ترغب بنشر مسار تعليمي؟ اضغط هنا

Sporadic electron jets from cathodes - The main breakdown-triggering mechanism in gaseous detectors

69   0   0.0 ( 0 )
 نشر من قبل Janina Ostling
 تاريخ النشر 2001
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

We have demonstrated experimentally that the main breakdown-triggering mechanism in most gaseous detectors, including micropattern gaseous detectors, is sporadic electron jets from the cathode surfaces. Depending on conditions, each jet contains randomly from a few primary electrons up to 10^5, emitted in a time interval ranging between 0.1 microsecond to milliseconds. After the emission, these primary electrons experience a full gas multiplication in the detector and create spurious pulses. The rate of these jets increases with applied voltage and very sharply at voltages close to the breakdown limit. We found that these jets are in our measurements responsible for the breakdown-triggering at any counting rate between 10^(-2) Hz/mm^2 and 10^8 Hz/mm^2. We demonstrated on a few detectors that an optimized cathode-geometry, a high electrode surface quality and a proper choice of the gas mixture, considerably improve the performance characteristics and provide the highest possible gains.

قيم البحث

اقرأ أيضاً

Currently a revolution is happening in the development of gaseous detectors of photons and particles. Recently developed gaseous detectors with solid photocathodes are now replacing photosensitive wire chambers, which dominated for years in high ener gy and space flight experiments. We will review the main developments in this field as well as their applications in high-energy physics, medicine, industry and plasma diagnostics. New results on solid photocathodes coupled with gaseous micropattern/wire detectors will also be presented.
143 - T. Francke , V. Peskov 2004
Currently a revolution is taking place in the development of gaseous detectors of photons and particles. Parallel plate-type and wire-type detectors which dominated for years in high energy and space flight experiments are now being replaced by recen tly invented Micropattern gaseous detectors. We will now review the main achievements in this field and discuss the most promising directions in future developments and applications.
The operation principle and preliminary results of a novel gas-avalanche patterned hole electron multiplier, the Thick-COBRA (THCOBRA), are presented. This micro-hole structure is derived from the THGEM and MHSP. Sub-millimeter diameter holes are mec hanically drilled in a thin G10 plate, Cu-clad on both faces; on one of the faces the Cu is etched to produce additional anode strips winding between circular cathode strips. Primary avalanches occurring within the holes are followed by additional ones at the anode-strips vicinity. Gains in excess of 5*104 were reached with 22.1 x-rays in Ar, Ne and Ar-10%CH4, with 12.2 % FWHM energy resolution in Ar-10%CH4. Higher gains were measured with single photoelectrons. This robust multiplier may have numerous potential applications.
121 - Maxim Titov 2010
Since long time, the compelling scientific goals of future high energy physics experiments were a driving factor in the development of advanced detector technologies. A true innovation in detector instrumentation concepts came in 1968, with the devel opment of a fully parallel readout for a large array of sensing elements - the Multiwire Proportional Chamber (MWPC), which earned Georges Charpak a Nobel prize in physics in 1992. Since that time radiation detection and imaging with fast gaseous detectors, capable of economically covering large detection volume with low mass budget, have been playing an important role in many fields of physics. Advances in photo-lithography and micro-processing techniques in the chip industry during the past decade triggered a major transition in the field of gas detectors from wire structures to Micro-Pattern Gas Detector (MPGD) concepts, revolutionizing cell size limitations for many gas detector applications. The high radiation resistance and excellent spatial and time resolution make them an invaluable tool to confront future detector challenges at the next generation of colliders. The design of the new micro-pattern devices appears suitable for industrial production. Novel structures where MPGDs are directly coupled to the CMOS pixel readout represent an exciting field allowing timing and charge measurements as well as precise spatial information in 3D. Originally developed for the high energy physics, MPGD applications has expanded to nuclear physics, UV and visible photon detection, astroparticle and neutrino physics, neutron detection and medical physics.
We have studied gain vs. voltage characteristics and position resolutions of multistep capillary plates (two or three capillary plates operating in a cascade), as well as capillary plates operating in a mode when the main amplification occurs between plates or between the capillary plate and the readout plate (parallel plate amplification mode). Results of these studies demonstrated that in the parallel-plate amplification mode one can reach both high gains (>100000) and good position resolutions (~100 micro meter) even with a single step arrangement. It offers a compact amplification structure, which can be used in many applications. For example, in preliminary tests we succeeded to combine it with a photocathode and use it as a position sensitive gaseous photomultiplier. CsI coated capillary plates could also be used as a high position resolution and high rate X-ray converter.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا