Static capacitive pressure sensing using a single graphene drum

83   0   0.0 ( 0 )
 نشر من قبل Dejan Davidovikj
 تاريخ النشر 2017
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

To realize nanomechanical graphene-based pressure and gas sensors, it is beneficial to have a method to electrically readout the static displacement of a suspended graphene membrane. Capacitive readout, typical in micro-electro-mechanical systems (MEMS), gets increasingly challenging as one starts shrinking the dimensions of these devices, since the expected responsivity of such devices is below 0.1 aF/Pa. To overcome the challenges of detecting small capacitance changes, we design an electrical readout device fabricated on top of an insulating quartz substrate, maximizing the contribution of the suspended membrane to the total capacitance of the device. The capacitance of the drum is further increased by reducing the gap size to 110 nm. Using external pressure load, we demonstrate successful detection of capacitance changes of a single graphene drum down to 50 aF, and pressure differences down to 25 mbar.

قيم البحث

اقرأ أيضاً

The high flexibility, impermeability and strength of graphene membranes are key properties that can enable the next generation of nanomechanical sensors. However, for capacitive pressure sensors the sensitivity offered by a single suspended graphene membrane is too small to compete with commercial sensors. Here, we realize highly sensitive capacitive pressure sensors consisting of arrays of nearly ten thousand small, freestanding double-layer graphene membranes. We fabricate large arrays of small diameter membranes using a procedure that maintains the superior material and mechanical properties of graphene, even after high-temperature anneals. These sensors are readout using a low cost battery-powered circuit board, with a responsivity of up to 47.8 aF Pa$^{-1}$ mm$^{-2}$, thereby outperforming commercial sensors.
Developing fast, accurate and scalable techniques for quantum state readout is an active area in semiconductor-based quantum computing. Here, we present results on dispersive sensing of silicon corner state quantum dots coupled to lumped-element elec trical resonators via the gate. The gate capacitance of the quantum device is configured in parallel with a superconducting spiral inductor resulting in resonators with loaded Q-factors in the 400-800 range. For a resonator operating at 330 MHz, we achieve a charge sensitivity of 7.7 $mu$e$/sqrt{text{Hz}}$ and, when operating at 616 MHz, we get 1.3 $mu$e$/sqrt{text{Hz}}$. We perform a parametric study of the resonator to reveal its optimal operation points and perform a circuit analysis to determine the best resonator design. The results place gate-based sensing at par with the best reported radio-frequency single-electron transistor sensitivities while providing a fast and compact method for quantum state readout.
67 - Sanjin J. Gutic 2018
Increasing energy demands of modern society requires deep understanding of the properties of energy storage materials as well as their performance tuning. We show that the capacitance of graphene oxide (GO) can be precisely tuned using a simple elect rochemical reduction route. In situ resistance measurements, combined with cyclic voltammetry measurement and Raman spectroscopy, have shown that upon the reduction GO is irreversibly deoxygenated which is further accompanied with structural ordering and increasing of electrical conductivity. The capacitance is maximized when the concentration of oxygen functional groups is properly balanced with the conductivity. Any further reduction and de-oxygenation leads to the gradual loss of the capacitance. The observed trend is independent on the preparation route and on the exact chemical and structural properties of GO. It is proposed that an improvement of capacitive properties of any GO can be achieved by optimization of its reduction conditions.
Over the past decade, capacitive deionization (CDI) has realized a surge in attention in the field of water desalination and can now be considered as an important technology class, along with reverse osmosis and electrodialysis. While many of the rec ently developed technologies no longer use a mechanism that follows the strict definition of the term capacitive, these methods nevertheless share many common elements that encourage treating them with similar metrics and analyses. Specifically, they all involve electrically driven removal of ions from a feed stream, storage in an electrode (i.e., ion electrosorption) and release, in charge/discharge cycles. Grouping all these methods in the technology class of CDI makes it possible to treat evolving new technologies in standardized terms and compare them to other technologies in the same class.
On-chip temperature sensing on a micro- to nanometer scale is becoming more desirable as the complexity of nanodevices and size requirements increase and with it the challenges in thermal probing and management. This highlights the need for scalable and reliable temperature sensors which have the potential to be incorporated into current and future device structures. Here, we show that U-shaped graphene stripes consisting of one wide and one narrow leg form a single material thermocouple that can function as a self-powering temperature sensor. We find that the graphene thermocouples increase in sensitivity with a decrease in leg width, due to a change in the Seebeck coefficient, which is in agreement with our previous findings and report a maximum sensitivity of $Delta S approx$ 39 $mathrm{mu}$V/K.