ترغب بنشر مسار تعليمي؟ اضغط هنا

Comparison of simulated backgrounds with in-orbit observations for HE, ME and LE onboard Insight-HXMT

77   0   0.0 ( 0 )
 نشر من قبل Juan Zhang
 تاريخ النشر 2020
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

Insight-HXMT, the first X-ray astronomical satellite in China, aims to reveal new sources in the Galaxy and to study fundamental physics of X-ray binaries from 1,keV to 250,keV. It has three collimated telescopes, the High Energy X-ray telescope (HE), the Medium Energy X-ray telescope (ME) and the Low Energy X-ray telescope (LE). Before the launch, in-orbit backgrounds of these three telescopes had been estimated through Geant4 simulation, in order to investigate the instrument performance and the achievement of scientific goals. In this work, these simulated backgrounds are compared with in-orbit observations. Good agreement is shown for all three telescopes. For HE, 1) the deviation of the simulated background rate after two years of operation in space is $sim5%$ from the observation; 2) the total background spectrum and the relative abundance of the $sim$67,keV line show long-term increases both in simulations and observations. For ME, 1) the deviation of simulated background rate is within $sim15%$ from the observation, and 2) there are no obvious long-term increase features in the background spectra of simulations and observations. For LE, the background level given by simulations is also consistent with observations. The consistencies of these comparisons validate that the Insight-HXMT mass model, i.e. space environment components and models adopted, physics processes selected and detector constructions built, is reasonable. However, the line features at $sim$7.5,keV and 8.0,keV, which are obvious in the observed spectra of LE, are not evident in simulations. This might result from uncertainties in the LE constructions.



قيم البحث

اقرأ أيضاً

373 - Xuelei Cao 2019
The Medium Energy X-ray telescope (ME) is one of the three main telescopes on board the Insight Hard X-ray Modulation Telescope (Insight-HXMT) astronomy satellite. ME contains 1728 pixels of Si-PIN detectors sensitive in 5-30 keV with a total geometr ical area of 952 cm2. Application Specific Integrated Circuit (ASIC) chips, VA32TA6, is used to achieve low power consumption and low readout noise. The collimators define three kinds of field of views (FOVs) for the telescope, 1{deg}{times}4{deg}, 4{deg}{times}4{deg}, and blocked ones. Combination of such FOVs can be used to estimate the in-orbit X-ray and particle background components. The energy resolution of ME is ~3 keV at 17.8 keV (FWHM) and the time resolution is 255 {mu}s. In this paper, we introduce the design and performance of ME.
107 - Yong Chen , WeiWei Cui , Wei Li 2019
The low energy (LE) X-ray telescope is one of the three main instruments of the Insight-Hard X-ray Modulation Telescope (Insight-HXMT). It is equipped with Swept Charge Device (SCD) sensor arrays with a total geometrical area of 384 cm2 and an energy band from 0.7 keV to 13 keV. In order to evaluate the particle induced X-ray background and the cosmic X-ray background simultaneously, LE adopts collimators to define four types of Field Of Views (FOVs). LE is constituted of three detector boxes (LEDs) and an electric control box (LEB) and achieves a good energy resolution of 140 eV at 5.9 keV, an excellent time resolution of 0.98 ms, as well as an extremely low pileup (<1% at 18000 cts/s). Detailed performance tests and calibration on the ground have been performed, including energy-channel relation, energy response, detection efficiency and time response.
77 - C.Z. Liu , Y.F. Zhang , X.F. Li 2019
The Insight-Hard X-ray Modulation Telescope (Insight-HXMT) is a broad band X-ray and gamma-ray (1-3000 keV) astronomy satellite. The High Energy X-ray telescope (HE) is one of its three main telescopes. The main detector plane of HE is composed of 18 NaI(Tl)/CsI(Na) phoswich detectors, where NaI(Tl) serves as primary detector to measure ~ 20-250 keV photons incident from the field of view (FOV) defined by the collimators, and CsI(Na) is used as an active shield detector to NaI(Tl) by pulse shape discrimination. CsI(Na) is also used as an omnidirectional gamma-ray monitor. The HE collimators have a diverse FOV: 1.1{deg}x 5.7{deg} (15 units), 5.7{deg}x 5.7{deg} (2 units) and blocked (1 unit), thus the combined FOV of HE is about 5.7{deg}x 5.7{deg}. Each HE detector has a diameter of 190 mm, resulting in the total geometrical area of about 5100 cm_2. The energy resolution is ~15% at 60 keV. The timing accuracy is better than 10 {mu}s and dead-time for each detector is less than 10 {mu}s. HE is devoted to observe the spectra and temporal variability of X-ray sources in the 20-250 keV band either by pointing observations for known sources or scanning observations to unveil new sources, and to monitor the gamma-ray sky in 0.2-3 MeV. This paper presents the design and performance of the HE instruments. Results of the on-ground calibration experiments are also reported.
LE is the low energy telescope of Insight-HXMT. It uses swept charge devices (SCDs) to detect soft X-ray photons. The time response of LE is caused by the structure of SCDs. With theoretical analysis and Monte Carlo simulations we discuss the influen ce of LE time response (LTR) on the timing analysis from three aspects: the power spectral density, the pulse profile and the time lag. After the LTR, the value of power spectral density monotonously decreases with the increasing frequency. The power spectral density of a sinusoidal signal reduces by a half at frequency 536 Hz. The corresponding frequency for QPO signals is 458 Hz. The Root mean square (RMS) of QPOs holds the similar behaviour. After the LTR, the centroid frequency and full width at half maxima (FWHM) of QPOs signals do not change. The LTR reduces the RMS of pulse profiles and shifts the pulse phase. In the time domain, the LTR only reduces the peak value of the crosscorrelation function while it does not change the peak position. Thus it will not affect the result of the time lag. When considering the time lag obtained from two instruments and one among them is LE, a 1.18 ms lag is expected caused by the LTR. The time lag calculated in the frequency domain is the same as that in the time domain.
In this work, we report the in-orbit demonstration of X-ray pulsar navigation with Insight-Hard X-ray Modulation Telescope (Insight-HXMT), which was launched on Jun. 15th, 2017. The new pulsar navigation method Significance Enhancement of Pulse-profi le with Orbit-dynamics (SEPO) is adopted to determine the orbit with observations of only one pulsar. In this test, the Crab pulsar is chosen and observed by Insight-HXMT from Aug. 31th to Sept. 5th in 2017. Using the 5-day-long observation data, the orbit of Insight-HXMT is determined successfully with the three telescopes onboard - High Energy X-ray Telescope (HE), Medium Energy X-ray Telescope (ME) and Low Energy X-ray Telescope (LE) - respectively. Combining all the data, the position and velocity of the Insight-HXMT are pinpointed to within 10 km (3 sigma) and 10 m/s (3 sigma), respectively.