ترغب بنشر مسار تعليمي؟ اضغط هنا

Multiphoton Label-Free ex-vivo imaging using a custom-built dual-wavelength microscope with chromatic aberrations compensation

107   0   0.0 ( 0 )
 نشر من قبل Andrea Filippi
 تاريخ النشر 2017
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

Label-Free Multiphoton Microscopy is a very powerful optical microscopy that can be applied to study samples with no need for exogenous fluorescent probes, keeping the main benefits of a Multiphoton approach, like longer penetration depths and intrinsic optical sectioning, while opening the possibility of serial examinations with different kinds of techniques. Among the many variations of Label-Free MPM, Higher Harmonic Generation (HHG) is one of the most intriguing due to its generally low photo-toxicity, which enables the examination of specimens particularly susceptible to photo-damages. HHG and common Two-Photon Microscopy (TPM) are well-established techniques, routinely used in several research fields. However, they require a significant amount of fine-tuning in order to be fully exploited and, usually, the optimized conditions greatly differ, making them quite difficult to perform in parallel without any compromise on the extractable information. Here we present our custom-built Multiphoton microscope capable of performing simultaneously TPM and HHG without any kind of compromise on the results thanks to two, separate, individually optimized laser sources with full chromatic aberration compensation. We also apply our setup to the examination of a plethora of ex vivo samples in order to prove the significant advantages of our approach.

قيم البحث

اقرأ أيضاً

We present the first label-free, non-contact, in-vivo imaging of the ocular vasculature using photoacoustic remote sensing (PARS) microscopy. Both anterior and posterior segments mouse eye were imaged. Vasculature of iris, sclera and retina tissues w ere clearly resolved. To best of our knowledge this the first study showing non-contact photoacoustic imaging conducted on in-vivo ocular tissue. We believe that PARS microscopy has the potential to advance the diagnosis and treatment of ocular diseases.
We present a laser scanning reflection-matrix microscopy combining the scanning of laser focus and the wide-field mapping of the electric field of the backscattered waves for eliminating higher-order aberrations even in the presence of strong multipl e light scattering noise. Unlike conventional confocal laser scanning microscopy, we record the amplitude and phase maps of reflected waves from the sample not only at the confocal pinhole, but also at other non-confocal points. These additional measurements lead us to constructing a time-resolved reflection matrix, with which the sample-induced aberrations for the illumination and detection pathways are separately identified and corrected. We realized in vivo reflectance imaging of myelinated axons through an intact skull of a living mouse with the spatial resolution close to the ideal diffraction limit. Furthermore, we demonstrated near-diffraction-limited multiphoton imaging through an intact skull by physically correcting the aberrations identified from the reflection matrix. The proposed method is expected to extend the range of applications, where the knowledge of the detailed microscopic information deep within biological tissues is critical.
We present a simple and effective method to eliminate system aberrations and speckle noise in quantitative phase imaging. Using spiral integration, complete information about system aberration is calculated from three laterally shifted phase images. The present method is especially useful when measuring confluent samples in which acquisition of background area is challenging. To demonstrate validity and applicability, we present measurements of various types of samples including microspheres, HeLa cells, and mouse brain tissue. Working conditions and limitations are systematically analyzed and discussed.
In quantum mechanics, entanglement and correlations are not just a mere sporadic curiosity, but rather common phenomena at the basis of an interacting quantum system. In electron microscopy, such concepts have not been extensively explored yet in all their implications; in particular, inelastic scattering can be reanalyzed in terms of correlation between the electron beam and the sample. While classical inelastic scattering simply implies loss of coherence in the electron beam, performing a joint measurement on the electron beam and the sample excitation could restore the coherence and the lost information. Here, we propose to exploit joint measurement in electron microscopy for a surprising and counter-intuitive application of the concept of ghost imaging. Ghost imaging, first proposed in quantum photonics, can be applied partially in electron microscopy by performing joint measurement between the portion of the transmitted electron beam and a photon emitted from the sample reaching a bucket detector. This would permit us to form a one-dimensional virtual image of an object that even has not interacted with the electron beam directly. This technique is extremely promising for low-dose imaging that requires the minimization of radiation exposure for electron-sensitive materials, because the object interacts with other form of waves, e.g., photons/surface plasmon polaritons, and not the electron beam. We demonstrate this concept theoretically for any inelastic electron-sample interaction in which the electron excites a single quantum of a collective mode, such as a photon, plasmon, phonon, magnon, or any optical polariton.
Compared to imaging in the visible and near-infrared regions below 900 nm, imaging in the second near-infrared window (NIR-II, 1000-1700 nm) is a promising method for deep-tissue high-resolution optical imaging in vivo mainly due to the reduced scatt ering of photons traversing through biological tissues. Herein, semiconducting single-walled carbon nanotubes with large diameters were used for in vivo fluorescence imaging in the long-wavelength NIR region (1500-1700 nm, NIR-IIb). With this imaging agent, 3-4 um wide capillary blood vessels at a depth of about 3 mm could be resolved. Meanwhile, the blood-flow speeds in multiple individual vessels could be mapped simultaneously. Furthermore, NIR-IIb tumor imaging of a live mouse was explored. NIR-IIb imaging can be generalized to a wide range of fluorophores emitting at up to 1700 nm for high-performance in vivo optical imaging.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا