Do you want to publish a course? Click here

Titanium Recovery from its Aqueous Media by 3-Acetylpentane-2,4-Dione as Reagent

استرجاع التيتانيوم من أوساطه المائية باستخدام الكاشف أسيتيل بنتان- 2،4 – دايون

1388   0   3   0 ( 0 )
 Publication date 2010
  fields Chemistry
and research's language is العربية
 Created by Shamra Editor




Ask ChatGPT about the research

3-acetylpentane-2,4-dione (AD) was synthesized and characterized using elemental analysis and IR spectroscopy, in order to examine it as an extractant for recovery of titanium from aqueous acidic media. Various factors, which affect recovery procedure as nature of acids, titanium concentration, acid concentration, type of diluents, and interfering ions, have been studied. It is shown to be a very effective extractant for titanium (IV) from perchloric acid medium, however, the time of extraction is very long (10 min). The extraction of titanium is independent of the initial metal ion concentration. Regarding competition among impurity metal ions, iron (III) seems to be the most competitive ion which could be avoided using fluoride ions as masking agent. The stripping of titanium was investigated using mixtures of 0.50 M NaF and 0.10 NaCl. The stripping procedure was very fast and the yield was 99.71%. The results of this investigation suggest that, it’s highly recommended to use the synthesized compound as extractant for titanium ions from its acidic media.


Artificial intelligence review:
Research summary
تتناول هذه الدراسة استخراج واسترجاع التيتانيوم من المحاليل المائية الحمضية باستخدام مركب 3-أسيتيلبنتان-2,4-ديون (AD) كمستخلص. تم تحضير المركب وتحليله باستخدام التحليل العنصري وقياس الطيف بالأشعة تحت الحمراء. تم دراسة تأثير عدة عوامل على عملية الاستخلاص مثل نوع الأحماض، تركيز التيتانيوم، تركيز الحمض، نوع المذيبات، والأيونات المتداخلة. أظهرت النتائج أن المركب AD فعال جداً في استخلاص التيتانيوم (IV) من وسط حمض البيركلوريك، لكن وقت الاستخلاص طويل (10 دقائق). كان الاستخلاص مستقلاً عن تركيز أيونات التيتانيوم الأولية. بالنسبة للتداخل بين الأيونات المعدنية الشائبة، كان الحديد (III) هو الأكثر تنافسية ويمكن تجنبه باستخدام أيونات الفلوريد كعامل قناع. تم التحقيق في عملية نزع التيتانيوم باستخدام خليط من 0.50 M NaF و0.10 M NaCl، وكانت العملية سريعة جداً وبلغت نسبة العائد 99.71%. توصي الدراسة باستخدام المركب المحضر كمستخلص لأيونات التيتانيوم من المحاليل الحمضية.
Critical review
دراسة نقدية: تقدم هذه الدراسة مساهمة قيمة في مجال استخلاص التيتانيوم من المحاليل الحمضية باستخدام مركب جديد. ومع ذلك، هناك بعض النقاط التي يمكن تحسينها. أولاً، على الرغم من فعالية المركب AD، إلا أن وقت الاستخلاص لا يزال طويلاً نسبياً مقارنة ببعض المستخلصات الأخرى المذكورة في الأدبيات. ثانياً، لم يتم التطرق بشكل كافٍ إلى الآثار البيئية لاستخدام المركب والمذيبات المختلفة. ثالثاً، كان من الممكن تقديم تحليل اقتصادي لتكلفة استخدام المركب AD مقارنة بالمستخلصات الأخرى. وأخيراً، قد يكون من المفيد إجراء تجارب إضافية لتحديد مدى استقرار المركب AD في ظروف مختلفة ومدى تأثيره على أنواع أخرى من الأيونات المعدنية.
Questions related to the research
  1. ما هو الهدف الرئيسي من الدراسة؟

    الهدف الرئيسي من الدراسة هو تحضير مركب جديد يسمى 3-أسيتيلبنتان-2,4-ديون (AD) وتقييم إمكانية استخدامه كمستخلص لأيونات التيتانيوم (IV) من المحاليل المائية الحمضية.

  2. ما هي العوامل التي تم دراستها لتقييم فعالية المركب AD؟

    تم دراسة تأثير عدة عوامل على عملية الاستخلاص مثل نوع الأحماض، تركيز التيتانيوم، تركيز الحمض، نوع المذيبات، والأيونات المتداخلة.

  3. ما هي النتائج الرئيسية التي توصلت إليها الدراسة بشأن فعالية المركب AD؟

    أظهرت النتائج أن المركب AD فعال جداً في استخلاص التيتانيوم (IV) من وسط حمض البيركلوريك، وأن الاستخلاص مستقل عن تركيز أيونات التيتانيوم الأولية. كما أن عملية نزع التيتانيوم باستخدام خليط من 0.50 M NaF و0.10 M NaCl كانت سريعة جداً وبلغت نسبة العائد 99.71%.

  4. ما هي الأيونات التي تتداخل بشكل كبير مع عملية استخلاص التيتانيوم باستخدام المركب AD؟

    كان الحديد (III) هو الأيون الأكثر تنافسية ويمكن تجنبه باستخدام أيونات الفلوريد كعامل قناع.


References used
Allal, K. M. Hauchard, D. Stambouli, M. Pareau, D. Durand, G. (1997). Diluent extraction of titanium by tributylphosphate, trioctylphosphine oxide and decanol from chloride media. Hydrometallurgy, 45, 113– 128
Basudev, S., Jinki, J. Jae-Chun Lee. Gae-Ho Lee. (2007). Extraction of Co (II) by supported liquid membrane and diluent extraction using Cyanex 272 as an extractant. A comparison study Journal of Membrane Science; 288, 139–148
Biswas-A, R. K, Begum, D. A. (1998). Diluent extrcation of tetravalent titanium from chloride solution by di-2-ethylhexyl phosphoric acid in kerosene. Hydrometallurgy, 49, 263–274
rate research

Read More

The possibility of formating a colored complex between Fe2+ ions and 4-Hydroxy-3- [[(2-hydroxy phenyl) methylene] amino] benzene Sulphonic Acid (HVMAB) was studied spectrophotometric method for determination of iron in aqueous solutions. The reagen t reacts in aqueous medium at pH=5 to give an orange complex with maximum absorbance λmax=415nm.
Syrian natural zeolit was used to study the adsorption of phenol from aqueous solutions. Batch method was used to study the adsorption process. The results showed that the adsorption process accurs rabidly at the first time and the equilibrium ach ieved after 120min . The adsorption process performed in the rang of PH (3-10). The adsorption of phenol increased by increasing of PH value up to(6-7) and then decreased. The temperature affect the adsorption process and the results showed that the increasing of the temperature leads to decreasing of the adsorption of phenol.The maximum adsorption amount of phenol was 8 mg/g at 25C0 when the initial concentration of phenol was 60mg/l. Adsorption amount of phenol increased when the adsorbent dosage increased up to 0.3g of zeolite. The resulted data of the adsorption isotherm were fitted with Langmuire model and the monomolecular layer adsorption formed on the surdace of the adsorbent.
Pollution by heavy metals, due to their toxic nature and other adverse effects, is one of the most serious environmental problems. Many heavy metal ions, such as mercuric ions are detected in industrial wastewaters originating from metal plating, mining activities, paint manufacture, etc. This ion isn’t biodegradable and tends to accumulate in living organisms, causing various diseases and disorders. Therefore, it should be removed from aqueous solution before discharge.
Separation with solvent extraction of Cu(II), Hg(II), and Cr(III) from aqueous solution using the ligend (HL) as a new extractant has been studied. The new acyclic Schiff Base (HL) was synthesized by reaction of 5-bromosalicylaldehyde with 2-(2-Am inoethyl)pyridine. The structure of the new compound (HL) was confirmed by using FT-IR spectra, 1H-NMR and 13CNMR spectra and mass spectra (MS). The effect of chloroform and dichloromethan as organic solvents in the metal extractions was investigated at 20oC by using UV-visible Spectrometry. The influence of pH, ligand concentration, shaking time and ratio of aqueous-to-organic phases on extraction yield was tested at 20oC. The extractability of the tested metal ions were evaluated.
A new acyclic Schiff Base(II), containing nitrogen-oxygen donor atoms was synthesized by reaction of 1,2-Bis (5-bromo-2-formyl-phenoxy) ethane with 2- (2-Aminoethyl)pyridine and characterized. The liquid-liquid extraction of transition metals such as Cu+2, Cr+3 and Uranyl-picrate (UO2)+2 from aqueous phase to the organic phase was carried out using the novel ligand. The effect of chloroform and nitrobenzene as organic solvents on the metal extractions was investigated at 20oC by using Atomic Absorption and UV-visible Spectrophotometry. The influence of pH, ligand concentration, ionic strength, shaking time and ratio of aqueous-to-organic phases on extraction yield was tested at 20oC. The extractability of the tested metal ions were valuated.
comments
Fetching comments Fetching comments
Sign in to be able to follow your search criteria
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا