Removal Of Mercuric Ions (II) From Aqueous Solutions by Chelating Resin Containing Carboxylic Groups

إزالة أيون الزئبق (II) من محاليله المائية باستخدام ريزين ممخلب ذي مجموعات وظيفية كربوكسيلية

1600   2   12   0 ( 0 )
 Publication date 2013
and research's language is العربية
 Created by Shamra Editor




Ask ChatGPT about the research

Pollution by heavy metals, due to their toxic nature and other adverse effects, is one of the most serious environmental problems. Many heavy metal ions, such as mercuric ions are detected in industrial wastewaters originating from metal plating, mining activities, paint manufacture, etc. This ion isn’t biodegradable and tends to accumulate in living organisms, causing various diseases and disorders. Therefore, it should be removed from aqueous solution before discharge.

References used
Anirudhan,T. S., and Sreekumari,S, S. (2011). Adsorptive removal of heavy metal ions from industrial effluents using activated carbon derived from waste coconut buttons. Journal of Environmental Sciences, 23(12): 1989- 1998
Lu, L. L, Chen, L. H., Shao,W.J,and Luo. F. (2010). Equilibrium and kinetic modeling of Pb(II) biosorption by a chemically modified orange peel containing cyanex 272. Journal of Chemical and Engineering Data, 55(10): 4147-4153
Ma, N., Yang, Y., Chen, S., and Zhang, Q. (2009). Preparation of amine group - containing chelating fiber for thorough removal of mercury ions, J.Hazard. Mater., 171:288-293
rate research

Read More

In this work the process of removal of zinc ions from aqueous solutions was studied using natural Syrian zeolite. Two samples were used: natural zeolite Z and modified zeolite with NaCl solution Z-Na. The removal percentage of zinc ions vs. time was determined using differential initial concentrations of Zn+2: 50,100,200,300,400 mg/L. The contact time was determined and it was 360 min. The removal of Zn+2 ions as a function of temperature and pH have been studied. It was found the increasing of removal percentage by increasing temperature and increasing when pH increasing up to ~7,then the precipitation of zinc hydroxide accurse. The Langmuire adsorption isotherm equation used to calculate the maximum sorption capacity and it was 21.7 and 28.5 mg/g for Z and Z-Na respectively. Results indicate a significant potential for the natural and modified zeolite as an adsorbent/ion-exchange materials for heavy metal removal.
The Syrian natural zeolite from om'ozon area has been studied as adsorbent for Ni(II) ions from aqueous solution. The removal of Ni(II) ions under different conditions was studied adsorption of Ni(II) enhanced with an increase of initial concentratio n, temperature and PH .all experiments were carried out at contact time 6h. The amount of Ni(II) adsorption was increased from 16.36 mgNi/g for initial solution concentration of 100mg Ni/l to 71.33 mgNi/g (for C0=1000mgNi/L). The experimental data fitted well to Langmuir isotherm. The maximum capacity was qmax=142.85mgNi/g Adsorption amount at 298K varies from 16.36mgNi/g for initial solution concentration of 100mg Ni/l to 47.93mg Ni/g(for C0=400mgNi/L) and it increases at 333K to 16.65 mgNi/g and 51mgNi/g (for C0=100 and 400 mg Ni/L )respectively. The adsorption of Ni(II) ions was increased by increasing PH up to ~ 5 and then stabilized up to PH=6 and after that the precipitation process was accured.
Syrian natural zeolit was used to study the adsorption of phenol from aqueous solutions. Batch method was used to study the adsorption process. The results showed that the adsorption process accurs rabidly at the first time and the equilibrium ach ieved after 120min . The adsorption process performed in the rang of PH (3-10). The adsorption of phenol increased by increasing of PH value up to(6-7) and then decreased. The temperature affect the adsorption process and the results showed that the increasing of the temperature leads to decreasing of the adsorption of phenol.The maximum adsorption amount of phenol was 8 mg/g at 25C0 when the initial concentration of phenol was 60mg/l. Adsorption amount of phenol increased when the adsorbent dosage increased up to 0.3g of zeolite. The resulted data of the adsorption isotherm were fitted with Langmuire model and the monomolecular layer adsorption formed on the surdace of the adsorbent.
In this search, the removal of copper and lead ions from aqeous solutions by flotation had been studied, and the effect of various factors on the removal process. The study showed that the removal of copper and lead ions was increased by increasing the value of the solution pH up to pH = 8 and the removal rate was 80%. At pH = 10 precipitation of the ions was obtained in the form of hydroxides. The removal ratio of both ions is increased by increasing the flow of the air within the solution to reach 98% for copper and 97% for lead at the flow of Q = 1000 ml/min and then the removal rate decreases to 60% with increasing airflow to Q = 1500 ml/min. The initial concentration values affect the removal process and the increase in the removal ratio was shown by increasing the initial concentration. The removal rate of copper ions was 50 % at the initial concentration of C0 = 50 mg / l to 98% at C0 = 100 mg / l. While the lead removal rate was 61 % at the initial Concentration C0 = 50 mg/l to 97% at concentration C0 = 100 mg / l.
The possibility of formating a colored complex between Fe2+ ions and 4-Hydroxy-3- [[(2-hydroxy phenyl) methylene] amino] benzene Sulphonic Acid (HVMAB) was studied spectrophotometric method for determination of iron in aqueous solutions. The reagen t reacts in aqueous medium at pH=5 to give an orange complex with maximum absorbance λmax=415nm.