DALI2: A NaI(Tl) detector array for measurements of $gamma$ rays from fast nuclei

149   0   0.0 ( 0 )
 نشر من قبل Satoshi Takeuchi
 تاريخ النشر 2014
  مجال البحث
والبحث باللغة English




اسأل ChatGPT حول البحث

A NaI(Tl) detector array called DALI2 (Detector Array for Low Intensity radiation 2) has been constructed for in-beam $gamma$-ray spectroscopy experiments with fast radioactive isotope (RI) beams. It consists typically of 186 NaI(Tl) scintillators covering polar angles from $sim$15$^{circ}$ to $sim$160$^{circ}$ with an average angular resolution of 6$^{circ}$ in full width at half maximum. Its high granularity (good angular resolution) enables Doppler-shift corrections that result in, for example, 10% energy resolution and 20% full-energy photopeak efficiency for 1-MeV $gamma$ rays emitted from fast-moving nuclei (velocities of $v/c simeq 0.6$). DALI2 has been employed successfully in numerous experiments using fast RI beams with velocities of $v/c = 0.3 - 0.6$ provided by the RIKEN RI Beam Factory.



قيم البحث

اقرأ أيضاً

We have built a CsI(Tl) gamma-ray detector array for the NPDGamma experiment to search for a small parity-violating directional asymmetry in the angular distribution of 2.2 MeV gamma-rays from the capture of polarized cold neutrons by protons with a sensitivity of several ppb. The weak pion-nucleon coupling constant can be determined from this asymmetry. The small size of the asymmetry requires a high cold neutron flux, control of systematic errors at the ppb level, and the use of current mode gamma-ray detection with vacuum photo diodes and low-noise solid-state preamplifiers. The average detector photoelectron yield was determined to be 1300 photoelectrons per MeV. The RMS width seen in the measurement is therefore dominated by the fluctuations in the number of gamma rays absorbed in the detector (counting statistics) rather than the intrinsic detector noise. The detectors were tested for noise performance, sensitivity to magnetic fields, pedestal stability and cosmic background. False asymmetries due to gain changes and electronic pickup in the detector system were measured to be consistent with zero to an accuracy of $10^{-9}$ in a few hours. We report on the design, operating criteria, and the results of measurements performed to test the detector array.
The scintillation light output of a pure and a Thallium doped Sodium Iodide (NaI) crystal under irradiation with 5.486MeV alpha -particles has been measured over a temperature range from 1.7K to 300K. Estimates of the decay time constant at three sel ected temperatures are given. For pure NaI an increase in light yield towards low temperatures could be confirmed and measured at higher precision. For NaI(Tl) below 60K an increase in light output has been found.
The Korea Invisible Mass Search (KIMS) collaboration has developed low-background NaI(Tl) crystals that are suitable for the direct detection of WIMP dark matter. With experience built on the KIMS-CsI programs, the KIMS-NaI experiment will consist of a 200~kg NaI(Tl) crystal array surrounded by layers of shielding structures and will be operated at the Yangyang underground laboratory. The goal is to provide an unambiguous test of the DAMA/LIBRAs annual modulation signature. Measurements of six prototype crystals show progress in the reduction of internal contaminations of radioisotopes. Based on our understanding of these measurements, we expect to achieve a background level in the final detector configuration that is less than 1~count/day/keV/kg for recoil energies around 2~keV. The annual modulation sensitivity for the KIMS-NaI experiment shows that an unambiguous 7$sigma$ test of the DAMA/LIBRA signature would be possible with a 600~kg$cdot$year exposure with this system.
101 - K. Hauschild 2006
With the aid of the Geant4 Monte Carlo simulation package a new detection system has been designed for the focal plane of the recoil separator VASSILISSA situated at the Flerov Laboratory of Nuclear Reactions, JINR, Dubna. GABRIELA (Gamma Alpha Beta Recoil Investigations with the Electromagnetic Analyser VASSILISSA) has been optimised to detect the arrival of reaction products and their subsequent radioactive decays involving the emission of alpha- and beta-particles, fission fragments, gamma- and X-rays, and conversion electrons. The new detector system is described and the results of the first commissioning experiments are presented.
Discrimination of the detection of fast neutrons and gamma rays in a liquid scintillator detector has been investigated using digital pulse-processing techniques. An experimental setup with a 252Cf source, a BC-501 liquid scintillator detector, and a BaF2 detector was used to collect waveforms with a 100 Ms/s, 14 bit sampling ADC. Three identical ADCs were combined to increase the sampling frequency to 300 Ms/s. Four different digital pulse-shape analysis algorithms were developed and compared to each other and to data obtained with an analogue neutron-gamma discrimination unit. Two of the digital algorithms were based on the charge comparison method, while the analogue unit and the other two digital algorithms were based on the zero-crossover method. Two different figure-of-merit parameters, which quantify the neutron-gamma discrimination properties, were evaluated for all four digital algorithms and for the analogue data set. All of the digital algorithms gave similar or better figure-of-merit values than what was obtained with the analogue setup. A detailed study of the discrimination properties as a function of sampling frequency and bit resolution of the ADC was performed. It was shown that a sampling ADC with a bit resolution of 12 bits and a sampling frequency of 100 Ms/s is adequate for achieving an optimal neutron-gamma discrimination for pulses having a dynamic range for deposited neutron energies of 0.3-12 MeV. An investigation of the influence of the sampling frequency on the time resolution was made. A FWHM of 1.7 ns was obtained at 100 Ms/s.