ترغب بنشر مسار تعليمي؟ اضغط هنا

A study in using MICROMEGAS to improve particle identification with the TAMU-MDM focal plane detector

57   0   0.0 ( 0 )
 نشر من قبل Livius Trache
 تاريخ النشر 2019
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

A MICROMEGAS detection amplifier has been incorporated into the design of the TAMU MDM focal plane detector with the purpose of improving the energy resolution and thus, the particle identification. Beam tests showed a factor of 2 improvement over the original design, from 10-12% to 4-6%, for ions with A<40 at E/A around 10-20 MeV.



قيم البحث

اقرأ أيضاً

The focal-plane detector system for the KArlsruhe TRItium Neutrino (KATRIN) experiment consists of a multi-pixel silicon p-i-n-diode array, custom readout electronics, two superconducting solenoid magnets, an ultra high-vacuum system, a high-vacuum s ystem, calibration and monitoring devices, a scintillating veto, and a custom data-acquisition system. It is designed to detect the low-energy electrons selected by the KATRIN main spectrometer. We describe the system and summarize its performance after its final installation.
128 - Matthew Barrett 2013
The Belle-II experiment and superKEKB accelerator will form a next generation B-factory at KEK, capable of running at an instantaneous luminosity 40 times higher than the Belle detector and KEKB. This will allow for the elucidation of many facets of the Standard Model by performing precision measurements of its parameters, and provide sensitivity to many rare decays that are currently inaccessible. This will require major upgrades to both the accelerator and detector subsystems. The imaging Time-of-propagation (iTOP) detector will be a new subdetector of Belle-II that will perform an integral role in Particle identification (PID). It will comprise 16 modules between the tracking detectors and calorimeter; each module consisting of a quartz radiator, approximately 2.5m in length, instrumented with an array of 32 micro-channel plate photodetectors (MCP-PMTs). The passage of charged particles through the quartz will produce a cone of Cherenkov photons that will propagate along the length of the quartz, and be detected by the MCP-PMTs. The excellent spatial, and timing resolution (of 50 picoseconds) of the iTOP system will provide superior particle identification capabilities, particularly allowing for enhanced discrimination between pions and kaons that will be essential for many of the key measurements to performed. The status of the construction of the iTOP subdetector, and performance studies of prototypes at beam tests will be presented, together with prospects for physics measurements that will utilise the PID capabilities of the iTOP system.
We have developed MICROMEGAS (MICRO MEsh GASeous) detectors for detecting {alpha} particles emitted from an 241-Am standard source. The voltage applied to the ionization region of the detector is optimized for stable operation at room temperature and atmospheric pressure. The energy of {alpha} particles from the 241-Am source can be varied by changing the flight path of the {alpha} particle from the 241 Am source. The channel numbers of the experimentally-measured pulse peak positions for different energies of the {alpha} particles are associated with the energies deposited by the alpha particles in the ionization region of the detector as calculated by using GEANT4 simulations; thus, the energy calibration of the MICROMEGAS detector for {alpha} particles is done. For the energy calibration, the thickness of the ionization region is adjusted so that {alpha} particles may completely stop in the ionization region and their kinetic energies are fully deposited in the region. The efficiency of our MICROMEGAS detector for {alpha} particles under the present conditions is found to be ~ 97.3 %.
The paper describes a method of the charged particle identification, developed for the mbox{CMD-3} detector, installed at the VEPP-2000 $e^{+}e^{-}$ collider. The method is based on the application of the boosted decision trees classifiers, trained f or the optimal separation of electrons, muons, pions and kaons in the momentum range from 100 to $1200~{rm MeV}/c$. The input variables for the classifiers are linear combinations of the energy depositions of charged particles in 12 layers of the liquid xenon calorimeter of the mbox{CMD-3}. The event samples for training of the classifiers are taken from the simulation. Various issues of the detector response tuning in simulation and calibration of the calorimeter strip channels are considered. Application of the method is illustrated by the examples of separation of the $e^+e^-(gamma)$ and $pi^+pi^-(gamma)$ final states and of selection of the $K^+K^-$ final state at high energies.
68 - S. Longo , J.M. Roney , C. Cecchi 2020
This paper describes the implementation and performance of CsI(Tl) pulse shape discrimination for the Belle II electromagnetic calorimeter, representing the first application of CsI(Tl) pulse shape discrimination for particle identification at an ele ctron-positron collider. The pulse shape characterization algorithms applied by the Belle II calorimeter are described. Control samples of $gamma$, $mu^+$, $pi^pm$, $K^pm$ and $p/bar{p}$ are used to demonstrate the significant insight into the secondary particle composition of calorimeter clusters that is provided by CsI(Tl) pulse shape discrimination. Comparisons with simulation are presented and provide further validation for newly developed CsI(Tl) scintillation response simulation techniques, which when incorporated with GEANT4 simulations allow the particle dependent scintillation response of CsI(Tl) to be modelled. Comparisons between data and simulation also demonstrate that pulse shape discrimination can be a new tool to identify sources of improvement in the simulation of hadronic interactions in materials. The $K_L^0$ efficiency and photon-as-hadron fake-rate of a multivariate classifier that is trained to use pulse shape discrimination is presented and comparisons are made to a shower-shape based approach. CsI(Tl) pulse shape discrimination is shown to reduce the photon-as-hadron fake-rate by over a factor of 3 at photon energies of 0.2 GeV and over a factor 10 at photon energies of 1 GeV.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا