No Arabic abstract
We developed an apparatus to couple a 50-micrometer diameter whispering-gallery silica microtoroidal resonator in a helium-4 cryostat using a straight optical tapered-fiber at 1550nm wavelength. On a top-loading probe specifically adapted for increased mechanical stability, we use a specifically-developed cryotaper to optically probe the cavity, allowing thus to record the calibrated mechanical spectrum of the optomechanical system at low temperatures. We then demonstrate excellent thermalization of a 63-MHz mechanical mode of a toroidal resonator down to the cryostats base temperature of 1.65K, thereby proving the viability of the cryogenic refrigeration via heat conduction through static low-pressure exchange gas. In the context of optomechanics, we therefore provide a versatile and powerful tool with state-of-the-art performances in optical coupling efficiency, mechanical stability and cryogenic cooling.
We demonstrate adiabatically tapered fibers terminating in sub-micron tips that are clad with a higher-index material for coupling to an on-chip waveguide. This cladding enables coupling to a high-index waveguide without losing light to the buried oxide. A technique to clad the tip of the tapered fiber with a higher-index polymer is introduced. Conventional tapered waveguides and forked tapered waveguide structures are investigated for coupling from the clad fiber to the on-chip waveguide. We find the forked waveguide facilitates alignment and packaging, while the conventional taper leads to higher bandwidth. The insertion loss from a fiber through a forked coupler to a sub-micron silicon nitride waveguide is 1.1 dB and the 3 dB-bandwidth is 90 nm. The coupling loss in the packaged device is 1.3 dB. With a fiber coupled to a conventional tapered waveguide, the loss is 1.4 dB with a 3 dB bandwidth extending beyond the range of the measurement apparatus, estimated to exceed 250 nm.
Vibrating nano- and micromechanical resonators have been the subject of research aiming at ultrasensitive mass sensors for mass spectrometry, chemical analysis and biomedical diagnosis. Unfortunately, their merits diminish dramatically in liquids due to dissipative mechanisms like viscosity and acoustic losses. A push towards faster and lighter miniaturized nanodevices would enable improved performances, provided dissipation was controlled and novel techniques were available to efficiently drive and read-out their minute displacement. Here we report on a nano-optomechanical approach to this problem using miniature semiconductor disks. These devices combine mechanical motion at high frequency above the GHz, ultra-low mass of a few picograms, and moderate dissipation in liquids. We show that high-sensitivity optical measurements allow to direct resolve their thermally driven Brownian vibrations, even in the most dissipative liquids. Thanks to this novel technique, we experimentally, numerically and analytically investigate the interaction of these resonators with arbitrary liquids. Nano-optomechanical disks emerge as probes of rheological information of unprecedented sensitivity and speed, opening applications in sensing and fundamental science.
Electrodes in close proximity to an active area of a device are required for sufficient electrical control. The integration of such electrodes into optical devices can be challenging since low optical losses must be retained to realise high quality operation. Here, we demonstrate that it is possible to place a metallic shallow phosphorus doped layer in a silicon micro-ring cavity that can function at cryogenic temperatures. We verify that the shallow doping layer affects the local refractive index while inducing minimal losses with quality factors up to 10$^5$. This demonstration opens up a pathway to the integration of an electronic device, such as a single-electron transistor, into an optical circuit on the same material platform.
We report on state-of-the-art scanning probe microscopy measurements performed in a pulse tube based top-loading closed-cycle cryostat with a base temperature of 4 K and a 9 T magnet. We decoupled the sample space from the mechanical and acoustic noise from the cryocooling system to enable scanning probe experiments. The extremely low vibration amplitudes in our system enabled successful imaging of 0.39 nm lattice steps on single crystalline SrTiO$_{3}$ as well as magnetic vortices in Bi$_{2}$Sr$_{2}$CaCu$_{2}$O$_{8+x}$ superconductor. Fine control over sample temperature and applied magnetic field further enabled us to probe the helimagnetic and the skyrmion-lattice phases in Fe$_{0.5}$Co$_{0.5}$Si with unprecedented signal-to-noise ratio of 20:1. Finally, we demonstrate for the first time quartz-crystal tuning fork shear-force microscopy in a closed-cycle cryostat.
We cooled ultrathin tapered fibers to cryogenic temperatures and controllably coupled them with high-Q microsphere resonators at a wavelength close to the optical transition of diamond nitrogen vacancy centers. The 310-nm-diameter tapered fibers were stably nanopositioned close to the microspheres with a positioning stability of approximately 10 nm over a temperature range of 7-28 K. A cavity-induced phase shift was observed in this temperature range, demonstrating a discrete transition from undercoupling to overcoupling.