ترغب بنشر مسار تعليمي؟ اضغط هنا

Bayesian adversarial multi-node bandit for optimal smart grid protection against cyber attacks

101   0   0.0 ( 0 )
 نشر من قبل Huadong Mo
 تاريخ النشر 2021
  مجال البحث الهندسة المعلوماتية
والبحث باللغة English




اسأل ChatGPT حول البحث

The cybersecurity of smart grids has become one of key problems in developing reliable modern power and energy systems. This paper introduces a non-stationary adversarial cost with a variation constraint for smart grids and enables us to investigate the problem of optimal smart grid protection against cyber attacks in a relatively practical scenario. In particular, a Bayesian multi-node bandit (MNB) model with adversarial costs is constructed and a new regret function is defined for this model. An algorithm called Thompson-Hedge algorithm is presented to solve the problem and the superior performance of the proposed algorithm is proven in terms of the convergence rate of the regret function. The applicability of the algorithm to real smart grid scenarios is verified and the performance of the algorithm is also demonstrated by numerical examples.

قيم البحث

اقرأ أيضاً

Modern electric power grid, known as the Smart Grid, has fast transformed the isolated and centrally controlled power system to a fast and massively connected cyber-physical system that benefits from the revolutions happening in the communications an d the fast adoption of Internet of Things devices. While the synergy of a vast number of cyber-physical entities has allowed the Smart Grid to be much more effective and sustainable in meeting the growing global energy challenges, it has also brought with it a large number of vulnerabilities resulting in breaches of data integrity, confidentiality and availability. False data injection (FDI) appears to be among the most critical cyberattacks and has been a focal point interest for both research and industry. To this end, this paper presents a comprehensive review in the recent advances of the defence countermeasures of the FDI attacks in the Smart Grid infrastructure. Relevant existing literature are evaluated and compared in terms of their theoretical and practical significance to the Smart Grid cybersecurity. In conclusion, a range of technical limitations of existing false data attack detection researches are identified, and a number of future research directions are recommended.
False Data Injection (FDI) attacks are a common form of Cyber-attack targetting smart grids. Detection of stealthy FDI attacks is impossible by the current bad data detection systems. Machine learning is one of the alternative methods proposed to det ect FDI attacks. This paper analyzes three various supervised learning techniques, each to be used with three different feature selection (FS) techniques. These methods are tested on the IEEE 14-bus, 57-bus, and 118-bus systems for evaluation of versatility. Accuracy of the classification is used as the main evaluation method for each detection technique. Simulation study clarify the supervised learning combined with heuristic FS methods result in an improved performance of the classification algorithms for FDI attack detection.
Electric power grids are at risk of being compromised by high-impact cyber-security threats such as coordinated, timed attacks. Navigating this new threat landscape requires a deep understanding of the potential risks and complex attack processes in energy information systems, which in turn demands an unmanageable manual effort to timely process a large amount of cross-domain information. To provide an adequate basis to contextually assess and understand the situation of smart grids in case of coordinated cyber-attacks, we need a systematic and coherent approach to identify cyber incidents. In this paper, we present an approach that collects and correlates cross-domain cyber threat information to detect multi-stage cyber-attacks in energy information systems. We investigate the applicability and performance of the presented correlation approach and discuss the results to highlight challenges in domain-specific detection mechanisms.
135 - Xinlei He , Rui Wen , Yixin Wu 2021
Many real-world data comes in the form of graphs, such as social networks and protein structure. To fully utilize the information contained in graph data, a new family of machine learning (ML) models, namely graph neural networks (GNNs), has been int roduced. Previous studies have shown that machine learning models are vulnerable to privacy attacks. However, most of the current efforts concentrate on ML models trained on data from the Euclidean space, like images and texts. On the other hand, privacy risks stemming from GNNs remain largely unstudied. In this paper, we fill the gap by performing the first comprehensive analysis of node-level membership inference attacks against GNNs. We systematically define the threat models and propose three node-level membership inference attacks based on an adversarys background knowledge. Our evaluation on three GNN structures and four benchmark datasets shows that GNNs are vulnerable to node-level membership inference even when the adversary has minimal background knowledge. Besides, we show that graph density and feature similarity have a major impact on the attacks success. We further investigate two defense mechanisms and the empirical results indicate that these defenses can reduce the attack performance but with moderate utility loss.
Cyber-physical attacks impose a significant threat to the smart grid, as the cyber attack makes it difficult to identify the actual damage caused by the physical attack. To defend against such attacks, various inference-based solutions have been prop osed to estimate the states of grid elements (e.g., transmission lines) from measurements outside the attacked area, out of which a few have provided theoretical conditions for guaranteed accuracy. However, these conditions are usually based on the ground truth states and thus not verifiable in practice. To solve this problem, we develop (i) verifiable conditions that can be tested based on only observable information, and (ii) efficient algorithms for verifying the states of links (i.e., transmission lines) within the attacked area based on these conditions. Our numerical evaluations based on the Polish power grid and IEEE 300-bus system demonstrate that the proposed algorithms are highly successful in verifying the states of truly failed links, and can thus greatly help in prioritizing repairs during the recovery process.