The thermal analysis of radiant heating by the final elements method to choose suitable control for central heating systems in host buildings

التحليل الحراري لمشعات التدفئة باستخدام طريقة العناصر المنتهية FEM لإختيار نظام التحكم المناسب لأنظمة التدفئة المركزيــة للمنشآت السكنية

1419   1   80   0 ( 0 )
 Publication date 2015
and research's language is العربية
 Created by Shamra Editor




Ask ChatGPT about the research

This research performs thermal analysis of the central heating's radiator by the final elements method manner using Cosmos/m2.6, Where it was designing a three dimensional model of the radiator with engineering specifications that mimic one of the used radiators .Then apply a convection simulates the role of the mediator heating used and ambient temperature for concluding the mathematical behavior of thermal gradient within the radiator. Research proposing a control system depends on adjusting the intermediary of heating inside the radiator, through the installation of flow control valve which works by D.C motors at the entrance to each radiant. The research shows the inability of depending on controlling system which uses the PI controller in building a suitable control system, Because the difficulty of receiving signals from analog temperature sensor that reflect the constant readings of room temperature which makes the response of control valve for signals slow, Thus makes the use of PI unhelpful of the economic and technical side.


Artificial intelligence review:
Research summary
يتناول البحث التحليل الحراري لمشعات التدفئة المركزية باستخدام طريقة العناصر المنتهية (FEM) وبرنامج Cosmos/M2.6. تم بناء نموذج ثلاثي الأبعاد لمشع حراري بمواصفات هندسية تحاكي المشعات المستخدمة، وتطبيق حمل حراري لمحاكاة وسيط التدفئة ودرجة حرارة الوسط المحيط. يهدف البحث إلى اختيار نظام التحكم المناسب لأنظمة التدفئة المركزية في المنشآت السكنية. يقترح البحث نظام تحكم يعتمد على ضبط وسيط التدفئة الداخل إلى المشع باستخدام صمام تحكم بالتدفق يعمل بمحرك تيار مستمر. أظهرت النتائج أن استخدام المتحكم التناسبي التكاملي (PI) غير مجدي بسبب بطء استجابة صمام التحكم، مما يجعل من استخدامه غير اقتصادي. بدلاً من ذلك، يقترح البحث استخدام المتحكم الرقمي المباشر (DDC) مع صمامات كهربائية تعمل بنظام (ON/OFF) لتحقيق توفير في استهلاك الوقود وتحسين أداء النظام.
Critical review
دراسة نقدية: بالرغم من أن البحث يقدم حلاً تقنياً مهماً لتحسين كفاءة أنظمة التدفئة المركزية، إلا أنه يفتقر إلى دراسة تفصيلية لتكلفة التنفيذ الفعلية للنظام المقترح مقارنة بالنظام التقليدي. كما أن البحث لم يتناول بشكل كافٍ تأثير التغيرات المناخية الموسمية على أداء النظام المقترح. بالإضافة إلى ذلك، قد يكون من المفيد تضمين دراسة مقارنة بين أنظمة التحكم المختلفة من حيث الأداء والكفاءة الاقتصادية في بيئات مختلفة.
Questions related to the research
  1. ما هو الهدف الرئيسي من البحث؟

    الهدف الرئيسي هو اختيار نظام التحكم المناسب لأنظمة التدفئة المركزية في المنشآت السكنية باستخدام التحليل الحراري لمشعات التدفئة بطريقة العناصر المنتهية.

  2. لماذا يعتبر استخدام المتحكم التناسبي التكاملي (PI) غير مجدي في هذا البحث؟

    لأن استجابة صمام التحكم لإشارات المتحكم PI تكون بطيئة، مما يجعله غير مجدي من الناحية الاقتصادية والفنية.

  3. ما هو النظام البديل الذي يقترحه البحث بدلاً من المتحكم التناسبي التكاملي (PI)؟

    يقترح البحث استخدام المتحكم الرقمي المباشر (DDC) مع صمامات كهربائية تعمل بنظام (ON/OFF).

  4. ما هي الفائدة الاقتصادية المتوقعة من النظام المقترح في البحث؟

    النظام المقترح يهدف إلى تقليل استهلاك الوقود وتحسين أداء نظام التدفئة، مما يؤدي إلى توفير في نفقات التشغيل والصيانة.


References used
LEVENHAGEN,J.I.HAVAC. Controlsystemdesigndiagrams. s.mcgrawhillL, UnitedStateofAmirica,1999
GOWRI,K. Control of boiler operation using PLC-SCADA. proceedings of the international multiconference of engineers and computer scientists.vol.2,2008,19-21 march
RUEY,G.OptimalPID speed control of brushless dc motors using LQRapproach.ieee international conference on systems, man and cybernetics,2004,473- 478
rate research

Read More

The present paper aims to use the thermal energy source for heating and water heating, by mechanical method, and using rotary thermal generator doesn't produce environmental harmful gases. The thermal rotary has high specifications: easy investmen t and low economic costs. In our present work, we designed a special plan for placing the thermal rotary in the housethermal heating system, for hot water production, for kitchens, washing and other alimentary manufactures. However, the plans explain using rotary thermal generator which could save in most traditional heating machines and water heating especially boiler, burner and flue that produces gases due to fuel combustion that is polluted environment, so that they are economic and environmental friend.
وصف عام لمشروع التدفئة والتكيف: هو عبارة عن فندق في السويداء يتألف من أربعة طوابق وقبو.  الطابق الأرضي: هو عبارة عن غرف استقبال الزبائن وبهو للفندق ومطعم وتراسات صيفية.  الطابق الأول: هو طابق الميزانين ويحوي على مكتب المدير ومكاتب المضيفين و يوجد فيه صالة.  الطابق الثاني: هو عبرة عن طابق متكرر ويحوي غرف النزلاء.  الطابق الثالث: هو تكرار الطابق الثاني.  القبو: 1- يحتوي على غرف المستودعات ومطبخ وصالة انترنت وبلياردو وغرفة تحوي كامل تجهيزات التدفئة. 2- وسنقوم بالمشروع بتدفئة جزء من القبو والطابق الأرضي والميزانين والمتكرر بالمشعات. 3- وسنقوم بتكييف صالة البلياردو وصالة الأنترنت والبار والصالة العلوية والمطعم بوحدات المعالجة المركزية.
The basic idea of the research is to deal with the problems facing floor solar heating systems (high Constituent cost, huge size of the storage tank, difficulty of implementation ...)in addition to fuel consumption. Despite the use of solar energy for the purpose of heating, that does not mean full dispensing for heaters assistance in order to increase the temperature of water in the days which the intensity of solar radiation is low.
The building sector is considered one of the leading sectors in energy-consumption. In addition to lighting, heating and cooling systems have become important consumers in all buildings (both residential, administrative, and service both private and public) ensuring a comfortable environment for staff and workers and improving productivity at the lowest possible cost. This research aims to study the control quantities of fresh and exhausted air in large halls and auditoriums, where the occupancy level changes. This is done by adjusting the amount of fresh and exhausted air according to the occupancy via CO2 sensors, which measure the ratio of CO2 in the targeted places, controlling the volume of fresh and exhausted air according to the number of available people. A case study was done to use control systems; final results and conclusions have been illustrated.
In this paper, the modeling methods of tunneling and the surface subsidence induced by that have been studied by using two-dimensional numerical analysis according to the FEM method, assuming the green field condition، which means that there is no load on the soil surface above the tunnel. A FE study was conducted in which an elasto-plastic constitutive model was adopted to model the soil behavior (HS, HSsmall). This article includes a comparison between the results of numerical analysis and field measurements to executed projects، and a suggested method for modeling tunnel excavation and surface subsidence induced by that.
comments
Fetching comments Fetching comments
Sign in to be able to follow your search criteria
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا