The realization and characterization of a high quality factor resonator composed of two hollow-dielectric cylinders with its pseudo-TM$_{030}$ mode resonating at 10.9 GHz frequency is discussed. The quality factor was measured at the temperatures 300 K and 4 K obtaining $mbox{Q}_{300mbox{K}}=(150,000pm 2,000)$ and $mbox{Q}_{4mbox{K}}=(720,000pm 10,000)$respectively, the latter corresponding to a gain of one order of magnitude with respect to a traditional copper cylindrical-cavity with the corresponding TM$_{010}$ mode resonating at the same frequency. The implications to dark-matter axion-searches with cavity experiments are discussed showing that the gain in quality factor is not spoiled by a reduced geometrical coupling $C_{030}$ of the cavity mode to the axion field. This reduction effect is estimated to be at most 20%. Numerical simulations show that frequency tuning of several hundreds MHz is feasible.

قيم البحث

اقرأ أيضاً

Searches for dark matter axion involve the use of microwave resonant cavities operating in a strong magnetic field. Detector sensitivity is directly related to the cavity quality factor, which is limited, however, by the presence of the external magn etic field. In this paper we present a cavity of novel design whose quality factor is not affected by a magnetic field. It is based on a photonic structure by the use of sapphire rods. The quality factor at cryogenic temperature is in excess of $5 times 10^5$ for a selected mode.
We demonstrate a superconducting (SC) microwave (mw) cavity that can accelerate the dark matter search by maintaining superconductivity in a high DC magnetic field. We used high-temperature superconductor (HTSC) yttrium barium copper oxide (YBCO) wit h a phase transition temperature of 90K to prevent SC failure by the magnetic field. Since the direct deposition of HTSC film on the metallic mw cavity is very difficult, we used the commercial HTSC tapes which are flexible metallic tapes coated with HTSC thin films. We fabricated resonating cavity ($f_{TM010}$ ~ 6.89 GHz) with a third of the inner wall covered by YBCO tapes and measured the quality factor (Q factor) at 4K temperature, varying the DC magnetic field from 0 to 8 tesla. There was no significant quality (Q) factor drop and the superconductivity was well maintained even in 8 tesla magnetic field. This implies the possibility of good performance of HTSC mw resonant cavity under a strong magnetic field for axion detection.
The sensitivity of experimental searches for axion dark matter coupled to photons is typically proportional to the strength of the applied static magnetic field. We demonstrate how a permeable material can be used to enhance the magnitude of this sta tic magnetic field, and therefore improve the sensitivity of such searches in the low frequency lumped-circuit limit. Using gadolinium iron garnet toroids at temperature 4.2 K results in a factor of 4 enhancement compared to an air-core toroidal design. The enhancement is limited by magnetic saturation. Correlation of signals from three such toroids allows efficient rejection of systematics due to electromagnetic interference. The sensitivity of a centimeter-scale axion dark matter search based on this approach is on the order of $g_{agammagamma}approx10^{-9}$ GeV$^{-1}$ after 8 hours of data collection for axion masses near $10^{-10}$ eV. This approach may substantially extend the sensitivity reach of large-volume lumped element axion dark matter searches.
271 - Hai-bin Lu , Xiaoping Liu 2017
In this paper, we investigate numerically the trapped modes with near zero group velocities supported in the ring array composed of dielectric nanorods, based on a two-dimensional model. Two sorts of trapped modes in the ring array have been identifi ed: the BCR trapped modes which correspond to the bound modes below the light line at the edge of the first Brillouin zone in the corresponding planar structure (namely the infinite linear chain); the quasi-BIC trapped modes corresponding to the bound states in the continuum supported in the infinite linear chain. According to the whispering gallery condition, the BCR trapped modes can be supported in the ring array only when the number of dielectric elements N is even, while the quasi-BIC ones always exist no matter whether N is odd or even. For both two kind of trapped modes, the lowest one of each kind possesses the highest Q factor, which are ~105 for BCR kind and ~1011 for quasi-BIC kind with N=16 respectively, and the radiation loss increases dramatically as the structural resonance increases. Finally, the behavior of the Q factor with N is explained numerically for the lowest one of each kind of trapped modes. The Q factor scales as Q~exp(0.662N) for the quasi-BIC trapped mode and Q~exp(0.325N) for the BCR one. Intriguingly, the Q factor of the quasi-BIC trapped mode can be as large as ~105 even at N=8. Compared to the finite linear chain, the structure of ring array exhibits overwhelming advantage in Q factor with the same N because there is no array-edge radiation loss in the ring array. We note that the principles can certainly be extended to particles of other shapes (such as nanospheres, nanodisks, and many other experimentally feasible geometries).
Axions and axion-like particles are excellent low-mass dark matter candidates. The MADMAX experiment aims to directly detect galactic axions with masses between $40,mu{rm eV}$ and $400,mu{rm eV}$ by using the axion-induced emission of electromagnetic waves from boundaries between materials of different dielectric constants under a strong magnetic field. Combining many such surfaces, this emission can be significantly enhanced (boosted) using constructive interference and resonances. We present a first proof of principle realization of such a booster system consisting of a copper mirror and up to five sapphire disks. The electromagnetic response of the system is investigated by reflectivity measurements. The mechanical accuracy, calibration process of unwanted reflections and the repeatability of a basic tuning algorithm to place the disks are investigated. We find that for the presented cases the electromagnetic response in terms of the group delay predicted by one-dimensional calculations is sufficiently realized in our setup. The repeatability of the tuning is at the percent level, and would have small impact on the sensitivity of such a booster.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا