ترغب بنشر مسار تعليمي؟ اضغط هنا

Phase Aberrations in Diffraction Microscopy

67   0   0.0 ( 0 )
 نشر من قبل Stefano Marchesini
 تاريخ النشر 2005
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

In coherent X-ray diffraction microscopy the diffraction pattern generated by a sample illuminated with coherent x-rays is recorded, and a computer algorithm recovers the unmeasured phases to synthesize an image. By avoiding the use of a lens the resolution is limited, in principle, only by the largest scattering angles recorded. However, the imaging task is shifted from the experiment to the computer, and the algorithms ability to recover meaningful images in the presence of noise and limited prior knowledge may produce aberrations in the reconstructed image. We analyze the low order aberrations produced by our phase retrieval algorithms. We present two methods to improve the accuracy and stability of reconstructions.

قيم البحث

اقرأ أيضاً

Interferometric scattering (iSCAT) microscopy is an emerging label-free technique optimized for the sensitive detection of nano-matter. Previous iSCAT studies have approximated the point spread function in iSCAT by a Gaussian intensity distribution. However, recent efforts to track the mobility of nanoparticles in challenging speckle environments and over extended axial ranges has necessitated a quantitative description of the interferometric point spread function (iPSF). We present a robust vectorial diffraction model for the iPSF in tandem with experimental measurements and rigorous FDTD simulations. We examine the iPSF under various imaging scenarios to understand how aberrations due to the experimental configuration encode information about the nanoparticle. We show that the lateral shape of the iPSF can be used to achieve nanometric three-dimensional localization over an extended axial range on the order of 10$,mu$m either by means of a fit to an analytical model or calibration-free unsupervised machine learning. Our results have immediate implications for three-dimensional single particle tracking in complex scattering media.
Coherent X-ray diffraction microscopy is a method of imaging non-periodic isolated objects at resolutions only limited, in principle, by the largest scattering angles recorded. We demonstrate X-ray diffraction imaging with high resolution in all thre e dimensions, as determined by a quantitative analysis of the reconstructed volume images. These images are retrieved from the 3D diffraction data using no a priori knowledge about the shape or composition of the object, which has never before been demonstrated on a non-periodic object. We also construct 2D images of thick objects with infinite depth of focus (without loss of transverse spatial resolution). These methods can be used to image biological and materials science samples at high resolution using X-ray undulator radiation, and establishes the techniques to be used in atomic-resolution ultrafast imaging at X-ray free-electron laser sources.
103 - D. Schurig , D.R. Smith 2004
We examine the Seidel aberrations of thin spherical lenses composed of media with refractive index not restricted to be positive. We find that consideration of this expanded parameter space allows reduction or elimination of more aberrations than is possible with only positive index media. In particular we find that spherical lenses possessing real aplanatic focal points are possible only with negative index. We perform ray tracing, using custom code that relies only on Maxwells equations and conservation of energy, that confirms the results of the aberration calculations.
341 - Azeem Ahmad , Nikhil Jayakumar , 2021
Quantitative phase microscopy (QPM) has found significant applications in the field of biomedical imaging which works on the principle of interferometry. The theory behind achieving interference in QPM with conventional light sources such as white li ght and lasers is very well developed. Recently, the use of dynamic speckle illumination (DSI) in QPM has attracted attention due to its advantages over conventional light sources such as high spatial phase sensitivity, single shot, scalable field of view (FOV) and resolution. However, the understanding behind obtaining interference fringes in QPM with DSI has not been convincingly covered previously. This imposes a constraint on obtaining interference fringes in QPM using DSI and limits its widespread penetration in the field of biomedical imaging. The present article provides the basic understanding of DSI through both simulation and experiments that is essential to build interference optical microscopy systems such as QPM, digital holographic microscopy and optical coherence tomography. Using the developed theory of DSI we demonstrate its capabilities of using non-identical objective lenses in both arms of the interference microscopy without degrading the interference fringe contrast and providing the flexibility to use user-defined microscope objective lens. It is also demonstrated that the interference fringes are not washed out over a large range of optical path difference (OPD) between the object and the reference arm providing competitive edge over low temporal coherence light sources. The theory and explanation developed here would enable wider penetration of DSI based QPM for applications in biology and material sciences.
We experimentally characterize the positions of the diffraction maxima of a phase grating on a screen, for laser light at oblique incidence (so-called off-plane diffraction or conical diffraction). We discuss the general case of off-plane diffraction geometries and derive basic equations for the positions of the diffraction maxima, in particular for their angular dependence. In contrast to previously reported work [Jetty et al., Am. J. Phys. 80, 972 (2012)], our reasoning is solely based on energy- and momentum conservation. We find good agreement of our theoretical prediction with the experiment. A detailed discussion of the diffraction maxima positions, the number of diffraction orders, and the diffraction efficiencies is provided. We assess the feasibility of an experimental test of the phenomenon for neutron matter waves.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا