Studying the Influence of Optical Coefficients on Fluorescence Signal

دراسة تأثير العوامل الضوئية على إشارة طيف التألق

981   0   61   0 ( 0 )
 Publication date 2017
and research's language is العربية
 Created by Shamra Editor




Ask ChatGPT about the research

Fluorescence spectroscopy has long been one of the most useful bio-physical techniques available to scientists studying the structure and function of biological tissues due to high sensitivity of fluorescence signal to variations of optical properties of tissues as a result of structural variations.


Artificial intelligence review:
Research summary
تتناول هذه الدراسة تأثير العوامل الضوئية على إشارة طيف التألق باستخدام مركب بروتوبورفيرين IX (PpIX) كمادة قابلة للتألق. يتم بناء نماذج ضوئية فيزيائية لمحاكاة الأنسجة الحية بخصائص ضوئية متنوعة، ويتم توصيف هذه المواد المستخدمة في بناء النماذج الضوئية. تهدف الدراسة إلى فهم العلاقة بين شدة إشارة طيف التألق والعوامل الضوئية مثل عامل الامتصاص وعامل التبعثر وتركيز المادة المتألقة والألبيدو. يتم استخدام الحبر الهندي الأسود لمحاكاة الامتصاص والمستحلب الشحمي لمحاكاة التبعثر، بينما يتم استخدام ملح صوديوم البروتوبورفيرين لمحاكاة التألق. يتم بناء مطيافية نفاذ الحزمة المتوازية ومطيافية التألق لتسجيل الأطياف ودراسة العلاقات الكمية بين شدة إشارة طيف التألق والعوامل الضوئية. تشير النتائج إلى أن شدة إشارة طيف التألق تزداد مع زيادة عامل التبعثر وتركيز المادة المتألقة، بينما تتناقص مع زيادة عامل الامتصاص. كما تم التوصل إلى علاقات خطية بين العوامل الضوئية وتركيز المواد المستخدمة.
Critical review
دراسة نقدية: تعتبر هذه الدراسة خطوة مهمة في مجال فهم تأثير العوامل الضوئية على إشارات طيف التألق، ولكن هناك بعض النقاط التي يمكن تحسينها. أولاً، كان من الممكن توسيع نطاق الدراسة لتشمل مواد أخرى قابلة للتألق غير البروتوبورفيرين IX، مما قد يوفر نتائج أكثر شمولية. ثانياً، لم يتم التطرق بشكل كافٍ إلى تأثير العوامل البيئية مثل درجة الحرارة والرطوبة على النتائج، وهو ما يمكن أن يؤثر على دقة القياسات. ثالثاً، كان من الممكن استخدام تقنيات تحليلية أكثر تقدماً لتحليل البيانات، مما قد يوفر دقة أعلى في النتائج المستخلصة. وأخيراً، كان من الأفضل تضمين دراسة مقارنة مع نتائج دراسات سابقة لتأكيد النتائج وتوضيح مدى توافقها مع الأبحاث الأخرى في هذا المجال.
Questions related to the research
  1. ما هو الهدف الرئيسي من هذه الدراسة؟

    الهدف الرئيسي من الدراسة هو فهم العلاقة بين شدة إشارة طيف التألق والعوامل الضوئية مثل عامل الامتصاص وعامل التبعثر وتركيز المادة المتألقة والألبيدو.

  2. ما هي المواد المستخدمة لمحاكاة الامتصاص والتبعثر في النماذج الضوئية؟

    تم استخدام الحبر الهندي الأسود لمحاكاة الامتصاص والمستحلب الشحمي لمحاكاة التبعثر.

  3. ما هي العلاقة بين شدة إشارة طيف التألق وعامل التبعثر؟

    تزداد شدة إشارة طيف التألق مع زيادة عامل التبعثر.

  4. كيف تؤثر زيادة تركيز المادة المتألقة على شدة إشارة طيف التألق؟

    تزداد شدة إشارة طيف التألق مع زيادة تركيز المادة المتألقة.


References used
Rupananda Mallia, J., Subhash, N., Shiny, S.T. Anitha, M., Paul, S., and Jayaprakash, M., 2008 - In vivo 5-ALA induced PpIX fluorescence kinetics of different anatomical sites of oral cavity: An application in oral cancer detection, Laser in Surgery and Medicine
Tyrrell, J., Campbell, S., and Curnow, A., 2010 - Validation of a non-invasive fluorescence imaging system to monitor dermatological PDT, . Photodiagnosis and Photodynamic Therapy
Collaud, S., Juzeniene, A., Moan, J., 2004 - On the Selectivity of 5- Aminolevulinic Acid-Induced Protoporphyrin IX Formation, Current Medicinal Chemistry - Anti-Cancer Agents
rate research

Read More

The chromatic dispersion of fiber is a major factor causing distortion of the light signals, and if not being addressed using accurate compensators it will lead to a significant deterioration in the performance of optical system. The value of chr omatic dispersion is not fixed along the fiber, and this necessitates the use of tunable dispersion compensators which need information about the value of dispersion which is done by dispersion monitoring. This research is Interested in analyzing chromatic dispersion technique based on the measuring of clock tone power of transmitted data and which is commensurate with the dispersion of the fiber. We found the relationship between signal frequency with range and accuracy of measurement. Also, the advantage of this technique to provide feedback signal to tunable dispersion compensator. The results show the extent of the improvement made in network performance. VPItransmissionmaker program was used to simulate the technique proposed.
The aim of this paper is to determine the best optical-probe geometry that would help to detect neoplastic lesions in oral epithelial tissue. Two Geometrical configurations are investigated. The first one implements different distances between the illumination and collection fibers, and the second one implements different fiber diameters. Both of these geometries are evaluated for their collection efficiency and depth resolution. The effect of numerical aperture (NA) and tissue optical properties on the fluorescence signal are also studied. Optical properties of dysplastic tongue epithelial multi-layered tissue were used as an input for Monte Carlo simulation. The results show that the sensitivity to superficial layers can be achieved using small fiber diameters. On the contrary, the sensitivity to deeper layers can be achieved using larger distances between illumination and collection fibers.
this research studies 2x2 MIMO LTE signal transmission from the main tower eNB and the relay node RN over single mode fiber using ROF technology and take advantage of the WDM technology, the results show the ability of ROF to accommodate MIMO com munication with high efficiency. The network has been simulated and analyzed using Optisystem program, and the results were more than promising.
Monodispersed CdSe nanoparticles with sufficient luminescence intensity have been prepared by chemical method in solution phase, and in two forms: CdSe as a core covered by Olic acide as an organic capping agent, while the second form is CdSe as a co re covered by a layer of CdS (CdSe/CdS core shell). The nanodots size obtained directly from high resolution transmission electron microscopy (TEM) and absorption peaks using Paul Mulvaneys formula are in good agreement. The optical properties and the luminescence intensity as a function of CdSe concentration and the type of solvent have been investigated. The intensity of photoluminescence peak decreases and the peak shifts toward the blue energy side as the concentration reduced
In this research we have prepared thin films from poly vinyl chloride (PVC) by spin coating technique in three velocities (1000,2000,3000)RPM on glass substrate (Micro scope cover glass), at room temperature. The absorbance A, and transmittance T f or the films were studied in the visible and ultra-violet region (UV-VIS). In addition,we have calculated the absorbance coefficient α, skin depth δ, refractive index no, dielectric constant ε (the real part and the imaginary part), also we have calculated the energy band gap of allowed and forbidden direct transitions. The films showed high transmittance (80-90)%, in the infrared region as a function of the spinning velocity and took the maximum value 80% for the velocity 1000RPM, and 90% for the velocity 3000RPM, and the refractive index was decreased with the velocity increase, we found it between3.67 and 4.56 for the velocities 3000RPM and 1000RPM respectively. Whereas the skin depth δ decreased with the increasing of velocity, the minimum value was 0.0000531cm for the velocity 3000RPM and the maximum value was almost 0.00023cm for the velocity 1000RPM.
comments
Fetching comments Fetching comments
Sign in to be able to follow your search criteria
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا