99 - M. Cortesi , R. Zboray , R. Adams 2012
The conceptual design and operational principle of a novel high-efficiency, fast neutron imaging detector based on THGEM, intended for future fan-beam transmission tomography applications, is described. We report on a feasibility study based on theor etical modeling and computer simulations of a possible detector configuration prototype. In particular we discuss results regarding the optimization of detector geometry, estimation of its general performance, and expected imaging quality: it has been estimated that detection efficiency of around 5-8% can be achieved for 2.5MeV neutrons; spatial resolution is around one millimeter with no substantial degradation due to scattering effects. The foreseen applications of the imaging system are neutron tomography in non-destructive testing for the nuclear energy industry, including examination of spent nuclear fuel bundles, detection of explosives or drugs, as well as investigation of thermal hydraulics phenomena (e.g., two-phase flow, heat transfer, phase change, coolant dynamics, and liquid metal flow).
The properties of UV-photon imaging detectors consisting of CsI-coated THGEM electron multipliers are summarized. New results related to detection of Cherenkov light (RICH) and scintillation photons in noble liquid are presented.
The operation of single-, double- and triple-THGEM UV-detectors with reflective CsI photocathodes (CsI-THGEM) in Ne/CH4 and Ne/CF4 mixtures was investigated in view of their potential applications in RICH. The studies were carried out with UV, x-rays and {beta}-electrons and focused on the maximum achievable gain, discharge probability, cathode excitation effects and long-term gain stability. Comparative studies under similar conditions were made in CH4, CF4 and Ne/CF4, with a MWPC coupled to a reflective CsI photocathode (CsI-MWPC). It was found that at counting rates <= 10 Hz/mm^2 the maximum achievable gain of CsI-THGEMs is determined by the Raether limit; at counting rates > 10 Hz/mm^2 it dropped with rate. In all cases investigated the attainable CsI-THGEM gain was significantly higher than that of the CsI-MWPC, under similar conditions. Furthermore, the CsI-THGEM UV-detector suffered fewer cathode-excitation induced effects as compared to CsI-MWPC and had better stability at high counting rates.
The article deals with the detection efficiency of UV-photon detectors consisting of Thick Gas Electron Multipliers (THGEM) coated with CsI photocathode, operated in atmospheric Ne/CH4 and Ne/CF4 mixtures. We report on the photoelectron extraction ef ficiency from the photocathode into these gas mixtures, and on the photoelectron collection efficiency into the THGEM holes. Full collection efficiency was reached in all gases investigated, in some cases at relatively low multiplication. High total detector gains for UV photons, in excess of 10^5, were reached at relatively low operation voltages with a single THGEM element. We discuss the photon detection efficiency in the context of possible application to RICH.
The operation of Thick Gaseous Electron Multipliers (THGEM) in Ne and Ne/CH4 mixtures, features high multiplication factors at relatively low operation potentials, in both single- and double-THGEM configurations. We present some systematic data measu red with UV-photons and soft x-rays, in various Ne mixtures. It includes gain dependence on hole diameter and gas purity, photoelectron extraction efficiency from CsI photocathodes into the gas, long-term gain stability and pulse rise-time. Position resolution of a 100x100 mm^2 X-rays imaging detector is presented. Possible applications are discussed.
236 - A.Breskin , R. Alon , M. Cortesi 2008
We briefly review the concept and properties of the Thick GEM (THGEM); it is a robust, high-gain gaseous electron multiplier, manufactured economically by standard printed-circuit drilling and etching technology. Its operation and structure resemble that of GEMs but with 5 to 20-fold expanded dimensions. The millimeter-scale hole-size results in good electron transport and in large avalanche-multiplication factors, e.g. reaching 10^7 in double-THGEM cascaded single-photoelectron detectors. The multipliers material, parameters and shape can be application-tailored; it can operate practically in any counting gas, including noble gases, over a pressure range spanning from 1 mbar to several bars; its operation at cryogenic (LAr) conditions was recently demonstrated. The high gain, sub-millimeter spatial resolution, high counting-rate capability, good timing properties and the possibility of industrial production capability of large-area robust detectors, pave ways towards a broad spectrum of potential applications; some are discussed here in brief.
85 - M. Cortesi , R. Alon , R. Chechik 2007
We present the results of our recent studies on a Thick Gas Electron Multiplier (THGEM)-based imaging detector prototype. It consists of two 100x100 mm^2 THGEM electrodes in cascade, coupled to a resistive anode. The event location is recorded with a 2D double-sided readout electrode equipped with discrete delay-lines and dedicated electronics. The THGEM electrodes, produced by standard printed-circuit board and mechanical drilling techniques, a 0.4 mm thick with 0.5 mm diameter holes spaced by 1 mm. Localization resolutions of about 0.7 mm (FWHM) were measured with soft x-rays, in a detector operated with atmospheric-pressure Ar/CH4; good linearity and homogeneity were achieved. We describe the imaging-detector layout, the resistive-anode 2D readout system and the imaging properties. The THGEM has numerous potential applications that require large-area imaging detectors, with high-rate capability, single-electron sensitivity and moderate (sub-mm) localization resolution.
243 - R. Alon , J. Miyamoto , M. Cortesi 2007
We present the results of our recent studies of a Thick Gaseous Electron Multiplier (THGEM)-based detector, operated in Ar, Xe and Ar:Xe (95:5) at various gas pressures. Avalanche-multiplication properties and energy resolution were investigated with soft x-rays for different detector configurations and parameters. Gains above 10E4 were reached in a double-THGEM detector, at atmospheric pressure, in all gases, in almost all the tested conditions; in Ar:Xe (95:5) similar gains were reached at pressures up to 2 bar. The energy resolution dependence on the gas, pressure, hole geometry and electric fields was studied in detail, yielding in some configurations values below 20% FWHM with 5.9 keV x-rays.
214 - M. Cortesi 2007
Selective accumulation of B-10 compound in tumour tissue is a fundamental condition for the achievement of BNCT (Boron Neutron Capture Therapy), since the effectiveness of therapy irradiation derives just from neutron capture reaction of B-10. Hence, the determination of the B-10 concentration ratio, between tumour and healthy tissue, and a control of this ratio, during the therapy, are essential to optimise the effectiveness of the BNCT, which it is known to be based on the selective uptake of B-10 compound. In this work, experimental methods are proposed and evaluated for the determination in vivo of B-10 compound in biological samples, in particular based on neutron radiography and gammaray spectroscopy by telescopic system. Measures and Monte Carlo calculations have been performed to investigate the possibility of executing imaging of the 10B distribution, both by radiography with thermal neutrons, using 6LiF/ZnS:Ag scintillator screen and a CCD camera, and by spectroscopy, based on the revelation of gamma-ray reaction products from B-10 and the H. A rebuilding algorithm has been implemented. The present study has been done for the standard case of B-10 uptake, as well as for proposed case in which, to the same carrier, is also synthesized Gd-157, in the amount of is used like a contrast agent in NMRI.