ترغب بنشر مسار تعليمي؟ اضغط هنا

The black-hole binary, V404 Cygni, went into outburst in June 2015, after 26 years of X-ray quiescence. We observed the outburst with the Neil Gehrels Swift observatory. We present optical/UV observations taken with the Swift Ultra-violet Optical Tel escope, and compare them with the X-ray observations obtained with the Swift X-ray Telescope. We find that dust extinction affecting the optical/UV, does not correlate with absorption due to neutral hydrogen that affects the X-ray emission. We suggest there is a small inhomogeneous high density absorber containing a negligible amount of dust, close to the black hole. Overall, temporal variations in the optical/UV appear to trace those in the X-rays. During some epochs we observe an optical time-lag of (15 - 35)s. For both the optical/UV and X-rays, the amplitude of the variations correlates with flux, but this correlation is less significant in the optical/UV. The variability in the light curves may be produced by a complex combination of processes. Some of the X-ray variability may be due to the presence of a local, inhomogeneous and dust-free absorber, while variability visible in both the X-ray and optical/UV may instead be driven by the accretion flow: the X-rays are produced in the inner accretion disc, some of which are reprocessed to the optical/UV; and/or the X-ray and optical/UV emission is produced within the jet.
We present a detailed study of the 2016 eruption of nova V407 Lupi (ASASSN-16kt), including optical, near-infrared, X-ray, and ultraviolet data from SALT, SMARTS, SOAR, Chandra, Swift, and XMM-Newton. Timing analysis of the multiwavelength light-curv es shows that, from 168 days post-eruption and for the duration of the X-ray supersoft source phase, two periods at 565 s and 3.57 h are detected. We suggest that these are the rotational period of the white dwarf and the orbital period of the binary, respectively, and that the system is likely to be an intermediate polar. The optical light-curve decline was very fast ($t_2 leq$ 2.9 d), suggesting that the white dwarf is likely massive ($gtrsim 1.25$ M$_{odot}$). The optical spectra obtained during the X-ray supersoft source phase exhibit narrow, complex, and moving emission lines of He II, also characteristics of magnetic cataclysmic variables. The optical and X-ray data show evidence for accretion resumption while the X-ray supersoft source is still on, possibly extending its duration.
Nova LMC 2009a is confirmed as a Recurrent Nova (RN) from positional coincidence with nova LMC 1971b. The observational data set is one of the most comprehensive for any Galactic or extragalactic RN: optical and near-IR photometry from outburst until over 6 years later; optical spectra for the first 6 months, and Swift satellite Ultraviolet and X-ray observations from 9 days to almost 1 year post-outburst. We find $M_V = -8.4pm0.8_{mathrm{r}}pm0.7_{mathrm{s}}$ and expansion velocities between 1000 and 4000 km s$^{-1}$. Coronal line emission before day 9 indicates shocks in the ejecta. Strengthening of He II $lambda$4686 preceded the emergence of the Super-Soft Source (SSS) in X-rays at $sim63-70$ days, which was initially very variable. Periodic modulations, $P=1.2$ days, most probably orbital in nature, were evident in the UV and optical from day 43. Subsequently, the SSS shows an oscillation with the same period but with a delay of 0.28P. The progenitor system has been identified; the secondary is most likely a sub-giant feeding a luminous accretion disk. Properties of the SSS infer a white dwarf (WD) mass $1.1 mathrm{M}_odot lesssim M_{rm WD} lesssim 1.3 mathrm{M}_odot$. If the accretion occurs at constant rate, $dot{it{M}}_{rm acc} simeq 3.6^{+4.7}_{-2.5} times 10^{-7} mathrm{M}_odot$ yr$^{-1}$ is needed, consistent with nova models for an inter-eruption interval of 38 years, low outburst amplitude, progenitor position in the color-magnitude diagram, and spectral energy distribution at quiescence. We note striking similarities between LMC 2009a and the Galactic nova KT Eri, suggesting that KT Eri is a candidate RN.
PSR J1846-0258 is an object which straddles the boundary between magnetars and rotation powered pulsars. Though behaving for many years as a rotation-powered pulsar, in 2006, it exhibited distinctly magnetar-like behavior - emitting several short har d X-ray bursts, and a flux increase. Here we report on 7 years of post-outburst timing observations of PSR J1846-0258 using the Rossi X-ray Timing Explorer and the Swift X-ray Telescope. We measure the braking index over the post-magnetar outburst period to be $n=2.19pm0.03$. This represents a change of $Delta n=-0.46pm0.03$ or a 14.5$;sigma$ difference from the pre-outburst braking index of $n=2.65pm0.01$, which itself was measured over a span of 6.5 yr. So large and long-lived a change to a pulsar braking index is unprecedented and poses a significant challenge to models of pulsar spin-down.
The X-ray telescope on board the Swift satellite for gamma-ray burst astronomy has been exposed to the radiation of the space environment since launch in November 2004. Radiation causes damage to the detector, with the generation of dark current and charge trapping sites that result in the degradation of the spectral resolution and an increase of the instrumental background. The Swift team has a dedicated calibration program with the goal of recovering a significant proportion of the lost spectroscopic performance. Calibration observations of supernova remnants with strong emission lines are analysed to map the detector charge traps and to derive position-dependent corrections to the measured photon energies. We have achieved a substantial recovery in the XRT resolution by implementing these corrections in an updated version of the Swift XRT gain file and in corresponding improvements to the Swift XRT HEAsoft software. We provide illustrations of the impact of the enhanced energy resolution, and show that we have recovered most of the spectral resolution lost since launch.
505 - O. Godet 2008
(Abbreviated) We show that the XRT spectral response calibration was complicated by various energy offsets in photon counting (PC) and windowed timing (WT) modes related to the way the CCD is operated in orbit (variation in temperature during observa tions, contamination by optical light from the sunlit Earth and increase in charge transfer inefficiency). We describe how these effects can be corrected for in the ground processing software. We show that the low-energy response, the redistribution in spectra of absorbed sources, and the modelling of the line profile have been significantly improved since launch by introducing empirical corrections in our code when it was not possible to use a physical description. We note that the increase in CTI became noticeable in June 2006 (i.e. 14 months after launch), but the evidence of a more serious degradation in spectroscopic performance (line broadening and change in the low-energy response) due to large charge traps (i.e. faults in the Si crystal) became more significant after March 2007. We describe efforts to handle such changes in the spectral response. Finally, we show that the commanded increase in the substrate voltage from 0 to 6V on 2007 August 30 reduced the dark current, enabling the collection of useful science data at higher CCD temperature (up to -50C). We also briefly describe the plan to recalibrate the XRT response files at this new voltage.
The Swift X-ray Telescope focal plane camera is a front-illuminated MOS CCD, providing a spectral response kernel of 135 eV FWHM at 5.9 keV as measured before launch. We describe the CCD calibration program based on celestial and on-board calibration sources, relevant in-flight experiences, and developments in the CCD response model. We illustrate how the revised response model describes the calibration sources well. Comparison of observed spectra with models folded through the instrument response produces negative residuals around and below the Oxygen edge. We discuss several possible causes for such residuals. Traps created by proton damage on the CCD increase the charge transfer inefficiency (CTI) over time. We describe the evolution of the CTI since the launch and its effect on the CCD spectral resolution and the gain.
This paper discusses Swift observations of the gamma-ray burst GRB 050315 (z=1.949) from 80 s to 10 days after the onset of the burst. The X-ray light curve displayed a steep early decay (t^-5) for ~200 s and several breaks. However, both the prompt hard X-ray/gamma-ray emission (observed by the BAT) and the first ~ 300 s of X-ray emission (observed by the XRT) can be explained by exponential decays, with similar decay constants. Extrapolating the BAT light curve into the XRT band suggests the rapidly decaying, early X-ray emission was simply a continuation of the fading prompt emission; this strong similarity between the prompt gamma-ray and early X-ray emission may be related to the simple temporal and spectral character of this X-ray rich GRB. The prompt (BAT) spectrum was a steep down to 15 keV, and appeared to continue through the XRT bandpass, implying a low peak energy, inconsistent with the Amati relation. Following the initial steep decline the X-ray afterglow did not fade for ~1.2*10^4 s, after which time it decayed with a temporal index of alpha ~ 0.7, followed by a second break at ~2.5*10^5 s to a slope of alpha ~ 2. The apparent `plateau in the X-ray light curve, after the early rapid decay, makes this one of the most extreme examples of the steep-flat-steep X-ray light curves revealed by Swift. If the second afterglow break is identified with a jet break then the jet opening angle was theta_0 ~ 5 deg, and implying E_gamma > 10^50 erg.
The Swift X-ray Telescope (XRT) focal plane camera is a front-illuminated MOS CCD, providing a spectral response kernel of 144 eV FWHM at 6.5 keV. We describe the CCD calibration program based on celestial and on-board calibration sources, relevant i n-flight experiences, and developments in the CCD response model. We illustrate how the revised response model describes the calibration sources well. Loss of temperature control motivated a laboratory program to re-optimize the CCD substrate voltage, we describe the small changes in the CCD response that would result from use of a substrate voltage of 6V.
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا