ترغب بنشر مسار تعليمي؟ اضغط هنا

Decomposition of the absorbed dose by LET in tissue-equivalent materials within the SHIELD-HIT transport code

42   0   0.0 ( 0 )
 نشر من قبل Riza Ogul
 تاريخ النشر 2015
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

The SHIELD-HIT transport code, in sever



قيم البحث

اقرأ أيضاً

In this article, a new method for the reconstruction of hit-position and hit-time of photons in long scintillator detectors is investigated. This research is motivated by the recent development of the positron emission tomography scanners based on pl astic scintillators. The proposed method constitutes a new way of signal processing in Multi-Voltage-Technique. It is based on the determination of the degree of similarity between the registered signals and the synchronized model signals stored in a library. The library was established for a set of well defined hit-positions along the length of the scintillator. The Mahalanobis distance was used as a measure of similarity between the two compared signals. The method was validated on the experimental data measured using two-strips J-PET prototype with dimensions of 5x9x300 mm$^3$. The obtained Time-of-Flight (TOF) and spatial resolutions amount to 325~ps (FWHM) and 25~mm (FWHM), respectively. The TOF resolution was also compared to the results of an analogous study done using Linear Fitting method. The best TOF resolution was obtained with this method at four pre-defined threshold levels which was comparable to the resolution achieved from the Mahalanobis distance at two pre-defined threshold levels. Although the algorithm of Linear Fitting method is much simpler to apply than the Mahalanobis method, the application of the Mahalanobis distance requires a lower number of applied threshold levels and, hence, decreases the costs of electronics used in PET scanner.
Characterization of microstructures in live tissues is one of the keys to diagnosing early stages of pathology and understanding disease mechanisms. However, the extraction of reliable information on biomarkers based on microstructure details is stil l a challenge, as the size of features that can be resolved with non-invasive Magnetic Resonance Imaging (MRI) is orders of magnitude larger than the relevant structures. Here we derive from quantum information theory the ultimate precision limits for obtaining such details by MRI probing of water-molecule diffusion. We show that already available MRI pulse sequences can be optimized to attain the ultimate precision limits by choosing control parameters that are uniquely determined by the expected size, the diffusion coefficient and the spin relaxation time $T_{2}$. By attaining the ultimate precision limit per measurement, the number of measurements and the total acquisition time may be drastically reduced compared to the present state of the art. These results will therefore allow MRI to advance towards unravelling a wealth of diagnostic information.
Sleep loss has been linked to heart disease, diabetes, cancer, and an increase in accidents, all of which are among the leading causes of death in the United States. Population-scale sleep studies have the potential to advance public health by helpin g to identify at-risk populations, changes in collective sleep patterns, and to inform policy change. Prior research suggests other kinds of health indicators such as depression and obesity can be estimated using social media activity. However, the inability to effectively measure collective sleep with publicly available data has limited large-scale academic studies. Here, we investigate the passive estimation of sleep loss through a proxy analysis of Twitter activity profiles. We use Spring Forward events, which occur at the beginning of Daylight Savings Time in the United States, as a natural experimental condition to estimate spatial differences in sleep loss across the United States. On average, peak Twitter activity occurs roughly 45 minutes later on the Sunday following Spring Forward. By Monday morning however, activity curves are realigned with the week before, suggesting that at least on Twitter, the lost hour of early Sunday morning has been quickly absorbed.
By extending the dynamical coupled-channels analysis performed in our previous work [Phys. Rev. C 88, 035209 (2013)] to include the available data of photoproduction of pi meson off the neutron, the transition amplitudes for the photo-excitation of t he neutron to nucleon resonances, gamma n --> N*, at the resonance pole positions are determined. The combined fits to the data for both the proton- and neutron-target reactions also revise our results for the resonance pole positions and the gamma p --> N* transition amplitudes. Our results allow an isospin decomposition of the gamma N --> N* transition amplitudes for the isospin I=1/2 N* resonances, which is necessary for testing hadron structure models and gives crucial inputs for constructing models of neutrino-induced reactions in the nucleon resonance region.
233 - Li-Gang Wang 2008
In this paper, we present the equivalent medium theory by using the linear response theory. It is found that, under the condition of the linear response, a series of different media with different refractive indices $n_{i}(omega)$ and lengths $d_{i}$ can be equivalent to an effective medium with the volume-averaged refractive index $frac{1}{D}sum_{i=1}^{N}n_{i}(omega)d_{i}$ and the total length $D=sum_{i=1i}^{N}d_{i}$,where $N$ is the number of different media. Based on this equivalent theory, it is a simple but very useful method to design the effective medium with any desirable dispersion properties. As an example, we present a proposal to obtain the enhancement or reduction of the refractive index without absorption and the large dispersion without obvious absorption by assembling different linear dispersive gain and absorptive media.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا