A laboratory Study to compare modified replica technique and replica technique used to measure the marginal fit of zirconium posterior bridges CAD\CAM

دراسة مخبرية لمقارنة تقنيّتي النسخ المضاعف و النسخ المضاعف المطورة المستخدمة لقياس الإنطباق الحفافيّ للجسور الزيركونيّة الخلفية CAD\CAM

1125   0   11   0 ( 0 )
 Publication date 2014
  fields Dentistry
and research's language is العربية
 Created by Shamra Editor




Ask ChatGPT about the research

Replica technique remain most commonly used technique for measuring the marginal fit in the medical literature, the silicone rubber addition is considered most accurate and least changing dimensions. Aim of study to compare the accuracy and simplicity of traditional replica technique and modified replica technique to measure marginal fit of zirconium posterior bridges manufactured by CAD\CAM. After removal of first lower molar from TYPODENT (Frasco, Tettnang, Germany), the second lower molar and premolar neighboring were prepared commensurate with full ceramic restoration. Final impression of this bridge was taken by silicone rubber addition (Zhermack Elite HD+) with the aid of custom tray. The impression was condensed with amalgam to make the main metal cast. Fifteen custom acrylic resin trays were used for fabricate fifteen impressions of main metal cast that were used for fabricate 15 zirconium bridges by CAD\CAM technique According to the manufacturer's instructions. Tow rubber thicknesses were taken for the marginal fit of each bridge over its cast gypsum by used light silicone rubber addition. Then the first rubber thickness was treated by developed replica technique to form the Group (A) of the study and the second rubber thickness was treated by replica technique to form the group (B) of the study. Depending on T-test, no significant difference between two techniques was detected. We conclude that developed replica technique reliable technique to study and measure the marginal gap of bridge and crown, and it is statistically more accurate than the traditional technique.


Artificial intelligence review:
Research summary
تتناول هذه الدراسة المخبرية مقارنة بين تقنيتي النسخ المضاعف والنسخ المضاعف المطورة لقياس الانطباق الحفافي للجسور الزيركونية الخلفية المصنعة بتقنية CAD/CAM. بعد إزالة الرحى الأولى السفلية اليمنى من نموذج typodont، تم تحضير الضاحك الثاني والرحى الثانية المجاورتين بما يتناسب مع الترميمات الخزفية الكاملة. تم أخذ طبعة باستخدام المطاط السيليكوني الإضافي وصنع المثال الرئيسي المعدني. تم استخدام 15 طابع إكريلي لعمل 15 طبعة للمثال المعدني الرئيسي، وصنع 15 جسر زيركوني بتقنية CAD/CAM. تم قياس الانطباق الحفافي باستخدام المطاط السيليكوني الإضافي الرخو، وتمت معالجة الرقاقات بتقنيتي النسخ المضاعف والنسخ المضاعف المطورة. أظهرت النتائج عدم وجود فروق دالة إحصائياً بين التقنيتين في متوسط مقدار الفجوة الحفافية، مما يشير إلى أن تقنية النسخ المضاعف المطورة موثوقة وأكثر دقة من التقنية التقليدية.
Critical review
دراسة نقدية: على الرغم من أن الدراسة تقدم مقارنة شاملة بين تقنيتي النسخ المضاعف والنسخ المضاعف المطورة، إلا أن هناك بعض النقاط التي يمكن تحسينها. أولاً، كان من الممكن تضمين عدد أكبر من العينات لزيادة قوة النتائج الإحصائية. ثانياً، لم يتم التطرق إلى تأثير العوامل البيئية مثل درجة الحرارة والرطوبة على دقة القياسات. ثالثاً، كان من الممكن تقديم تحليل أعمق للعوامل التي قد تؤثر على دقة التقنية المطورة مقارنة بالتقنية التقليدية. وأخيراً، كان من المفيد تضمين مقارنة مع تقنيات أخرى لقياس الانطباق الحفافي لتعزيز مصداقية النتائج.
Questions related to the research
  1. ما هي التقنية الأكثر دقة في قياس الانطباق الحفافي للجسور الزيركونية الخلفية؟

    تقنية النسخ المضاعف المطورة أظهرت دقة أعلى مقارنة بتقنية النسخ المضاعف التقليدية.

  2. ما هو الهدف الرئيسي من هذه الدراسة؟

    الهدف الرئيسي هو مقارنة دقة وسهولة قياس الانطباق الحفافي للجسور الزيركونية الخلفية بين تقنيتي النسخ المضاعف والنسخ المضاعف المطورة.

  3. ما هي المادة الطابعة المستخدمة في هذه الدراسة؟

    المطاط السيليكوني الإضافي (Zhermack Elite HD+).

  4. هل أظهرت النتائج فروق دالة إحصائياً بين التقنيتين؟

    لا، لم تظهر النتائج فروق دالة إحصائياً بين التقنيتين في متوسط مقدار الفجوة الحفافية.


References used
BEHR, M. ROSENTRITT, M. LATZEL, D. KREISLER, T; Comparison of three types of fiber-reinforced composite molar crowns on their fracture resistance and marginal adaptation. Journal of Dentistry. 2001; 29 (3), 187-196
BINDLE, A; MORMANN, WH. Marginal and internal fit of allceramic CAD/CAD crown-copings on chamfer preparations. J Oral Rehabil. 2005; 32: 441-447
BLACKMAN, R. BAES, R. BARGHI, N; Marginal accuracy and geometry of cast titanium copings. J Prosthet Dent.1992; 67: 435-440
[Boksman, L. Cowie, R; Making polyvinyl impression: Success lies in the details. Available from >www.thejobcure.com<. 2007; [Jul\Aug
Boksman, L; Point of care how do I minimize the amount of occlusal adjustment necessary for a crown. JCDA. 2005; 71:49-95
rate research

Read More

Recent development in dental materials had led to the fabrication of metal free fixed prosthodontics to improve the mechanical and aesthetic properties to restore posterior teeth depending on many techniques, therefore came the propose of this stud y to compare the marginal fit of Zirconia bridges made by CAD/CAM and Slip-Cast techniques. 30 Bridges were fabricated to restore missing first lower molar, they were divided into two groups (15 CAD\CAM, 15 Slip-Cast). The marginal fit was evaluated by measuring the thickness of light body silicone that made using Replica technique. Depending on T-test, the mean marginal discrepancy for CAD/CAM groups was 13.92μ and 11.30μ for Slip-Cast techniques. Therefore, it was concluded that the marginal fit of Slip-Cast techniques was significantly better than CAD/CAM techniques.
Background& Objective: This study was carried out to test fracture resistance of crowns with Zirconia core made by CAD/CAM of two thicknesses, and test the influence of decreasing the core thickness on its fracture resistance, and study the patterns of failure.
The copying mechanism has had considerable success in abstractive summarization, facilitating models to directly copy words from the input text to the output summary. Existing works mostly employ encoder-decoder attention, which applies copying at ea ch time step independently of the former ones. However, this may sometimes lead to incomplete copying. In this paper, we propose a novel copying scheme named Correlational Copying Network (CoCoNet) that enhances the standard copying mechanism by keeping track of the copying history. It thereby takes advantage of prior copying distributions and, at each time step, explicitly encourages the model to copy the input word that is relevant to the previously copied one. In addition, we strengthen CoCoNet through pre-training with suitable corpora that simulate the copying behaviors. Experimental results show that CoCoNet can copy more accurately and achieves new state-of-the-art performances on summarization benchmarks, including CNN/DailyMail for news summarization and SAMSum for dialogue summarization. The code and checkpoint will be publicly available.
The elapsed time is considered as an essential factor when some procedures are required on resin composite restorations like repairing, etc.., and the question is whether this factor is going to effect on using silorane resin composite. Twenty sil orane based resin composite blocks were prepared (8×8×4)mm, randomly assigned into two groups: the first group 10 blocks, half of each resin block was removed by diamond burs after thermocycles, the second group 10 blocks also half of each resin block was removed by diamond burs after fabrication. All Interfacial surfaces were conditioned by (Cojet™, 3M ESPE). Blocks were restored with silorane resin composite and subjected to thermocycles. Microleakage observed under a stereomicroscope after blocks were immersed in 0.5% basic fuchsin solution for 10 s, and transversely sectioned. Mann-Whitney U test found no statistically significant differences in microleakage between two groups either with fresh silorane resin composite group or aged silorane resin composite group.
The results discussion confirms that we have to treat all grinded porcelain surfaces and not to leave them rough if we could not send them back to the lap. for reglazzing. this study shows the possibility of using shoufu kit to polish the grinded porcelain in state of re-glazing it.