ﻻ يوجد ملخص باللغة العربية
We test the accuracy of ALMA flux density calibration by comparing ALMA flux density measurements of extragalactic sources to measurements made by the Planck mission; Planck is absolutely calibrated to sub-percent precision using the dipole signal induced by the satellites orbit around the solar system barycenter. Planck observations ended before ALMA began systematic observations, however, and many of the sources are variable, so we employ measurements by the Atacama Cosmology Telescope (ACT) to bridge the two epochs. We compare ACT observations at 93 and $sim$145 GHz to Planck measurements at 100 and 143 GHz and to ALMA measurements made at 91.5 and 103.5 GHz in Band 3. For both comparisons, flux density measurements were corrected to account for the small differences in frequency using the best available spectral index for each source. We find the ALMA flux density scale (based on observations of Uranus) is consistent with Planck. All methods used to make the comparison are consistent with ALMA flux densities in Band 3 averaging 0.99 times those measured by Planck. One specific test gives ALMA/Planck = $0.996 pm 0.024.$ We also test the absolute calibration of both ACT at 93 and $sim$145 GHz and the South Pole Telescope (SPT) at 97.43, 152.9 and 215.8 GHz, again with reference to Planck measurements at 100, 143 and 217 GHz, as well as the internal consistency of measurements of compact sources made by all three instruments.
ALMA 870$mu$m continuum imaging has uncovered a population of blends of multiple dusty star-forming galaxies (DSFGs) in sources originally detected with the Herschel Space Observatory. However, their pairwise separations are much smaller that what is
We present a detailed description of the special procedures for calibration and quality assurance of Atacama Large Millimeter/submillimeter Array (ALMA) observations in Very Long Baseline Interferometry (VLBI) mode. These procedures are required to t
The pressure of hot gas in groups and clusters of galaxies is a key physical quantity, which is directly linked to the total mass of the halo and several other thermodynamical properties. In the wake of previous observational works on the hot gas pre
We discuss the methods employed to photometrically calibrate the data acquired by the Low Frequency Instrument on Planck. Our calibration is based on a combination of the Orbital Dipole plus the Solar Dipole, caused respectively by the motion of the
We present a description of the pipeline used to calibrate the Planck Low Frequency Instrument (LFI) timelines into thermodynamic temperatures for the Planck 2015 data release, covering four years of uninterrupted operations. As in the 2013 data rele