Superconducting Radio Frequency (SRF) cavities performance preservation is crucial, from vertical test to accelerator operation. Field Emission (FE) is still one of the performance limiting factors to overcome and plasma cleaning has been proven successful by the Spallation Neutron Source (SNS), in cleaning field emitters and increasing the work function of Nb. A collaboration has been established between Fermi National Accelerator Laboratory (FNAL), SLAC National Accelerator Laboratory and Oak Ridge National Laboratory (ORNL) with the purpose of applying plasma processing to the Linac Coherent Light Source-II (LCLS-II) cavities, in order to minimize and overcome field emission without affecting the high Q of nitrogen-doped cavities. The cleaning for LCLS-II will follow the same plasma composition adopted at SNS, which allows in-situ processing of cavities installed in cryomodules from hydrocarbon contaminants. A novel method for plasma ignition has been developed at FNAL: a plasma glow discharge is ignited using high order modes to overcome limitations imposed by the fundamental power coupler, allowing in-situ cleaning for cavities in cryomodule. The plasma can be easily ignited and tuned in each of the cavity cells using low RF power. A method for plasma detection has been developed as well, which allows the detection of the plasma location in the cavity without the need of cameras at both cavity ends. The presented method can be applied to other multi-cell cavity designs, even for accelerators where the coupling for the fundamental modes at room temperature is very weak.

قيم البحث

اقرأ أيضاً

The CW RF test of 1.3 GHz 9-cell cavity in liquid helium bath at 2 K is a very important key point in the cavity procurement. Some problems can be found through the test, according which to optimized and improve the process of cavity. Recently, Mediu m temperature (mid-T) furnace bake of 1.3 GHz 9-cell cavities have been carried out at IHEP. Through the proceed of mid-T bake, the quality factor of cavity has been greatly improved. While the excitation of the parasitic modes in the high Q cavities CW cold test has been encountered, which implies an error source for the cavity gradient and quality factor determination. In order to ensure the testing accuracy of superconducting cavity, we have improved the testing system. Finally, the parasitic mode is completely suppressed and the CW RF cold test of high Q cavity is guaranteed.
Superconducting linacs are capable of producing intense, stable, high-quality electron beams that have found widespread applications in science and industry. The 9-cell 1.3-GHz superconducting standing-wave accelerating RF cavity originally developed for $e^+/e^-$ linear-collider applications [B. Aunes, {em et al.} Phys. Rev. ST Accel. Beams {bf 3}, 092001 (2000)] has been broadly employed in various superconducting-linac designs. In this paper we discuss the transfer matrix of such a cavity and present its measurement performed at the Fermilab Accelerator Science and Technology (FAST) facility. The experimental results are found to be in agreement with analytical calculations and numerical simulations.
187 - Bianca Giaccone 2020
Field emission is one of the factors that can limit the performance of superconducting radio frequency cavities. In order to reduce possible field emission in LCLS-II (Linac Coherent Light Source II), we are developing plasma processing for 1.3 GHz 9 -cell cavities. Plasma processing can be applied in situ in the cryomodule to mitigate field emission related to hydrocarbon contamination present on the cavity surface. In this paper, plasma cleaning was applied to single cell and 9-cell cavities, both clean and contaminated; the cavities were cold tested before and after plasma processing in order to compare their performance. It was proved that plasma cleaning does not negatively affect the nitrogen doping surface treatment; on the contrary, it preserves the high quality factor and quench field. Plasma processing was also applied to cavities with natural field emission or artificially contaminated. It was found that this technique successfully removes carbon-based contamination from the cavity iris and that it is able to remove field emission in a naturally field emitting cavity. Vacuum failure experiments were simulated on four cavities, and in some cases plasma processing was able to achieve an increase in performance.
The FLASHForward experimental facility is a high-performance test-bed for precision plasma-wakefield research, aiming to accelerate high-quality electron beams to GeV-levels in a few centimetres of ionised gas. The plasma is created by ionising gas i n a gas cell either by a high-voltage discharge or a high-intensity laser pulse. The electrons to be accelerated will either be injected internally from the plasma background or externally from the FLASH superconducting RF front end. In both cases the wakefield will be driven by electron beams provided by the FLASH gun and linac modules operating with a 10 Hz macro-pulse structure, generating 1.25 GeV, 1 nC electron bunches at up to 3 MHz micro-pulse repetition rates. At full capacity, this FLASH bunch-train structure corresponds to 30 kW of average power, orders of magnitude higher than drivers available to other state-of-the-art LWFA and PWFA experiments. This high-power functionality means FLASHForward is the only plasma-wakefield facility in the world with the immediate capability to develop, explore, and benchmark high-average-power plasma-wakefield research essential for next-generation facilities. The operational parameters and technical highlights of the experiment are discussed, as well as the scientific goals and high-average-power outlook.
Particle in Cell (PIC) simulations are a widely used tool for the investigation of both laser- and beam-driven plasma acceleration. It is a known issue that the beam quality can be artificially degraded by numerical Cherenkov radiation (NCR) resultin g primarily from an incorrectly modeled dispersion relation. Pseudo-spectral solvers featuring infinite order stencils can strongly reduce NCR, or even suppress it, and are therefore well suited to correctly model the beam properties. For efficient parallelization of the PIC algorithm, however, localized solvers are inevitable. Arbitrary order pseudo-spectral methods provide this needed locality. Yet, these methods can again be prone to NCR. Here, we show that acceptably low solver orders are sufficient to correctly model the physics of interest, while allowing for parallel computation by domain decomposition.