Purpose: This is a theoretical simulation study for proof of concept of radiochromic film dosimetry to measure physical and biological doses without plan-based quenching correction for patient-specific quality assurance of carbon-ion radiotherapy. Methods: We took a layer-stacking carbon-ion beam comprised of range-shifted beamlets. The dosimeter response was simulated according to an experimental quenching model. The beam model followed a treatment planning system. The beam was decomposed into finely arranged beamlets with weights estimated by deconvolution of longitudinal dosimeter responses. The distributions of physical and biological doses were reconstructed from the estimated weights, and were compared with the plan. We also evaluated the sensitivity to measurement errors and to erratic delivery with an undelivered beamlet. Results: The reconstructed physical and biological doses accurately reproduced the simulated delivery with errors approximately corresponding to the measurement errors. The erratic beam delivery was easily detectable by comparison of biological dose distribution to the plan. Conclusions: We have developed a method to measure physical and biological doses by longitudinal dosimetry of quenched response without using plan data. The method only involves a general optimization algorithm, a radiobiology model, and experimental beamlet data, and requires no extra corrections. Theoretically, this approach is applicable to various dosimeters and to proton and ion beams of any delivery method, regardless of quenching or biological effectiveness.
In carbon-ion radiotherapy, single-beam delivery each day in alternate directions has been commonly practiced for operational efficiency, taking advantage of the Bragg peak and the relative biological effectiveness (RBE) for uniform dose conformation
Purpose: This study aims to optimize and characterize the response of a mPSD for in vivo dosimetry in HDR brachytherapy. Methods: An exhaustive analysis was carried out in order to obtain an optimized mPSD design that maximize the scintillation light
Depth distributions of positron-emitting nuclei in PMMA phantoms are calculated within a Monte Carlo model for Heavy-Ion Therapy (MCHIT) based on the GEANT4 toolkit (version 8.0). The calculated total production rates of $^{11}$C, $^{10}$C and $^{15}
This article is intended to supplement our 2015 paper in Medical Physics titled Noise properties of CT images reconstructed by use of constrained total-variation, data-discrepancy minimization, in which ordered subsets methods were employed to perfor
MESA (Mainz Energy recovery Superconducting Accelerator) is an energy recovery linac (ERL) which is under construction at Johannes Gutenberg University in Mainz. It will be operated in external beam (EB) mode with 150 $mu$A electron beam at 155 MeV a