ترغب بنشر مسار تعليمي؟ اضغط هنا

Calibration of the Spectrometer aboard the INTEGRAL satellite

58   0   0.0 ( 0 )
 نشر من قبل St\\'ephane Schanne
 تاريخ النشر 2003
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

SPI, the Spectrometer on board the ESA INTEGRAL satellite, to be launched in October 2002, will study the gamma-ray sky in the 20 keV to 8 MeV energy band with a spectral resolution of 2 keV for photons of 1 MeV, thanks to its 19 germanium detectors spanning an active area of 500 cm2. A coded mask imaging technique provides a 2 deg angular resolution. The 16 deg field of view is defined by an active BGO veto shield, furthermore used for background rejection. In April 2001 the flight model of SPI underwent a one-month calibration campaign at CEA in Bruy`eres le Ch^atel using low intensity radioactive sources and the CEA accelerator for homogeneity measurements and high intensity radioactive sources for imaging performance measurements. After integration of all scientific payloads (the spectrometer SPI, the imager IBIS and the monitors JEM-X and OMC) on the INTEGRAL satellite, a cross-calibration campaign has been performed at the ESA center in Noordwijk. A set of sources has been placed in the field of view of the different instruments in order to compare their performances and determine their mutual influence. Some of those sources had already been used in Bruy`eres during the SPI standalone test. For the lowest energy band calibration an X-ray generator has been used. We report on the scientific goals of this calibration activity, and present the measurements performed as well as some preliminary results.


قيم البحث

اقرأ أيضاً

90 - S. McGlynn 2007
The spectrometer aboard INTEGRAL, SPI, has the capability to detect the signature of polarised emission from a bright gamma-ray source. GRB 041219a is the most intense burst localised by INTEGRAL and is an ideal candidate for such a study. Polarisati on can be measured using multiple events scattered into adjacent detectors because the Compton scatter angle depends on the polarisation of the incoming photon. A search for linear polarisation in the most intense pulse of duration 66 seconds and in the brightest 12 seconds of GRB 041219a was performed in the 100-350keV, 100-500keV and 100keV-1MeV energy ranges. The multiple event data from the spectrometer was analysed and compared with the predicted instrument response obtained from Monte-Carlo simulations using the GEANT 4 INTEGRAL mass model. The chi^2 distribution between the real and simulated data as a function of the percentage polarisation and polarisation angle was calculated for all three energy ranges. The degree of linear polarisation in the brightest pulse of duration 66s was found to be 63+/-31% at an angle of 70+/-14 degrees in the 100-350keV energy range. The degree of polarisation was also constrained in the brightest 12s of the GRB and a polarisation fraction of 96+/-40% at an angle of 60+/-14 degrees was determined over the same energy range. However, despite extensive analysis and simulations, a systematic effect that could mimic the weak polarisation signal could not be definitively excluded. Our results over several energy ranges and time intervals are consistent with a polarisation signal of about 60% at a low level of significance (2 sigma). We conclude that the procedure described here demonstrates the effectiveness of using SPI as a polarimeter, and is a viable method of measuring polarisation levels in intense gamma--ray bursts.
Fast timing capability in X-ray observation of astrophysical objects is one of the key properties for the ASTRO-H (Hitomi) mission. Absolute timing accuracies of 350 micro second or 35 micro second are required to achieve nominal scientific goals or to study fast variabilities of specific sources. The satellite carries a GPS receiver to obtain accurate time information, which is distributed from the central onboard computer through the large and complex SpaceWire network. The details on the time system on the hardware and software design are described. In the distribution of the time information, the propagation delays and jitters affect the timing accuracy. Six other items identified within the timing system will also contribute to absolute time error. These error items have been measured and checked on ground to ensure the time error budgets meet the mission requirements. The overall timing performance in combination with hardware performance, software algorithm, and the orbital determination accuracies, etc, under nominal conditions satisfies the mission requirements of 35 micro second. This work demonstrates key points for space-use instruments in hardware and software designs and calibration measurements for fine timing accuracy on the order of microseconds for mid-sized satellites using the SpaceWire (IEEE1355) network.
The radio as well as the high energy emission mechanism in pulsars is yet not understood properly. A multi-wavelength study is likely to help in better understanding of such processes. The first Indian space-based observatory, ASTROSAT, has five inst ruments aboard, which cover the electromagnetic spectrum from infra-red (1300 $AA$) to hard X-ray (380 KeV). Cadmium Zinc Telluride Imager (CZTI), one of the five instruments is a hard X-ray telescope functional over an energy range of 20-380 KeV. We aim to estimate the timing offset introduced in the data acquisition pipeline of the instrument, which will help in time alignment of high energy time series with those from two other ground-based observatories, viz. the Giant Meterwave Radio Telescope (GMRT) and the Ooty Radio Telescope (ORT). PSR B0531+21 is a well-studied pulsar with nearly aligned radio and hard X-ray pulse profiles. We use simultaneous observations of this pulsar with the ASTROSAT, the ORT and the GMRT. The pulsar was especially observed using the ORT with almost daily cadence to obtain good timing solutions. We also supplement the ORT data with archival FERMI data for estimation of timing noise. The timing offset of ASTROSAT instruments was estimated from fits to arrival time data at the ASTROSAT and the radio observatories. We estimate the offset between the GMRT and the ASTROSAT-CZTI to be -4716 $pm$ 50 $mu s$. The corresponding offset with the ORT was -29639 $pm$ 50 $mu s$. The offsets between the GMRT and Fermi-LAT -5368 $pm$ 56 $mu s$. (Abridged)
The Mid-Infrared Instrument (MIRI) Medium Resolution Spectrometer (MRS) is the only mid-IR Integral Field Spectrometer on board James Webb Space Telescope. The complexity of the MRS requires a very specialized pipeline, with some specific steps not p resent in other pipelines of JWST instruments, such as fringe corrections and wavelength offsets, with different algorithms for point source or extended source data. The MRS pipeline has also two different variants: the baseline pipeline, optimized for most foreseen science cases, and the optimal pipeline, where extra steps will be needed for specific science cases. This paper provides a comprehensive description of the MRS Calibration Pipeline from uncalibrated slope images to final scientific products, with brief descriptions of its algorithms, input and output data, and the accessory data and calibration data products necessary to run the pipeline.
We investigate the absolute calibration of the EUV Imaging Spectrometer (EIS) on Hinode by comparing EIS full-disk mosaics with irradiance observations from the EUV Variability Experiment (EVE) on the Solar Dynamics Observatory. We also use ultra-dee p (>10^5s) exposures of the quiet corona above the limb combined with a simple differential emission measure model to establish new effective area curves that incorporate information from the most recent atomic physics calculations. We find that changes to the EIS instrument sensitivity are a complex function of both time and wavelength. We find that the sensitivity is decaying exponentially with time and that the decay constants vary with wavelength. The EIS short wavelength channel shows significantly longer decay times than the long wavelength channel.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا