Currently a revolution is taking place in the development of gaseous detectors of photons and particles. Parallel plate-type and wire-type detectors which dominated for years in high energy and space flight experiments are now being replaced by recently invented Micropattern gaseous detectors. We will now review the main achievements in this field and discuss the most promising directions in future developments and applications.



قيم البحث

اقرأ أيضاً

Electroluminescence produced during avalanche development in gaseous avalanche detectors is an useful information for triggering, calorimetry and tracking in gaseous detectors. Noble gases present high electroluminescence yields, emitting mainly in t he VUV region. The photons can provide signal readout if appropriate photosensors are used. Micropattern gaseous detectors are good candidates for signal amplification in high background and/or low rate experiments due to their high electroluminescence yields and radiopurity. In this work, the VUV light responses of the Gas Electron Multiplier and of the Micro-Hole Strip Plate, working with pure xenon, are simulated and studied in detail using a new and versatile C++ toolkit. It is shown that the solid angle subtended by a photosensor placed below the microstructures depends on the operating conditions. The obtained absolute EL yields, determined for different gas pressures and as functions of the applied voltage, are compared with those determined experimentally.
We performed a new series of systematic studies of gain and rate characteristics of several micropattern gaseous detectors. Extending earlier studies, these measurements were done at various pressures, gas mixtures, at a wide range of primary charges and also when the whole area of the detectors was irradiated with a high intensity x-ray beam. Several new effects were discovered, common to all tested detectors, which define fundamental limits of operation. The results of these studies allow us to identify several concrete ways of improving the performance of micropattern detectors and to suggest that in some applications RPCs may constitute a valid alternative. Being protected from damaging discharges by the resistive electrodes, these detectors feature high gain, high rate capability (10^5 Hz/mm^2), good position resolution (better than 30 micrometer) and excellent timing (50 ps sigma).
The paper summarizes our latest progress in the development of newly introduced micro pattern gaseous detectors with resistive electrodes. These resistive electrodes protect the detector and the front-end electronics in case of occasional discharges and thus make the detectors very robust and reliable in operation. As an example, we describe in greater detail a new recently developed GEM-like detector, fully spark-protected with electrodes made of resistive kapton. We discovered that all resistive layers used in these studies (including kapton), that are coated with photosensitive layers, such as CsI, can be used as efficient photo cathodes for detectors operating in a pulse counting mode. We describe the first applications of such detectors combined with CsI or SbCs photo cathodes for the detection of UV photons at room and cryogenic temperatures.
180 - V. Peskov , A.Di Mauroa , P. Fonte 2013
We have developed a cost effective technology for manufacturing various layouts of micropattern gaseous detectors for a wide range of applications. Such devices feature resistive electrodes interfaced to a network of thin readout strips/electrodes. T he following three examples of such innovative designs and their applications will be presented: a prototype of a novel double-phase LAr detector with a CsI photocathode immersed inside the LAr, a CsI-RICH detector prototype for ALICE upgrade and GEM-like sensors for environmental safety/security applications.
Identification of high momentum hadrons at the future EIC is crucial, gaseous RICH detectors are therefore viable option. Compact collider setups impose to construct RICHes with small radiator length, hence significantly limiting the number of detect ed photons. More photons can be detected in the far UV region, using a windowless RICH approach. QE of CsI degrades under strong irradiation and air contamination. Nanodiamond based photocathodes (PCs) are being developed as an alternative to CsI. Recent development of layers of hydrogenated nanodiamond powders as an alternative photosensitive material and their performance, when coupled to the THick Gaseous Electron Multipliers (THGEM)-based detectors, are the objects of an ongoing R&D. We report about the initial phase of our studies.