Field emission is one of the factors that can limit the performance of superconducting radio frequency cavities. In order to reduce possible field emission in LCLS-II (Linac Coherent Light Source II), we are developing plasma processing for 1.3 GHz 9-cell cavities. Plasma processing can be applied in situ in the cryomodule to mitigate field emission related to hydrocarbon contamination present on the cavity surface. In this paper, plasma cleaning was applied to single cell and 9-cell cavities, both clean and contaminated; the cavities were cold tested before and after plasma processing in order to compare their performance. It was proved that plasma cleaning does not negatively affect the nitrogen doping surface treatment; on the contrary, it preserves the high quality factor and quench field. Plasma processing was also applied to cavities with natural field emission or artificially contaminated. It was found that this technique successfully removes carbon-based contamination from the cavity iris and that it is able to remove field emission in a naturally field emitting cavity. Vacuum failure experiments were simulated on four cavities, and in some cases plasma processing was able to achieve an increase in performance.



قيم البحث

اقرأ أيضاً

Superconducting Radio Frequency (SRF) cavities performance preservation is crucial, from vertical test to accelerator operation. Field Emission (FE) is still one of the performance limiting factors to overcome and plasma cleaning has been proven succ essful by the Spallation Neutron Source (SNS), in cleaning field emitters and increasing the work function of Nb. A collaboration has been established between Fermi National Accelerator Laboratory (FNAL), SLAC National Accelerator Laboratory and Oak Ridge National Laboratory (ORNL) with the purpose of applying plasma processing to the Linac Coherent Light Source-II (LCLS-II) cavities, in order to minimize and overcome field emission without affecting the high Q of nitrogen-doped cavities. The cleaning for LCLS-II will follow the same plasma composition adopted at SNS, which allows in-situ processing of cavities installed in cryomodules from hydrocarbon contaminants. A novel method for plasma ignition has been developed at FNAL: a plasma glow discharge is ignited using high order modes to overcome limitations imposed by the fundamental power coupler, allowing in-situ cleaning for cavities in cryomodule. The plasma can be easily ignited and tuned in each of the cavity cells using low RF power. A method for plasma detection has been developed as well, which allows the detection of the plasma location in the cavity without the need of cameras at both cavity ends. The presented method can be applied to other multi-cell cavity designs, even for accelerators where the coupling for the fundamental modes at room temperature is very weak.
In this study, we present new insights on the origin of the high-field Q-slope in superconducting radio-frequency cavities. Consequent hydrofluoric acid rinses are used to probe the radio-frequency performance as a function of the material removal of two superconducting bulk niobium cavities prepared with low temperature nitrogen infusion. The study reveals that nitrogen infusion affects only the first few tens of nanometers below the native oxide layer. The typical high-field Q-slope behavior of electropolished cavities is indeed completely recovered after a dozen hydrofluoric acid rinses. The reappearance of the high-field Q-slope as a function of material removal was modeled by means of Londons local description of screening currents in the superconductor, returning good fitting of the experimental data and suggesting that interstitial impurities layers with diffusion length of the order to tens of nanometers can mitigate high-field Q-slope.
202 - K. Bane 2014
The superconducting cavities in the continuous wave (CW) linacs of LCLS-II are designed to operate at 2 K, where cooling costs are very expensive. One source of heat is presented by the higher order mode (HOM) power deposited by the beam. Due to the very short bunch length--especially in L3 the final linac--the LCLS-II beam spectrum extends into the terahertz range. Ceramic absorbers, at 70 K and located between cryomodules, are meant to absorb much of this power. In this report we perform two kinds of calculations to estimate the effectiveness of the absorbers and the amount of beam power that needs to be removed at 2 K.
184 - K. Bane , T. Raubenheimer 2014
In LCLS-II, after acceleration and compression and just before entering the undulator, the beam passes through 2.5 km of 24.5 mm (radius) stainless steel pipe. The bunch that passes through the pipe is extremely short---with an rms of 8 um for the no minal 100 pC case. Thus, even though the pipe has a large aperture, the wake that applies is the {it short-range} resistive wall wakefield. The bunch distribution is approximately uniform, and therefore the wake induced voltage is characterized by a rather linear voltage chirp. It turns out that the wake supplies needed dechirping to the LCLS-II beam before it enters the undulator. In this note we calculate the wake, discuss the confidence in the calculation, and investigate how to improve the induced chirp linearity and/or strength. Finally, we also study the strength and effects of the transverse (dipole) resistive wall wakefield.
This paper describes the concept for the DArk Sector Experiments at LCLS-II (DASEL) facility which provides a near-CW beam of multi-GeV electrons to the SLAC End Station A for experiments in particle physics. The low-current multi-GeV electron beam i s produced parasitically by the superconducting RF linac for the LCLS-II X-ray Free Electron Laser, which is under construction at SLAC. DASEL is designed to host experiments to detect light dark matter such as the Light Dark Matter eXperiment (LDMX) but can be configured to support a wide range of other experiments requiring current ranging from pico-amps to micro-amps.