ترغب بنشر مسار تعليمي؟ اضغط هنا

A Current Mode Detector Array for Gamma-Ray Asymmetry Measurements

184   0   0.0 ( 0 )
 نشر من قبل Michael Gericke
 تاريخ النشر 2004
  مجال البحث
والبحث باللغة English




اسأل ChatGPT حول البحث

We have built a CsI(Tl) gamma-ray detector array for the NPDGamma experiment to search for a small parity-violating directional asymmetry in the angular distribution of 2.2 MeV gamma-rays from the capture of polarized cold neutrons by protons with a sensitivity of several ppb. The weak pion-nucleon coupling constant can be determined from this asymmetry. The small size of the asymmetry requires a high cold neutron flux, control of systematic errors at the ppb level, and the use of current mode gamma-ray detection with vacuum photo diodes and low-noise solid-state preamplifiers. The average detector photoelectron yield was determined to be 1300 photoelectrons per MeV. The RMS width seen in the measurement is therefore dominated by the fluctuations in the number of gamma rays absorbed in the detector (counting statistics) rather than the intrinsic detector noise. The detectors were tested for noise performance, sensitivity to magnetic fields, pedestal stability and cosmic background. False asymmetries due to gain changes and electronic pickup in the detector system were measured to be consistent with zero to an accuracy of $10^{-9}$ in a few hours. We report on the design, operating criteria, and the results of measurements performed to test the detector array.

قيم البحث

اقرأ أيضاً

A NaI(Tl) detector array called DALI2 (Detector Array for Low Intensity radiation 2) has been constructed for in-beam $gamma$-ray spectroscopy experiments with fast radioactive isotope (RI) beams. It consists typically of 186 NaI(Tl) scintillators co vering polar angles from $sim$15$^{circ}$ to $sim$160$^{circ}$ with an average angular resolution of 6$^{circ}$ in full width at half maximum. Its high granularity (good angular resolution) enables Doppler-shift corrections that result in, for example, 10% energy resolution and 20% full-energy photopeak efficiency for 1-MeV $gamma$ rays emitted from fast-moving nuclei (velocities of $v/c simeq 0.6$). DALI2 has been employed successfully in numerous experiments using fast RI beams with velocities of $v/c = 0.3 - 0.6$ provided by the RIKEN RI Beam Factory.
101 - K. Hauschild 2006
With the aid of the Geant4 Monte Carlo simulation package a new detection system has been designed for the focal plane of the recoil separator VASSILISSA situated at the Flerov Laboratory of Nuclear Reactions, JINR, Dubna. GABRIELA (Gamma Alpha Beta Recoil Investigations with the Electromagnetic Analyser VASSILISSA) has been optimised to detect the arrival of reaction products and their subsequent radioactive decays involving the emission of alpha- and beta-particles, fission fragments, gamma- and X-rays, and conversion electrons. The new detector system is described and the results of the first commissioning experiments are presented.
The GALILEO $gamma$-ray spectrometer has been constructed at the Legnaro National Laboratory of INFN (LNL-INFN). It can be coupled to advanced ancillary devices which allows nuclear structure studies employing the variety of in-beam $gamma$-ray spect roscopy methods. Such studies benefit from reactions induced by the intense stable beams delivered by the Tandem-ALPI-PIAVE accelerator complex and by the radioactive beams which will be provided by the SPES facility. In this paper we outline two experiments performed within the experimental campaign at GALILEO coupled to the EUCLIDES Si-ball and the Neutron Wall array. The first one was aimed at spectroscopic studies in A=31 mirror nuclei and the second one at measurements of lifetimes of excited states in nuclei in the vicinity of $^{100}$Sn.
High statistics measurements of the photon asymmetry $mathrm{Sigma}$ for the $overrightarrow{gamma}$p$rightarrowpi^{0}$p reaction have been made in the center of mass energy range W=1214-1450 MeV. The data were measured with the MAMI A2 real photon b eam and Crystal Ball/TAPS detector systems in Mainz, Germany. The results significantly improve the existing world data and are shown to be in good agreement with previous measurements, and with the MAID, SAID, and Bonn-Gatchina predictions. We have also combined the photon asymmetry results with recent cross-section measurements from Mainz to calculate the profile functions, $check{mathrm{Sigma}}$ (= $sigma_{0}mathrm{Sigma}$), and perform a moment analysis. Comparison with calculations from the Bonn-Gatchina model shows that the precision of the data is good enough to further constrain the higher partial waves, and there is an indication of interference between the very small $F$-waves and the $N(1520) 3/2^{-}$ and $N(1535) 1/2^{-}$ resonances.
46 - N. Produit , F. Barao , S. Deluit 2005
The design and the simulated performances of a compact detector dedicated to the measurement of GRB photon polarization is presented. Such a detector would permit to answer the question ``are most of the GRB strongly polarized? in a mission of one year in space.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا