Do you want to publish a course? Click here

A Study of Subantral Height Changes in Sinus Membrane Elevation with Simultaneous Implants Insertion without Bone Grafts

دراسة تغيّرات الارتفاع العظمي أسفل الجيبي في تقنية رفع مخاطية الجيب الفكي مع الإدخال المتواقت للغرسات دون مواد تطعيم

644   0   3   0 ( 0 )
 Publication date 2015
  fields Dentistry
and research's language is العربية
 Created by Shamra Editor




Ask ChatGPT about the research

This study aimed to study changes in subantral bony height when sinus membrane was elevated 6 mm without bone grafts depending on Cone Beam CT imaging. The study sample contained 18 implants placed on 11 patients of both genders, each patient underwent lateral-approach sinus-lift without bone grafts and implants were inserted simultaneously and protruded 6 mm under the elevated sinus membrane.

References used
LUNDGREN,S ANDERSON,S SENNERBY,L 2003 Spontaneous bone formation in the maxillary sinus after removal of a cyst: coincidence or consequence. Clin Implant Dent Relat Res.VOL.5, N.2 , 78-81
BRUSCHI,GB SCIPIONI,A CALESINI,G 1998 Localized management of sinus floor with simultaneous implant placement: a clinical report. Int J Oral Maxillofac Implants.VOL.13, N.2, 219- 26
WINTER,AA POLLACK,AS, ODRICH,RB 2003 Sinus/alveolar crest tenting (SACT): a new technique for implant placement in atrophic maxillary ridges without bone graft s or membranes. Int J Periodontics Restorative Dent, VOL.23, N.6, 557-65
rate research

Read More

The aim of this study was to evaluat the influence of insertion torque on the survival of immediately placed single tooth implants and bone resorption process around it . Materials and methods : 8 healthy patients received 24 conical implants ( ID I-BIO ) with sand blasted and acid etched surface . All implants inserted immediately in extraction sites, the sample were divided into two groups: The implants in the first group were inserted with insertion torque below 35 Ncm (mean 25 Ncm ) , while in the second group the implant were inserted with insertion torque above 35 Ncm (mean 52,2) .Implant survival and marginal bone loss MBL were evaluated after two , six and nine months for both groups .Results : four implants from the first group failed to osseointegrate, and statistical analysis of the data showed no correlation between insertion torque and peri- implant bone resorption .
Maxillary sinus augmentation is frequently necessary before placement of dental implants in the posterior maxilla. Besides autogenous bone graft, various bone substitutes have been used widely to augment the maxillary sinus,successful bone augmenta tion in the maxillary sinus without bone grafting and osseointegration of implants have been reported in several studies, recently, successful bone reformation in the sinus using autologous platelet-rich fibrin (PRF) concentrateas an alternative to bone grafting has been reported. The aim of this study: was to assess the useof PRF clots and membranes as the sole filling material during a lateral sinus lift with immediate implantation using radiologic exam (cone beam ct).
Graft insertion can effectively enhance the regeneration of debilitated bone. Aim: The effects of an alloplastic bone-replacing material, b-tricalcium phosphate, and of autogenous bone graft were compared.
Sinus augmentation is a common approach for patients with severe alveolar ridge atrophy. Purpose of study: The objective was to compare the hydroxyapatite + PRP with hydroxyapatite + Blood Clot in maxillary sinus grafts.
The purpose of this research is to study the effect of Subcrestal placement of dental implants on marginal bone loss in immediate implantation. The research sample comprised of 24 implants were immediately placed after extraction,12 implants have placed at Equicrestal level (6 in the maxilla and 6 mandible) served as control group and 12 impalnts (6 in the maxilla and 6 mandible) have placed at Subcrestal level served as test group. modified bleeding index MBI, probing pocket depth PPD and marginal bone loss MBL Implant survival, evaluated for both groups. Mbl were 0.85 mm in control group and 1.30 mm in test group after one year of dental emplacement The results of the present study showed that the success rate was 100% in both groups, there was no statistical difference between the test and control regarding, MBI, while there was statistical difference between the test and control regarding MBL, PPD. during periods of follow up .

suggested questions

comments
Fetching comments Fetching comments
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا