Do you want to publish a course? Click here

An in vitro comparative study of working length changes in curved canals after coronal flaring by using rotary and hand instrumentation

دراسة مخبرية مقارنة لتغيرات الطول العامل في الأقنية المنحنية بعد التوسيع التاجي باستخدام التحضير الآلي و اليدوي

827   0   40   0 ( 0 )
 Publication date 2016
and research's language is العربية
 Created by Shamra Editor




Ask ChatGPT about the research

The aim of this study is to investigate the effect of early coronal flaring on changing the working length of curved canals by using NiTi rotary instruments and SS manual instruments. Forty five MB curved canals of upper/lower first and second extracted molars were used.


Artificial intelligence review:
Research summary
هدفت هذه الدراسة إلى تقييم تأثير التوسيع التاجي المبكر على تغير الطول العامل للأقنية المنحنية باستخدام أدوات التحضير الآلية (نيكل تيتانيوم) واليدوية (الفولاذ اللاصدئ). شملت الدراسة 45 قناة أنسية دهليزية من أرحاء مقلوعة، مقسمة إلى مجموعتين رئيسيتين: مجموعة الفولاذ اللاصدئ اليدوية (15 عينة) ومجموعة النيكل تيتانيوم الآلية (30 عينة). تم تقسيم المجموعة الآلية بالتساوي بين نظامي Revo-S وMtwo. أظهرت النتائج نقصًا جوهريًا في الطول العامل عند استخدام أدوات الفولاذ اللاصدئ مقارنة بأدوات النيكل تيتانيوم. كما أظهر نظام Revo-S تفوقًا على نظام Mtwo في الحفاظ على الطول العامل بعد التوسيع التاجي، بينما لم يكن هناك فرق جوهري بين النظامين بعد التوسيع النهائي للقناة. توصي الدراسة باستخدام أنظمة التحضير الآلية المصنوعة من النيكل تيتانيوم للحفاظ على الشكل الأصلي للقناة وتقليل التغير في الطول العامل.
Critical review
دراسة نقدية: تعتبر هذه الدراسة ذات أهمية كبيرة في مجال مداواة الأسنان اللبية، حيث تقدم معلومات قيمة حول تأثير أدوات التحضير المختلفة على الطول العامل للأقنية المنحنية. ومع ذلك، يمكن تحسين الدراسة من خلال زيادة حجم العينة لتشمل أنواعًا مختلفة من الأسنان وزيادة تنوع الزوايا الانحنائية للأقنية. كما يمكن تعزيز النتائج من خلال استخدام تقنيات تصوير متقدمة مثل التصوير المقطعي المحوسب ثلاثي الأبعاد لتقييم التغيرات بشكل أدق. بالإضافة إلى ذلك، يمكن أن تكون الدراسة أكثر شمولية إذا تم تضمين تأثير التوسيع التاجي على جوانب أخرى من العلاج اللبّي مثل التلوث البكتيري وسهولة الحشو.
Questions related to the research
  1. ما هو الهدف الرئيسي من هذه الدراسة؟

    الهدف الرئيسي هو تقييم تأثير التوسيع التاجي المبكر على تغير الطول العامل للأقنية المنحنية باستخدام أدوات التحضير الآلية واليدوية.

  2. ما هي الأدوات المستخدمة في هذه الدراسة لتحضير الأقنية؟

    تم استخدام أدوات التحضير اليدوية المصنوعة من الفولاذ اللاصدئ وأدوات التحضير الآلية المصنوعة من النيكل تيتانيوم، بما في ذلك نظامي Revo-S وMtwo.

  3. ما هي النتائج الرئيسية التي توصلت إليها الدراسة؟

    أظهرت الدراسة نقصًا جوهريًا في الطول العامل عند استخدام أدوات الفولاذ اللاصدئ مقارنة بأدوات النيكل تيتانيوم، وأظهر نظام Revo-S تفوقًا على نظام Mtwo في الحفاظ على الطول العامل بعد التوسيع التاجي.

  4. ما هي التوصيات التي قدمتها الدراسة؟

    توصي الدراسة بإجراء قياس الطول العامل بعد التوسيع التاجي للقناة، واستخدام أنظمة التحضير الآلية المصنوعة من النيكل تيتانيوم للحفاظ على الشكل الأصلي للقناة، وإجراء صورة شعاعية لاختبار القمع الرئيسي قبل عملية الحشو القنوي.


References used
CHONG BS, 2010-Harty’s Endodontics in Clinical Practice. Elsevier,6th ed London uk,293
SWARTZ DB, SKIDMORE AE, GRIFFEN JA JR 1983 twenty years of endodontic success and failure, J Endod vol. 9.198– 202p
WEINE FS, KELLY RF, LIO PJ 1975 The effect of preparation procedures on original canal shape and on apical foramen shape, J Endod vol. 1.62-255p
rate research

Read More

Aim: to compare the shaping ability of two rotary systems (Protaper Universal and Protaper Next) and K-file hand instruments in curved root canals of extracted human molars. Materials and methods:Thirty extracted molars with curved canals were cho sen. The curvature of root canals was determined (15-40o) then the sample was randomly divided into three groups: n1=n2=n3=10. Group(1): was prepared using K-file hand instruments (Stand), group(2): prepared by Protaper Universal (PTU), whereas group3: prepared by Protaper Next (PTN).The curvature after preparation and Time preparationwere evaluated. Data were collected and statistical analysis was conducted. Results: The three instrument systems (PTU, PTN, Stand) have caused significant change in original canal curvature(P<0.05). On the other hand, there were no significant differences between systemsin straightening of canal curvature (P>0.05). However, both systems: PTN, Stand were significantly faster than PTU during preparation of curved canals (P<0,001).Conclusion: under the conditions of this study, it can be concluded thatall instruments caused changing in original canal curvature. However, the new generation PTN was faster than old one PTU.
Aim of Study: The objective of this study was to compare the shaping ability of ProTaper Rotary instruments (Universal, Next), Hand ProTaper instruments and traditional hand instruments in long oval-shaped root canals. Methods and materials: Forty human teeth with long oval-shaped root canals were sectioned at 3 levels in the coronal, middle and apical third. A modified Bramante technique was used and analyzed changes in root canal maximum buccolingual and mesiodistal canal dimensions (ΔBL ,ΔMD) and changes in surface area (ΔA) , under (10X) magnification. Where the sample was divided into four groups each one contains (N=10) teeth and prepares by one of the four instrumentation systems. The morphological changes were analyzed by software Program (Auto Cad 2013).
The of this study was to evaluate the bonding strength of a posterior composite restorations when two different types of equipment methods were used for preparation of dentin (Erbium-doped yttrium aluminum garnet laser (Er:YAG ) and diamond burs). This study specimen consisted of Eighty molars, was divided randomly into two main groups (40 molars were prepared with diamond burs, and 40 molars were prepared with laser Er: YAG).
Aim: to compare the shaping ability of NiTi hand instruments with Stainless- steel instruments in preparation of curved root canal in extracted teeth. Materials and Methods: a total of 24 of curved root canal were randomly divided into two groups. O ne group was prepared using stainless steel instruments and the other prepared NiTi instruments. Curvatures pre-and post instrumentation were registered and compared. And straightening of the canals were determined by autocad analysis system. Results: two systems were significantly changed the original canal curvature with no differences between both systems. However, the time required to finish preparation was significantly less with NiTi system. Conclusion: under the conditions of this study, it can be concluded that two hand instrumentation system changed the original canal curvature, but the time consuming to finish the preparation was less with NiTi hand system.
Aim: to compare NiTi hand instruments with Stainless- steel instruments according to separation, deformation and changing of working length during preparation of curved root canal in extracted teeth. Materials and Methods: 24 of curved root canal we re randomly divided into two groups. One group was prepared using stainless steel instruments and the other prepared by NiTi instruments. Separation and deformation of the two hand instrument systems were determined and the changing of working length during preparation were registered and compared. Data were collected and stastical analysis were conducted. Results: Stainless steel system showed more separated and deformed instruments, but there were no significant differences between two systems. Also, change of working length was happened with stainless steel only but without significant differences with NiTi. Conclusion: under the conditions of this study, it can be concluded that two hand instrumentation systems separated and deformed with no differences . However, working length was changed during use stainless steel but without differences between two system.
comments
Fetching comments Fetching comments
Sign in to be able to follow your search criteria
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا