ترغب بنشر مسار تعليمي؟ اضغط هنا

Digital pulse-shape discrimination of fast neutrons and gamma rays

90   0   0.0 ( 0 )
 نشر من قبل P\\\"ar-Anders S\\\"oderstr\\\"om
 تاريخ النشر 2008
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

Discrimination of the detection of fast neutrons and gamma rays in a liquid scintillator detector has been investigated using digital pulse-processing techniques. An experimental setup with a 252Cf source, a BC-501 liquid scintillator detector, and a BaF2 detector was used to collect waveforms with a 100 Ms/s, 14 bit sampling ADC. Three identical ADCs were combined to increase the sampling frequency to 300 Ms/s. Four different digital pulse-shape analysis algorithms were developed and compared to each other and to data obtained with an analogue neutron-gamma discrimination unit. Two of the digital algorithms were based on the charge comparison method, while the analogue unit and the other two digital algorithms were based on the zero-crossover method. Two different figure-of-merit parameters, which quantify the neutron-gamma discrimination properties, were evaluated for all four digital algorithms and for the analogue data set. All of the digital algorithms gave similar or better figure-of-merit values than what was obtained with the analogue setup. A detailed study of the discrimination properties as a function of sampling frequency and bit resolution of the ADC was performed. It was shown that a sampling ADC with a bit resolution of 12 bits and a sampling frequency of 100 Ms/s is adequate for achieving an optimal neutron-gamma discrimination for pulses having a dynamic range for deposited neutron energies of 0.3-12 MeV. An investigation of the influence of the sampling frequency on the time resolution was made. A FWHM of 1.7 ns was obtained at 100 Ms/s.

قيم البحث

اقرأ أيضاً

88 - P.-A. Soderstrom 2008
The basic principles of detection of fast neutrons with liquid scintillator detectors are reviewed, together with a real example in the form of the Neutron Wall array. Two of the challenges in neutron detection, discrimination of neutrons and gamma r ays and identification of cross talk between detectors due to neutron scattering, are briefly discussed, as well as possible solutions to these problems. The possibilities of using digital techniques for pulse-shape discrimination are examined. Results from a digital and anal
79 - Q. Riffard 2016
MIMAC (MIcro-TPC MAtrix of Chambers) is a directional WIMP Dark Matter detector project. Direct dark matter experiments need a high level of electron/recoil discrimination to search for nuclear recoils produced by WIMP-nucleus elastic scattering. In this paper, we proposed an original method for electron event rejection based on a multivariate analysis applied to experimental data acquired using monochromatic neutron fields. This analysis shows that a $10^5$ rejection power is reachable for electron/recoil discrimination. Moreover, the efficiency was estimated by a Monte-Carlo simulation showing that a 105 electron rejection power is reached with a $86.49pm 0.17$% nuclear recoil efficiency considering the full energy range and $94.67pm0.19$% considering a 5~keV lower threshold.
139 - L.Bardelli , M.Bini , P.G.Bizzeti 2007
The light output, $alpha/beta$ ratio, and pulse shape have been investigated at $-25^circ$ C with PbWO$_4$ crystal scintillators undoped, and doped by F, Eu, Mo, Gd and S. The fast $0.01-0.06 mu$s and middle $0.1-0.5 mu$s components of scintillation decay were observed for all the samples. Slow components of scintillation signal with the decay times $1-3 mu$s and $13-28 mu$s with the total intensity up to $approx50%$ have been recognized for several samples doped by Molybdenum. We found some indications of a pulse-shape discrimination between $alpha$ particles and $gamma$ quanta with PbWO$_4$ (Mo doped) crystal scintillators.
The cross-sections of prompt gamma-ray production from $^{nat}$Sn and $^{nat}$C elements induced by 14.1-MeV neutrons were measured. The time-of-flight technique was used for n-gamma discrimination. The experimental results were compared with theoret ical calculations performed by Empire 3.2 and Talys 1.6 codes using different models for photon strength function and nuclear level density.
A correlation term ${{ sigma}_{n} }cdot ({ k_{n}times k_gamma}) $ in the ${}^{139}{rm La}(vec{n},gamma)$ reaction has been studied utilizing epithermal polarized neutrons and germanium detectors. The transverse asymmetry for single $gamma$-ray transi tion was measured to be $0.60pm0.19$ in the $p$-wave resonance.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا