ترغب بنشر مسار تعليمي؟ اضغط هنا

Modal noise in an integrated photonic lantern fed diffraction-limited spectrograph

79   0   0.0 ( 0 )
 نشر من قبل Nick Cvetojevic
 تاريخ النشر 2017
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

In an attempt to develop a streamlined astrophotonic instrument, we demonstrate the realization of an all-photonic device capable of both multimode to single mode conversion and spectral dispersion on an 8-m class telescope with efficient coupling. The device was a monolithic photonic spectrograph which combined an integrated photonic lantern, and an efficient arrayed waveguide grating device. During on-sky testing, we discovered a previously unreported type of noise that made spectral extraction and calibration extremely difficult. The source of the noise was traced to a wavelength-dependent loss mechanism between the feed fibers multimode near-field pattern, and the modal acceptance profile of the integrated photonic lantern. Extensive modeling of the photonic components replicates the wavelength-dependent loss, and demonstrates an identical effect on the final spectral output. We outline that this could be mitigated by directly injecting into the integrated photonic lantern.

قيم البحث

اقرأ أيضاً

Celestially, Positronium (Ps), has only been observed through gamma-ray emission produced by its annihilation. However, in its triplet state, a Ps atom has a mean lifetime long enough for electronic transitions to occur between quantum states. This p roduces a recombination spectrum observable in principle at near IR wavelengths, where angular resolution greatly exceeding that of the gamma-ray observations is possible. However, the background in the NIR is dominated by extremely bright atmospheric hydroxyl (OH) emission lines. In this paper we present the design of a diffraction-limited spectroscopic system using novel photonic components - a photonic lantern, OH Fiber Bragg Grating filters, and a photonic TIGER 2-dimensional pseudo-slit - to observe the Ps Balmer alpha line at 1.3122 microns for the first time.
We demonstrate a new approach to classical fiber-fed spectroscopy. Our method is to use a photonic lantern that converts an arbitrary (e.g. incoherent) input beam into N diffraction-limited outputs. For the highest throughput, the number of outputs m ust be matched to the total number of unpolarized spatial modes on input. This approach has many advantages: (i) after the lantern, the instrument is constructed from commercial off the shelf components; (ii) the instrument is the minimum size and mass configuration at a fixed resolving power and spectral order (~shoebox sized in this case); (iii) the throughput is better than 60% (slit to detector, including detector QE of ~80%); (iv) the scattered light at the detector can be less than 0.1% (total power). Our first implementation operates over 1545-1555 nm (limited by the detector, a 640$times$512 array with 20$mu$m pitch) with a spectral resolution of 0.055nm (R~30,000) using a 1$times$7 (1 multi-mode input to 7 single-mode outputs) photonic lantern. This approach is a first step towards a fully integrated, multimode photonic microspectrograph.
The coupling of large telescopes to astronomical instruments has historically been challenging due to the tension between instrument throughput and stability. Light from the telescope can either be injected wholesale into the instrument, maintaining high throughput at the cost of point-spread function (PSF) stability, or the time-varying components of the light can be filtered out with single-mode fibers (SMFs), maintaining instrument stability at the cost of light loss. Today, the field of astrophotonics provides a potential resolution to the throughput-stability tension in the form of the photonic lantern (PL): a tapered waveguide which can couple a time-varying and aberrated PSF into multiple diffraction-limited beams at an efficiency that greatly surpasses direct SMF injection. As a result, lantern-fed instruments retain the stability of SMF-fed instruments while increasing their throughput. To this end, we present a series of numerical simulations characterizing PL performance as a function of lantern geometry, wavelength, and wavefront error (WFE), aimed at guiding the design of future diffraction-limited spectrometers. These characterizations include a first look at the interaction between PLs and phase-induced amplitude apodization (PIAA) optics.
We present here CAFE, the Calar Alto Fiber-fed Echelle spectrograph, a new instrument built at the Centro Astronomico Hispano Aleman (CAHA). CAFE is a single fiber, high-resolution ($Rsim$70000) spectrograph, covering the wavelength range between 365 0-9800AA. It was built on the basis of the common design for Echelle spectrographs. Its main aim is to measure radial velocities of stellar objects up to $Vsim$13-14 mag with a precision as good as a few tens of $m s^{-1}$. To achieve this goal the design was simplified at maximum, removing all possible movable components, the central wavelength is fixed, so the wavelentgth coverage; no filter wheel, one slit and so on, with a particular care taken in the thermal and mechanical stability. The instrument is fully operational and publically accessible at the 2.2m telescope of the Calar Alto Observatory. In this article we describe (i) the design, summarizing its manufacturing phase; (ii) characterize the main properties of the instrument; (iii) describe the reduction pipeline; and (iv) show the results from the first light and commissioning runs. The preliminar results indicate that the instrument fulfill the specifications and it can achieve the foreseen goals. In particular, they show that the instrument is more efficient than anticipated, reaching a $S/Nsim$20 for a stellar object as faint as $Vsim$14.5 mag in $sim$2700s integration time. The instrument is a wonderful machine for exoplanetary research (by studying large samples of possible systems cotaining massive planets), galactic dynamics (high precise radial velocities in moving groups or stellar associations) or astrochemistry.
The PolyOculus technology produces large-area-equivalent telescopes by using fiber optics to link modules of multiple semi-autonomous, small, inexpensive, commercial-off-the-shelf telescopes. Crucially, this scalable design has construction costs whi ch are > 10x lower than equivalent traditional large-area telescopes. We have developed a novel photonic lantern approach for the PolyOculus fiber optic linkages which potentially offers substantial advantages over previously considered free-space optical linkages, including much higher coupling efficiencies. We have carried out the first laboratory tests of a photonic lantern prototype developed for PolyOculus, and demonstrate broadband efficiencies of ~91%, confirming the outstanding performance of this technology.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا