرًا نسبيًا (24 سنًا فقط)، مما قد يؤثر على قوة النتائج وإمكانية تعميمها. ثانيًا، لم يتم دراسة فعالية التنظيف للأدوات المختلفة، وهو جانب مهم يجب أخذه في الاعتبار عند تقييم الأدوات اللبية. ثالثًا، كان من الأفضل إجراء الدراسة في ظروف سريرية حقيقية بدلاً من الأسنان المقلوعة فقط، لتقديم نتائج أكثر واقعية. وأخيرًا، يجب أن تكون هناك توصيات أكثر تفصيلًا حول كيفية تحسين استخدام الأدوات المختلفة في الممارسة السريرية اليومية.
Questions related to the research
  1. ما هو الهدف الرئيسي من هذه الدراسة؟

    الهدف الرئيسي هو مقارنة الأدوات اللبية اليدوية المصنوعة من الستانلس ستيل وتلك المصنوعة من النيكل تيتانيوم من حيث انكسارها وتشوهها وتغير طول العمل أثناء تحضير الأقنية الجذرية المنحنية في الأسنان المقلوعة.

  2. ما هي النتائج الرئيسية التي توصلت إليها الدراسة؟

    النتائج الرئيسية هي أنه لا يوجد فرق ذو دلالة إحصائية بين الأدوات المصنوعة من الستانلس ستيل وتلك المصنوعة من النيكل تيتانيوم من حيث التغير في طول العمل أو عدد الأدوات المكسورة أو المشوهة أثناء تحضير الأقنية الجذرية المنحنية.

  3. ما هي المواد والأساليب المستخدمة في هذه الدراسة؟

    تم اختيار 24 سنًا بشريًا مقلوعًا مع قناة منحنية واحدة على الأقل، وتم تقسيمها إلى مجموعتين: الأولى تم تحضيرها بأدوات الستانلس ستيل والثانية بأدوات النيكل تيتانيوم. تم تقييم الأدوات بعد التحضير من حيث انكسارها وتشوهها وتغير طول العمل.

  4. ما هي التوصيات التي قدمتها الدراسة لتحسين البحث المستقبلي؟

    التوصيات تشمل إجراء دراسات على حالات سريرية حقيقية، اختيار عينات محددة من حيث درجة الانحناء لتقليل الانحراف المعياري، وإجراء دراسات مقارنة لفعالية التنظيف بين الأدوات المختلفة.


References used
PETERS,OH. SHONENBERGER,K. LAIB,A. Effect of four NI-TI preparation technique on root canal geometry assessed by micro computed tomography .International Endodontic Journal. 2001, 34, 221-230
SCHILDER,H. Cleaning and shaping the root canal. Dent Clin North Am. 18, (1974), 269-296
SCHILDER,H. YEE,FAS. Canal debridement and disinfection . in : COHEN,S ET AL Pathway of the pulp 3rdEditionn. 1984, 175-204
rate research

Read More

Aim: to compare the shaping ability of NiTi hand instruments with Stainless- steel instruments in preparation of curved root canal in extracted teeth. Materials and Methods: a total of 24 of curved root canal were randomly divided into two groups. O ne group was prepared using stainless steel instruments and the other prepared NiTi instruments. Curvatures pre-and post instrumentation were registered and compared. And straightening of the canals were determined by autocad analysis system. Results: two systems were significantly changed the original canal curvature with no differences between both systems. However, the time required to finish preparation was significantly less with NiTi system. Conclusion: under the conditions of this study, it can be concluded that two hand instrumentation system changed the original canal curvature, but the time consuming to finish the preparation was less with NiTi hand system.
Aim: to compare the shaping ability of two rotary systems (Protaper Universal and Protaper Next) and K-file hand instruments in curved root canals of extracted human molars. Materials and methods:Thirty extracted molars with curved canals were cho sen. The curvature of root canals was determined (15-40o) then the sample was randomly divided into three groups: n1=n2=n3=10. Group(1): was prepared using K-file hand instruments (Stand), group(2): prepared by Protaper Universal (PTU), whereas group3: prepared by Protaper Next (PTN).The curvature after preparation and Time preparationwere evaluated. Data were collected and statistical analysis was conducted. Results: The three instrument systems (PTU, PTN, Stand) have caused significant change in original canal curvature(P<0.05). On the other hand, there were no significant differences between systemsin straightening of canal curvature (P>0.05). However, both systems: PTN, Stand were significantly faster than PTU during preparation of curved canals (P<0,001).Conclusion: under the conditions of this study, it can be concluded thatall instruments caused changing in original canal curvature. However, the new generation PTN was faster than old one PTU.
The aim of this study is to investigate the effect of early coronal flaring on changing the working length of curved canals by using NiTi rotary instruments and SS manual instruments. Forty five MB curved canals of upper/lower first and second extracted molars were used.
Aim of Study: The objective of this study was to compare the shaping ability of ProTaper Rotary instruments (Universal, Next), Hand ProTaper instruments and traditional hand instruments in long oval-shaped root canals. Methods and materials: Forty human teeth with long oval-shaped root canals were sectioned at 3 levels in the coronal, middle and apical third. A modified Bramante technique was used and analyzed changes in root canal maximum buccolingual and mesiodistal canal dimensions (ΔBL ,ΔMD) and changes in surface area (ΔA) , under (10X) magnification. Where the sample was divided into four groups each one contains (N=10) teeth and prepares by one of the four instrumentation systems. The morphological changes were analyzed by software Program (Auto Cad 2013).
Aim of Study : The objective of this study was to compare the shaping ability of ProTaper Rotary instruments(Universal,Next) ,Hand ProTaper instruments and traditional hand instruments in long oval-shaped root canals. Methods and materials: Forty human teeth with long oval-shaped root canals were sectioned at one level in the apical third far 3 mm at the apical root . A modified Bramantetechnique was used and analyzed changes in root canal in surface area (ΔA), under (10) magnification. Where the sample was divided into four subgroups each one contains (N=10) teeth and prepares by one of the four instrumentation systems. The morphological changes were analyzed by software Program (Auto Cad 2013).