ترغب بنشر مسار تعليمي؟ اضغط هنا

Femtometer Displacement Resolution with Phase-Insensitive Doppler Sensing

100   0   0.0 ( 0 )
 نشر من قبل Bethany Little
 تاريخ النشر 2018
  مجال البحث فيزياء
والبحث باللغة English
 تأليف Bethany J. Little




اسأل ChatGPT حول البحث

The measurement of extremely small displacements is of utmost importance, both for fundamental studies [1-4], and practical applications [5-7]. One way to estimate a small displacement is to measure the Doppler shift generated in light reflected off an object moving with a known periodic frequency. This remote sensing technique converts a displacement measurement into a frequency measurement, and has been considerably successful [8-14]. The displacement sensitivity of this technique is limited by the Doppler frequency noise floor and by the velocity of the moving object. Other primary limitations are hours of integration time [12,13] and optimal operation only in a narrow Doppler frequency range. Here we show a sensitive device capable of measuring $mu$Hz/$sqrt{text{Hz}}$ Doppler frequency shifts corresponding to tens of fm displacements for a mirror oscillating at 2 Hz. While the Doppler shift measured is comparable to other techniques [12.13], the position sensitivity is orders of magnitude better, and operates over several orders of magnitude of Doppler frequency range. In addition, unlike other techniques which often rely on interferometric methods, our device is phase insensitive, making it unusually robust to noise.

قيم البحث

اقرأ أيضاً

A photonic force microscope comprises of an optically trapped micro-probe and a position detection system to track the motion of the probe. Signal collection for motion detection is often carried out using the backscattered light off the probe - howe ver, this mode has problems of low S/N due to the small back-scattering cross-sections of the micro-probes typically used. The position sensors often used in these cases are quadrant photodetectors. To ensure maximum sensitivity of such detectors, it would help if the detector size matched with the detection beam radius after the condenser lens (which for backscattered detection would be the trapping objective itself). To suit this condition, we have used a miniature displacement sensor whose dimensions makes it ideal to work with 1:1 images of micron-sized trapped probes in the back-scattering detection mode. The detector is based on the quadrant photo-IC in the optical pick-up head of a compact disc player. Using this detector, we measured absolute displacements of an optically trapped 1.1 um probe with a resolution of ~10 nm for a bandwidth of 10 Hz at 95% significance without any sample or laser stabilization. We characterized our optical trap for different sized probes by measuring the power spectrum for each probe to 1% accuracy, and found that for 1.1 um diameter probes, the noise in our position measurement matched the thermal resolution limit for averaging times up to 10 ms. We also achieved a linear response range of around 385 nm with crosstalk between axes ~4% for 1.1 um diameter probes. The detector has extremely high bandwidth (few MHz) and low optical power threshold - other factors that can lead to its widespread use in photonic force microscopy.
Miniaturized mechanical resonators have proven to be excellent force sensors. However, they usually rely on resonant sensing schemes, and their excellent performance cannot be utilized for the detection of static forces. Here, we report on a novel st atic-force sensing scheme and demonstrate it using optically levitated nanoparticles in vacuum. Our technique relies on an off-resonant interaction of the particle with a weak static force, and a resonant read-out of the displacement caused by this interaction. We demonstrate a force sensitivity of $10,mathrm{aN}$ to static gravitational and electric forces acting on the particle. Our work not only provides a tool for the closer investigation of short-range forces, but also marks an important step towards the realization of matter-wave interferometry with macroscopic objects.
Using weak values amplification angular resolution limits, we theoretically investigate the gravitational sensing of objects. By inserting a force-sensing pendulum into a weak values interferometer, the optical response can sense accelerations to a f ew 10s of $mathrm{zepto}text{-}mathrm{g}/sqrt{mathrm{Hz}}$, with optical powers of $1~mathrm{mW}$. We convert this precision into range and mass sensitivity, focusing in detail on simple and torsion pendula. Various noise sources present are discussed, as well as the necessary cooling that should be applied to reach the desired levels of precision.
Dual-comb spectroscopy has emerged as an indispensable analytical technique in applications that require high resolution and broadband coverage within short acquisition times. Its experimental realization, however, remains hampered by intricate exper imental setups with large power consumption. Here, we demonstrate an ultra-simple free-running dual-comb spectrometer realized in a single all-fiber cavity suitable for the most demanding Doppler-limited measurements. Our dual-comb laser utilizes just a few basic fiber components, allows to tailor the repetition rate difference, and requires only 350 mW of electrical power for sustained operation over a dozen of hours. As a demonstration, we measure low-pressure hydrogen cyanide within 1.7 THz bandwidth, and obtain better than 1% precision over a terahertz in 200 ms enabled by a drastically simplified all-computational phase correction algorithm. The combination of the unprecedented setup simplicity, comb tooth resolution and high spectroscopic precision paves the way for proliferation of frequency comb spectroscopy even outside the laboratory.
105 - C. J. Edgcombe 2013
Analysis of the imaging of some simple distributions of object phase by a phase plate of Zernike type shows that sharp transitions in the object phase are well transmitted. The low-frequency components of the complete object function are attenuated b y the plate. The behaviour can be characterised by a cut-on parameter defined as the product of the cut-on frequency of the plate and a characteristic dimension of the object. When this parameter exceeds a value of the order of unity, a sharp boundary in the object is imaged by a Zernike plate as a dark lining inside the boundary with a white outline or halo outside the boundary, in agreement with reported observations. The maximum diameter of objects that can be imaged accurately is inversely proportional to the diameter of the hole for beam transmission in the phase plate.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا