ترغب بنشر مسار تعليمي؟ اضغط هنا

Magnon-Phonon Quantum Correlation Thermometry

238   0   0.0 ( 0 )
 نشر من قبل John Davis
 تاريخ النشر 2020
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

A large fraction of quantum science and technology requires low-temperature environments such as those afforded by dilution refrigerators. In these cryogenic environments, accurate thermometry can be difficult to implement, expensive, and often requires calibration to an external reference. Here, we theoretically propose a primary thermometer based on measurement of a hybrid system consisting of phonons coupled via a magnetostrictive interaction to magnons. Thermometry is based on a cross-correlation measurement in which the spectrum of back-action driven motion is used to scale the thermomechanical motion, providing a direct measurement of the phonon temperature independent of experimental parameters. Combined with a simple low-temperature compatible microwave cavity read-out, this primary thermometer is expected to become a popular thermometer for experiments below 1 K.

قيم البحث

اقرأ أيضاً

We investigate the real-time estimation protocols for the frequency shift of optically detected magnetic resonance (ODMR) of nitrogen-vacancy (NV) centers in nanodiamonds (NDs). Efficiently integrating multipoint ODMR measurements and ND particle tra cking into fluorescence microscopy has recently demonstrated stable monitoring of the temperature inside living animals. We analyze the multipoint ODMR measurement techniques (3-, 4-, and 6-point methods) in detail and quantify the amount of measurement artifact owing to several systematic errors derived from instrumental errors of experimental hardware and ODMR spectral shape. We propose a practical approach to minimize the effect of these factors, which allows for measuring accurate temperatures of single NDs during dynamic thermal events. We also discuss integration of noise filters, data estimation protocols, and possible artifacts for further developments in real-time temperature estimation. The present study provides technical details of quantum diamond thermometry and discusses factors that may affect the temperature estimation in biological applications.
In this study, we analyze the operational process of nanodiamond (ND) quantum thermometry based on wide-field detection of optically detected magnetic resonance (ODMR) of nitrogen vacancy centers, and compare its performance with that of confocal ODM R detection. We found that (1) the thermometry results are significantly affected by the shape and size of the camera region of interest (ROI) surrounding the target NDs and that (2) by properly managing the ROI and acquisition parameters of the camera, a temperature precision comparable to confocal detection in living cells can be obtained by wide-field ODMR. Our results are significant to the development of camera-based real-time large-area quantum thermometry of living cells.
We show how to generate tripartite entanglement in a cavity magnomechanical system which consists of magnons, cavity microwave photons, and phonons. The magnons are embodied by a collective motion of a large number of spins in a macroscopic ferrimagn et, and are driven directly by an electromagnetic field. The cavity photons and magnons are coupled via magnetic dipole interaction, and the magnons and phonons are coupled via magnetostrictive (radiation pressure-like) interaction. We show optimal parameter regimes for achieving the tripartite entanglement where magnons, cavity photons, and phonons are entangled with each other, and we further prove that the steady state of the system is a genuinely tripartite entangled state. The entanglement is robust against temperature. Our results indicate that cavity magnomechanical systems could provide a promising platform for the study of macroscopic quantum phenomena.
The operation of resistive and phase-change memory (RRAM and PCM) is controlled by highly localized self-heating effects, yet detailed studies of their temperature are rare due to challenges of nanoscale thermometry. Here we show that the combination of Raman thermometry and scanning thermal microscopy (SThM) can enable such measurements with high spatial resolution. We report temperature-dependent Raman spectra of HfO$_2$, TiO$_2$ and Ge$_2$Sb$_2$Te$_5$ (GST) films, and demonstrate direct measurements of temperature profiles in lateral PCM devices. Our measurements reveal that electrical and thermal interfaces dominate the operation of such devices, uncovering a thermal boundary resistance of 30 m$^2$K$^{-1}$GW$^{-1}$ at GST-SiO$_2$ interfaces and an effective thermopower 350 $mu$V/K at GST-Pt interfaces. We also discuss possible pathways to apply Raman thermometry and SThM techniques to nanoscale and vertical resistive memory devices.
Color centers in solids are the fundamental constituents of a plethora of applications such as lasers, light emitting diodes and sensors, as well as the foundation of advanced quantum information and communication technologies. Their photoluminescenc e properties are usually studied under Stokes excitation, in which the emitted photons are at a lower energy than the excitation ones. In this work, we explore the opposite Anti-Stokes process, where excitation is performed with lower energy photons. We report that the process is sufficiently efficient to excite even a single quantum system, namely the germanium-vacancy center in diamond. Consequently, we leverage the temperature-dependent, phonon-assisted mechanism to realize an all-optical nanoscale thermometry scheme that outperforms any homologous optical method employed to date. Our results frame a promising approach for exploring fundamental light-matter interactions in isolated quantum systems, and harness it towards the realization of practical nanoscale thermometry and sensing.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا